24,875 research outputs found
Calibrating CHIME, A New Radio Interferometer to Probe Dark Energy
The Canadian Hydrogen Intensity Mapping Experiment (CHIME) is a transit
interferometer currently being built at the Dominion Radio Astrophysical
Observatory (DRAO) in Penticton, BC, Canada. We will use CHIME to map neutral
hydrogen in the frequency range 400 -- 800\,MHz over half of the sky, producing
a measurement of baryon acoustic oscillations (BAO) at redshifts between 0.8 --
2.5 to probe dark energy. We have deployed a pathfinder version of CHIME that
will yield constraints on the BAO power spectrum and provide a test-bed for our
calibration scheme. I will discuss the CHIME calibration requirements and
describe instrumentation we are developing to meet these requirements
Recommended from our members
The decay of space charge in a glassy epoxy resin following voltage removal
The PEA technique is used to measure the distribution of space charge in an epoxy resin after polarisation for one week at an applied field of 7.14kV/mm over a range of temperatures. The decay of the space charge is followed for times up to 114 hours after removal of the voltage and analysed in terms of a number of alternative decay mechanisms. It is shown that the rate-determining stage of the decay mechanism is that of a thermally activated process that has been associated with charge de-trapping. At times greater than 102s the de-trapping process behaves as though the space charge field does not exist and the retention time of the space charge depends only upon the depth of the deepest occupied traps and the temperature
Electron electric dipole moment experiment using electric-field quantized slow cesium atoms
A proof-of-principle electron electric dipole moment (e-EDM) experiment using
slow cesium atoms, nulled magnetic fields, and electric field quantization has
been performed. With the ambient magnetic fields seen by the atoms reduced to
less than 200 pT, an electric field of 6 MV/m lifts the degeneracy between
states of unequal mF and, along with the low (approximately 3 m/s) velocity,
suppresses the systematic effect from the motional magnetic field. The low
velocity and small residual magnetic field have made it possible to induce
transitions between states and to perform state preparation, analysis, and
detection in regions free of applied static magnetic and electric fields. This
experiment demonstrates techniques that may be used to improve the e-EDM limit
by two orders of magnitude, but it is not in itself a sensitive e-EDM search,
mostly due to limitations of the laser system.Comment: 9 pages, 8 figures, accepted for publication in Phys. Rev.
Recommended from our members
Electric field requirements for charge packet generation and movement in XLPE
The formation of space charge packets in XLPE (Cross-linked polyethylene) tapes from unaged cable insulation has been studied utilising the pulsed electro-acoustic (PEA) technique. The 150 m thick sheets were studied under constant applied dc field of 120 kV/mm at a temperature of 20 C for a period of 48 hours. After an inception period of about 3.5 hours, during which heterocharge accumulates at the anode and increases the local field there, a sequence of positive charge packets were observed to transit the sample starting from near the anode. Calculation of the internal field showed that the packets required a field of 140 kV/mm for their initiation. Reduction of the applied field step-wise from 120 kV/mm to 80 kV/mm indicated that the charge packet would keep moving as long as the local field at its front exceeded 100 kV/mm, but with a reducing magnitude. A return to an applied field of 120 kV/mm confirmed that the local field required to initiate a new packet was in excess of 135 kV/mm. The results are discussed in terms of current theories of charge packet formation. The first packet appears to be a moving front of field ionisation. The generation of subsequent packets is governed by the field at the anode and the balance of charge injection and extraction process, which occur there. The nature of the negative charges produced at the ionisation front is not clear, but they are unlikely to be electrons
Development of a custom on-line ultrasonic vapour analyzer/flowmeter for the ATLAS inner detector, with application to gaseous tracking and Cherenkov detectors
Precision sound velocity measurements can simultaneously determine binary gas
composition and flow. We have developed an analyzer with custom electronics,
currently in use in the ATLAS inner detector, with numerous potential
applications. The instrument has demonstrated ~0.3% mixture precision for
C3F8/C2F6 mixtures and < 10-4 resolution for N2/C3F8 mixtures. Moderate and
high flow versions of the instrument have demonstrated flow resolutions of +/-
2% F.S. for flows up to 250 l.min-1, and +/- 1.9% F.S. for linear flow
velocities up to 15 ms-1; the latter flow approaching that expected in the
vapour return of the thermosiphon fluorocarbon coolant recirculator being built
for the ATLAS silicon tracker.Comment: Paper submitted to TWEPP2012; Topical Workshop on Electronics for
Particle Physics, Oxford, UK, September 17-21, 2012. KEYWORDS: Sonar;
Saturated fluorocarbons; Flowmetry; Sound velocity, Gas mixture analysis. 8
pages, 7 figure
NASA Thesaurus Supplement: A three part cumulative supplement to the 1982 edition of the NASA Thesaurus (supplement 3)
The three part cumulative NASA Thesaurus Supplement to the 1982 edition of the NASA Thesaurus includes Part 1, Hierarchical Listing, Part 2, Access Vocabulary, and Part 3, Deletions. The semiannual supplement gives complete hierarchies for new terms and includes new term indications for entries new to this supplement
- …