Model Predictive Control (MPC) for Enhancing Building and HVAC System Energy Efficiency: Problem Formulation, Applications and Opportunities
In the last few years, the application of Model Predictive Control (MPC) for energy management in buildings has received significant attention from the research community. MPC is becoming more and more viable because of the increase in computational power of building automation systems and the availability of a significant amount of monitored building data. MPC has found successful implementation in building thermal regulation, fully exploiting the potential of building thermal mass. Moreover, MPC has been positively applied to active energy storage systems, as well as to the optimal management of on-site renewable energy sources. MPC also opens up several opportunities for enhancing energy efficiency in the operation of Heating Ventilation and Air Conditioning (HVAC) systems because of its ability to consider constraints, prediction of disturbances and multiple conflicting objectives, such as indoor thermal comfort and building energy demand. Despite the application of MPC algorithms in building control has been thoroughly investigated in various works, a unified framework that fully describes and formulates the implementation is still lacking. Firstly, this work introduces a common dictionary and taxonomy that gives a common ground to all the engineering disciplines involved in building design and control. Secondly the main scope of this paper is to define the MPC formulation framework and critically discuss the outcomes of different existing MPC algorithms for building and HVAC system management. The potential benefits of the application of MPC in improving energy efficiency in buildings were highlighted
Buildings-to-Grid Integration Framework
This paper puts forth a mathematical framework for Buildings-to-Grid (BtG)
integration in smart cities. The framework explicitly couples power grid and
building's control actions and operational decisions, and can be utilized by
buildings and power grids operators to simultaneously optimize their
performance. Simplified dynamics of building clusters and building-integrated
power networks with algebraic equations are presented---both operating at
different time-scales. A model predictive control (MPC)-based algorithm that
formulates the BtG integration and accounts for the time-scale discrepancy is
developed. The formulation captures dynamic and algebraic power flow
constraints of power networks and is shown to be numerically advantageous. The
paper analytically establishes that the BtG integration yields a reduced total
system cost in comparison with decoupled designs where grid and building
operators determine their controls separately. The developed framework is
tested on standard power networks that include thousands of buildings modeled
using industrial data. Case studies demonstrate building energy savings and
significant frequency regulation, while these findings carry over in network
simulations with nonlinear power flows and mismatch in building model
parameters. Finally, simulations indicate that the performance does not
significantly worsen when there is uncertainty in the forecasted weather and
base load conditions.Comment: In Press, IEEE Transactions on Smart Gri
Innovative solar energy technologies and control algorithms for enhancing demand-side management in buildings
The present thesis investigates innovative energy technologies and control algorithms for enhancing demand-side management in buildings. The work focuses on an innovative low-temperature solar thermal system for supplying space heating demand of buildings. This technology is used as a case study to explore possible solutions to fulfil the mismatch between energy production and its exploitation in building. This shortcoming represents the primary issue of renewable energy sources. Technologies enhancing the energy storage capacity and active demand-side management or demand-response strategies must be implemented in buildings. For these purposes, it is possible to employ hardware or software solutions. The hardware solutions for thermal demand response of buildings are those technologies that allow the energy loads to be permanently shifted or mitigated. The software solutions for demand response are those that integrate an intelligent supervisory layer in the building automation (or management) systems. The present thesis approaches the problem from both the hardware technologies side and the software solutions side. This approach enables the mutual relationships and interactions between the strategies to be appropriately measured.
The thesis can be roughly divided in two parts. The first part of the thesis focuses on an innovative solar thermal system exploiting a novel heat transfer fluid and storage media based on micro-encapsulated Phase Change Material slurry. This material leads the system to enhance latent heat exchange processes and increasing the overall performance. The features of Phase Change Material slurry are investigated experimentally and theoretically. A full-scale prototype of this innovative solar system enhancing latent heat exchange is conceived, designed and realised. An experimental campaign on the prototype is used to calibrate and validate a numerical model of the solar thermal system. This model is developed in this thesis to define the thermo-energetic behaviour of the technology. It consists of two mathematical sub-models able to describe the power/energy balances of the flat-plate solar thermal collector and the thermal energy storage unit respectively. In closed-loop configuration, all the Key Performance Indicators used to assess the reliability of the model indicate an excellent comparison between the system monitored outputs and simulation results. Simulation are performed both varying parametrically the boundary condition and investigating the long-term system performance in different climatic locations. Compared to a traditional water-based system used as a reference baseline, the simulation results show that the innovative system could improve the production of useful heat up to 7 % throughout the year and 19 % during the heating season.
Once the hardware technology has been defined, the implementation of an innovative control method is necessary to enhance the operational efficiency of the system. This is the primary focus of the second part of the thesis. A specific solution is considered particularly promising for this purpose: the adoption of Model Predictive Control (MPC) formulations for improving the system thermal and energy management. Firstly, this thesis provides a robust and complete framework of the steps required to define an MPC problem for building processes regulation correctly. This goal is reached employing an extended review of the scientific literature and practical application concerning MPC application for building management. Secondly, an MPC algorithm is formulated to regulate the full-scale solar thermal prototype. A testbed virtual environment is developed to perform closed-loop simulations. The existing rule-based control logic is employed as the reference baseline. Compared to the baseline, the MPC algorithm produces energy savings up to 19.2 % with lower unmet energy demand
Model-predictive control for non-domestic buildings: a critical review and prospects
Model-predictive control (MPC) has recently excited a great deal of interest as a new control paradigm for non-domestic buildings. Since it is based on the notion of optimisation, MPC is, in principle, well-placed to deliver significant energy savings and reduction in carbon emissions compared to existing rule-based control systems. In this paper, we critically review the prospects for buildings MPC and, in particular, the central role of the predictive mathematical model that lies at its heart; our clear emphasis is on practical implementation rather than control-theoretic aspects, and covers the role of occupants as well as the form of the predictive model. The most appropriate structure for such a model is still an open question, which we discuss alongside the development of the initial model, and the process of updating the model during the building’s operational life. The importance of sensor placement is highlighted alongside the possibility of updating the model with occupants’ comfort perception. We conclude that there is an urgent need for research on the automated creation and updating of predictive models if MPC is to become an economically-viable control methodology for non-domestic buildings. Finally, more evidence through operating full scale buildings with MPC is required to demonstrate the viability of this method
- …