144,731 research outputs found

    Criteria for the use of omics-based predictors in clinical trials.

    Get PDF
    The US National Cancer Institute (NCI), in collaboration with scientists representing multiple areas of expertise relevant to 'omics'-based test development, has developed a checklist of criteria that can be used to determine the readiness of omics-based tests for guiding patient care in clinical trials. The checklist criteria cover issues relating to specimens, assays, mathematical modelling, clinical trial design, and ethical, legal and regulatory aspects. Funding bodies and journals are encouraged to consider the checklist, which they may find useful for assessing study quality and evidence strength. The checklist will be used to evaluate proposals for NCI-sponsored clinical trials in which omics tests will be used to guide therapy

    Direct detection and characterization of foot-and-mouth disease virus in East Africa using a field-ready real-time PCR platform

    Get PDF
    Effective control and monitoring of foot-and-mouth disease (FMD) relies upon rapid and accurate disease confirmation. Currently, clinical samples are usually tested in reference laboratories using standardized assays recommended by The World Organisation for Animal Health (OIE). However, the requirements for prompt and serotype-specific diagnosis during FMD outbreaks, and the need to establish robust laboratory testing capacity in FMD-endemic countries have motivated the development of simple diagnostic platforms to support local decision-making. Using a portable thermocycler, the T-COR™ 8, this study describes the laboratory and field evaluation of a commercially available, lyophilized pan-serotype-specific real-time RT-PCR (rRT-PCR) assay and a newly available FMD virus (FMDV) typing assay (East Africa-specific for serotypes: O, A, Southern African Territories [SAT] 1 and 2). Analytical sensitivity, diagnostic sensitivity and specificity of the pan-serotype-specific lyophilized assay were comparable to that of an OIE-recommended laboratory-based rRT-PCR (determined using a panel of 57 FMDV-positive samples and six non-FMDV vesicular disease samples for differential diagnosis). The FMDV-typing assay was able to correctly identify the serotype of 33/36 FMDV-positive samples (no cross-reactivity between serotypes was evident). Furthermore, the assays were able to accurately detect and type FMDV RNA in multiple sample types, including epithelial tissue suspensions, serum, oesophageal–pharyngeal (OP) fluid and oral swabs, both with and without the use of nucleic acid extraction. When deployed in laboratory and field settings in Tanzania, Kenya and Ethiopia, both assays reliably detected and serotyped FMDV RNA in samples (n = 144) collected from pre-clinical, clinical and clinically recovered cattle. These data support the use of field-ready rRT-PCR platforms in endemic settings for simple, highly sensitive and rapid detection and/or characterization of FMDV

    Performance analysis of anaplasma antibody competitive ELISA using the ROC curve for screening of anaplasmosis in camel populations in Egypt

    Get PDF
    Anaplasmosis is a tick-born and potential zoonotic disease caused by Anaplasma (A.) phagocytophilum, A. ovis, A. platys and A. capra. Anaplasma marginale affecting bovines and camels causing significant economic losses. Camels as an integral part of the socio-economic lifestyle of nomads in semi-arid to arid ecosystems are prone to suffer from subclinical Anaplasma infections. This study aimed to determine the performance and adaptation of commercial competitive Anaplasma ELISA (cELISA) as a tool for screening the seroprevalence of anaplasmosis whitin the camel populations in Egypt. This study was based on the serological investigation of 437 camel sera collected between 2015 and 2016 during a Q fever prevalence study in Egypt using commercially available cELISA for the detection of antibodies specific for Anaplasma in bovine serum. The receiver operating characteristic (ROC) curve, an analysis method for optimizing cutoff values in cELISAs, was used to estimate the sensitivity and specificity using 76 true as serological positive (n = 7) and negative (n = 60) for Anaplasma antibodies. ROC curve analysis was done for 7 true positive and 60 true negative bovine samples and 7 true positive and 29 true negative camel samples serum. Real time PCR and/or conventional PCR was applied to confirm Anaplasma spp. specific-DNA in camel serum as an indication of a true positive and true negative for ROC analysis. Chi square analysis was performed to estimate the association between risk factors and anaplasmosis in camels. The cutoff value was determined as 0.42 (p value ≤ 0.001). Data simulation with randomly generated values revealed a cutoff value of 0.417 (p ≤ 0.001) with resulting 58.1% Se and 97.8% Sp. Seven true positive and 29 true negative camel serum samples was confirmed by PCR. Using the estimated cut off, the seroprevalence in the Nile Valley and Delta and the Eastern Desert domain was 47.4% and 46.4%, respectively. The potential risk factors as domains and origin of animals were less significantly associated with the prevalence of anaplasmosis (domains: χ(2) = 41.8, p value ≤ 0.001 and origin: χ(2) = 42.56, p value ≤ 0.001). Raising awareness especially for veterinarians and animal owners will significantly contribute to the best understanding of anaplasmosis in camels in Egypt. Alternative (in silico) validation techniques and preliminary prevalence studies are mandatory towards the control of neglected anaplasmosis in the camel population

    Clinical Performance of an Automated Reader in Interpreting Malaria Rapid Diagnostic Tests in Tanzania.

    Get PDF
    Parasitological confirmation of malaria is now recommended in all febrile patients by the World Health Organization (WHO) to reduce inappropriate use of anti-malarial drugs. Widespread implementation of rapid diagnostic tests (RDTs) is regarded as an effective strategy to achieve this goal. However, the quality of diagnosis provided by RDTs in remote rural dispensaries and health centres is not ideal. Feasible RDT quality control programmes in these settings are challenging. Collection of information regarding diagnostic events is also very deficient in low-resource countries. A prospective cohort of consecutive patients aged more than one year from both genders, seeking routine care for febrile episodes at dispensaries located in the Bagamoyo district of Tanzania, were enrolled into the study after signing an informed consent form. Blood samples were taken for thick blood smear (TBS) microscopic examination and malaria RDT (SD Bioline Malaria Antigen Pf/PanTM (SD RDT)). RDT results were interpreted by both visual interpretation and DekiReaderTM device. Results of visual interpretation were used for case management purposes. Microscopy was considered the "gold standard test" to assess the sensitivity and specificity of the DekiReader interpretation and to compare it to visual interpretation. In total, 1,346 febrile subjects were included in the final analysis. The SD RDT, when used in conjunction with the DekiReader and upon visual interpretation, had sensitivities of 95.3% (95% CI, 90.6-97.7) and 94.7% (95% CI, 89.8--97.3) respectively, and specificities of 94.6% (95% CI, 93.5--96.1) and 95.6% (95% CI, 94.2--96.6), respectively to gold standard. There was a high percentage of overall agreement between the two methods of interpretation. The sensitivity and specificity of the DekiReader in interpretation of SD RDTs were comparable to previous reports and showed high agreement to visual interpretation (>98%). The results of the study reflect the situation in real practice and show good performance characteristics of DekiReader on interpreting malaria RDTs in the hands of local laboratory technicians. They also suggest that a system like this could provide great benefits to the health care system. Further studies to look at ease of use by community health workers, and cost benefit of the system are warranted

    Biological and technical variables affecting immunoassay recovery of cytokines from human serum and simulated vaginal fluid: A multicenter study

    Get PDF
    The increase of proinflammatory cytokines in vaginal secretions may serve as a surrogate marker of unwanted inflammatory reaction to microbicide products topically applied for the prevention of sexually transmitted diseases, including HIV-1. Interleukin (IL)-1β and IL-6 have been proposed as indicators of inflammation and increased risk of HIV-1 transmission; however, the lack of information regarding detection platforms optimal for vaginal fluids and interlaboratory variation limit their use for microbicide evaluation and other clinical applications. This study examines fluid matrix variants relevant to vaginal sampling techniques and proposes a model for interlaboratory comparisons across current cytokine detection technologies. IL-1β and IL-6 standards were measured by 12 laboratories in four countries, using 14 immunoassays and four detection platforms based on absorbance, chemiluminescence, electrochemiluminescence, and fluorescence. International reference preparations of cytokines with defined biological activity were spiked into (1) a defined medium simulating the composition of human vaginal fluid at pH 4.5 and 7.2, (2) physiologic salt solutions (phosphate-buffered saline and saline) commonly used for vaginal lavage sampling in clinical studies of cytokines, and (3) human blood serum. Assays were assessed for reproducibility, linearity, accuracy, and significantly detectable fold difference in cytokine level. Factors with significant impact on cytokine recovery were determined by Kruskal−Wallis analysis of variance with Dunn’s multiple comparison test and multiple regression models. All assays showed acceptable intra-assay reproducibility; however, most were associated with significant interlaboratory variation. The smallest reliably detectable cytokine differences (P < 0.05) derived from pooled interlaboratory data varied from 1.5- to 26-fold depending on assay, cytokine, and matrix type. IL-6 but not IL-1β determinations were lower in both saline and phosphate-buffered saline as compared to vaginal fluid matrix, with no significant effect of pH. The (electro)chemiluminescence-based assays were most discriminative and consistently detected <2-fold differences within each matrix type. The Luminex-based assays were less discriminative with lower reproducibility between laboratories. These results suggest the need for uniform vaginal sampling techniques and a better understanding of immunoassay platform differences and cross-validation before the biological significance of cytokine variations can be validated in clinical trials. This investigation provides the first standardized analytic approach for assessing differences in mucosal cytokine levels and may improve strategies for monitoring immune responses at the vaginal mucosal interface

    When the outcome is different than expected : subjective expectancy shapes reward prediction error at the FRN level

    Get PDF
    Converging evidence in human electrophysiology suggests that evaluative feedback provided during performance monitoring (PM) elicits two distinctive and successive ERP components: the feedback-related negativity (FRN) and the P3b. Whereas the FRN has previously been linked to reward prediction error (RPE), the P3b has been conceived as reflecting motivational or attentional processes following the early processing of the RPE, including action value updating. However, it remains unclear whether these two consecutive neurophysiological effects depend on the direction of the unexpectedness (better- or worse-than-expected outcomes; signed RPE) or instead only on the degree of unexpectedness irrespective of direction (i.e., unsigned RPE). To address this question, we devised an experiment in which we manipulated the objective reward probability and the subjective reward expectancy (via instructions) in a factorial within-subject design and explored amplitude changes of the FRN and the P3b. A 64-channel EEG was recorded while 32 participants performed a speeded go/no-go task in which evaluative feedback based on the reward probability either violated expectancy (thereby creating a RPE) or did not. This violation corresponded either to better- or worse-than-expected events. Results showed that the FRN was larger when RPE occurred than when it did not, but irrespective of the direction of this violation. Interestingly, in these two conditions, action value was updated for the positive feedback selectively, as shown by the P3b amplitude. These results obey a two-stage model of PM assuming that unsigned RPE is first rapidly detected (FRN level) before the positive feedback's value is updated selectively (P3b effect)

    Accurate molecular imaging of small animals taking into account animal models, handling, anaesthesia, quality control and imaging system performance

    Get PDF
    Small-animal imaging has become an important technique for the development of new radiotracers, drugs and therapies. Many laboratories have now a combination of different small-animal imaging systems, which are being used by biologists, pharmacists, medical doctors and physicists. The aim of this paper is to give an overview of the important factors in the design of a small animal, nuclear medicine and imaging experiment. Different experts summarize one specific aspect important for a good design of a small-animal experiment

    Home detection of freezing of gait using Support Vector Machines through a single waist-worn triaxial accelerometer

    Get PDF
    Among Parkinson’s disease (PD) symptoms, freezing of gait (FoG) is one of the most debilitating. To assess FoG, current clinical practice mostly employs repeated evaluations over weeks and months based on questionnaires, which may not accurately map the severity of this symptom. The use of a non-invasive system to monitor the activities of daily living (ADL) and the PD symptoms experienced by patients throughout the day could provide a more accurate and objective evaluation of FoG in order to better understand the evolution of the disease and allow for a more informed decision-making process in making adjustments to the patient’s treatment plan. This paper presents a new algorithm to detect FoG with a machine learning approach based on Support Vector Machines (SVM) and a single tri-axial accelerometer worn at the waist. The method is evaluated through the acceleration signals in an outpatient setting gathered from 21 PD patients at their home and evaluated under two different conditions: first, a generic model is tested by using a leave-one-out approach and, second, a personalised model that also uses part of the dataset from each patient. Results show a significant improvement in the accuracy of the personalised model compared to the generic model, showing enhancement in the specificity and sensitivity geometric mean (GM) of 7.2%. Furthermore, the SVM approach adopted has been compared to the most comprehensive FoG detection method currently in use (referred to as MBFA in this paper). Results of our novel generic method provide an enhancement of 11.2% in the GM compared to the MBFA generic model and, in the case of the personalised model, a 10% of improvement with respect to the MBFA personalised model. Thus, our results show that a machine learning approach can be used to monitor FoG during the daily life of PD patients and, furthermore, personalised models for FoG detection can be used to improve monitoring accuracy.Peer ReviewedPostprint (published version
    • …
    corecore