220 research outputs found

    A General Analytical Approximation to Impulse Response of 3-D Microfluidic Channels in Molecular Communication

    Get PDF
    In this paper, the impulse response for a 3-D microfluidic channel in the presence of Poiseuille flow is obtained by solving the diffusion equation in radial coordinates. Using the radial distribution, the axial distribution is then approximated accordingly. Since Poiseuille flow velocity changes with radial position, molecules have different axial properties for different radial distributions. We, therefore, present a piecewise function for the axial distribution of the molecules in the channel considering this radial distribution. Finally, we lay evidence for our theoretical derivations for impulse response of the microfluidic channel and radial distribution of molecules through comparing them using various Monte Carlo simulations.Comment: The manuscript is submitted to IEEE: Transactions on Nanobioscienc

    Analytical Derivation of the Impulse Response for the Bounded 2-D Diffusion Channel

    Get PDF
    This paper focuses on the derivation of the distribution of diffused particles absorbed by an agent in a bounded environment. In particular, we analogously consider to derive the impulse response of a molecular communication channel in 2-D and 3-D environment. In 2-D, the channel involves a point transmitter that releases molecules to a circular absorbing receiver that absorbs incoming molecules in an environment surrounded by a circular reflecting boundary. Considering this setup, the joint distribution of the molecules on the circular absorbing receiver with respect to time and angle is derived. Using this distribution, the channel characteristics are examined. Furthermore, we also extend this channel model to 3-D using a cylindrical receiver and investigate the channel properties. We also propose how to obtain an analytical solution for the unbounded 2-D channel from our derived solutions, as no analytical derivation for this channel is present in the literature.Comment: 13 pages and 5 figure

    Modeling convection-diffusion-reaction systems for microfluidic molecular communications with surface-based receivers in Internet of Bio-Nano Things.

    Get PDF
    We consider a microfluidic molecular communication (MC) system, where the concentration-encoded molecular messages are transported via fluid flow-induced convection and diffusion, and detected by a surface-based MC receiver with ligand receptors placed at the bottom of the microfluidic channel. The overall system is a convection-diffusion-reaction system that can only be solved by numerical methods, e.g., finite element analysis (FEA). However, analytical models are key for the information and communication technology (ICT), as they enable an optimisation framework to develop advanced communication techniques, such as optimum detection methods and reliable transmission schemes. In this direction, we develop an analytical model to approximate the expected time course of bound receptor concentration, i.e., the received signal used to decode the transmitted messages. The model obviates the need for computationally expensive numerical methods by capturing the nonlinearities caused by laminar flow resulting in parabolic velocity profile, and finite number of ligand receptors leading to receiver saturation. The model also captures the effects of reactive surface depletion layer resulting from the mass transport limitations and moving reaction boundary originated from the passage of finite-duration molecular concentration pulse over the receiver surface. Based on the proposed model, we derive closed form analytical expressions that approximate the received pulse width, pulse delay and pulse amplitude, which can be used to optimize the system from an ICT perspective. We evaluate the accuracy of the proposed model by comparing model-based analytical results to the numerical results obtained by solving the exact system model with COMSOL Multiphysics

    Modeling duct flow for molecular communication

    Get PDF
    Active transport such as fluid flow is sought in molecular communication to extend coverage, improve reliability, and mitigate interference. Flow models are often over-simplified, assuming one-dimensional diffusion with constant drift. However, diffusion and flow are usually encountered in three-dimensional bounded environments where the flow is highly non-uniform such as in blood vessels or microfluidic channels. For a qualitative understanding of the relevant physical effects inherent to these channels, based on the Peclet number and the transmitter-receiver distance, we study when simplified models of uniform flow and advection-only transport are applicable. For these two regimes, analytical expressions for the channel impulse response are derived and validated by particle-based simulation. Furthermore, as advection-only transport is typically overlooked and hence not analyzed in the molecular communication literature, we evaluate the symbol error rate for exemplary on-off keying as performance metric

    A comprehensive survey of recent advancements in molecular communication

    Get PDF
    With much advancement in the field of nanotechnology, bioengineering and synthetic biology over the past decade, microscales and nanoscales devices are becoming a reality. Yet the problem of engineering a reliable communication system between tiny devices is still an open problem. At the same time, despite the prevalence of radio communication, there are still areas where traditional electromagnetic waves find it difficult or expensive to reach. Points of interest in industry, cities, and medical applications often lie in embedded and entrenched areas, accessible only by ventricles at scales too small for conventional radio waves and microwaves, or they are located in such a way that directional high frequency systems are ineffective. Inspired by nature, one solution to these problems is molecular communication (MC), where chemical signals are used to transfer information. Although biologists have studied MC for decades, it has only been researched for roughly 10 year from a communication engineering lens. Significant number of papers have been published to date, but owing to the need for interdisciplinary work, much of the results are preliminary. In this paper, the recent advancements in the field of MC engineering are highlighted. First, the biological, chemical, and physical processes used by an MC system are discussed. This includes different components of the MC transmitter and receiver, as well as the propagation and transport mechanisms. Then, a comprehensive survey of some of the recent works on MC through a communication engineering lens is provided. The paper ends with a technology readiness analysis of MC and future research directions

    Frequency-Domain Model of Microfluidic Molecular Communication Channels with Graphene BioFET-based Receivers

    Full text link
    Molecular Communication (MC) is a bio-inspired communication paradigm utilizing molecules for information transfer. Research on this unconventional communication technique has recently started to transition from theoretical investigations to practical testbed implementations, primarily harnessing microfluidics and sensor technologies. Developing accurate models for input-output relationships on these platforms, which mirror real-world scenarios, is crucial for assessing modulation and detection techniques, devising optimized MC methods, and understanding the impact of physical parameters on performance. In this study, we consider a practical microfluidic MC system equipped with a graphene field effect transistor biosensor (bioFET)-based MC receiver as the model system, and develop an analytical end-to-end frequency-domain model. The model provides practical insights into the dispersion and distortion of received signals, thus potentially informing the design of new frequency-domain MC techniques, such as modulation and detection methods. The accuracy of the developed model is verified through particle-based spatial stochastic simulations of pulse transmission in microfluidic channels and ligand-receptor binding reactions on the receiver surface

    Stable distributions as noise models for molecular communication

    Get PDF
    In this work, we consider diffusion-based molecular communication timing channels. Three different timing channels are presented based on three different modulation techniques, i.e., i) modulation of the release timing of the information particles, ii) modulation on the time between two consecutive information particles of the same type, and iii) modulation on the time between two consecutive information particles of different types. We show that each channel can be represented as an additive noise channel, where the noise follows one of the subclasses of stable distributions. We provide expressions for the probability density function of the noise terms, and numerical evaluations for the probability density function and cumulative density function. We also show that the tails are longer than Gaussian distribution, as expected
    • …
    corecore