305 research outputs found

    Power System State Estimation and Renewable Energy Optimization in Smart Grids

    Get PDF
    The future smart grid will benefit from real-time monitoring, automated outage management, increased renewable energy penetration, and enhanced consumer involvement. Among the many research areas related to smart grids, this dissertation will focus on two important topics: power system state estimation using phasor measurement units (PMUs), and optimization for renewable energy integration. In the first topic, we consider power system state estimation using PMUs, when phase angle mismatch exists in the measurements. In particular, we build a measurement model that takes into account the measurement phase angle mismatch. We then propose algorithms to increase state estimation accuracy by taking into account the phase angle mismatch. Based on the proposed measurement model, we derive the posterior Cramér-Rao bound on the estimation error, and propose a method for PMU placement in the grid. Using numerical examples, we show that by considering the phase angle mismatch in the measurements, the estimation accuracy can be significantly improved compared with the traditional weighted least-squares estimator or Kalman filtering. We also show that using the proposed PMU placement strategy can increase the estimation accuracy by placing a limited number of PMUs in proper locations. In the second topic, we consider optimization for renewable energy integration in smart grids. We first consider a scenario where individual energy users own on-site renewable generators, and can both purchase and sell electricity to the main grid. Under this setup, we develop a method for parallel load scheduling of different energy users, with the goal of reducing the overall cost to energy users as well as to energy providers. The goal is achieved by finding the optimal load schedule of each individual energy user in a parallel distributed manner, to flatten the overall load of all the energy users. We then consider the case of a micro-grid, or an isolated grid, with a large penetration of renewable energy. In this case, we jointly optimize the energy storage and renewable generator capacity, in order to ensure an uninterrupted power supply with minimum costs. To handle the large dimensionality of the problem due to large historical datasets used, we reformulate the original optimization problem as a consensus problem, and use the alternating direction method of multipliers to solve for the optimal solution in a distributed manner

    Synchrophasor Based Islanding & Open phase fault Protection in Distribution Systems

    Get PDF
    With the rapid growth of renewable energy resources, energy efficiency initiatives, electric vehicles, energy storage, etc., distribution systems are becoming more complex such that conventional protection, control, and measurement infrastructure – typically concentrated at the main substation, with little to no access to information along the feeder – cannot maintain the reliability of the system without some sort of additional protection, control and measurement functionalities. As an example, a dedicated communication channel for carrying the transfer trip signal from the substation to the Point of Common Coupling (PCC) to prevent islanding operation of alternative resources, has been a requirement for many utilities. In the transformation of the distribution system from a simple radial system to a bidirectional energy flow network, integration of many intelligent devices and applications will also be required. Thus, this situation calls for investment in communication infrastructure, and augmentation of protection, control, and measurement functionalities. The value of power system communication technologies such as synchrophasor measurement technology – which includes the Phasor Measurement Unit (measuring and providing voltage and current phasors in the real time via communication), communication infrastructure, and Phasor Data Concentrator (PDC) – is being recognized through large-scale deployments around the world. However, these implementations are predominantly limited to some monitoring-type applications and are being realized primarily in transmission systems and bulk power systems (≥100 kV), where performance requirements are much more stringent compared to distribution systems. So contrary to transmission systems, the current status of synchrophasor measurement technology can be utilized to its full extent in distribution systems, as shown in current research for anti-islanding and open-phase faults in the distribution feeder protection application, where the number of PMUs and performance required is somewhat lower than the bulk of power energy. Thus, the opportunity to invest in the implementation of synchronized measurement technology in distribution system is timely as it can be coordinated with other investments in feeder modernization, distributed generation (DG) integration, and infrastructure enhancements that are underway, including “smart grid” initiatives. In the first use case of this research, the behavior of the major DG types during islanding is studied through accurate transient modeling of utility type distribution systems using PSCAD-EMTDC and MATLAB. The study proposes augmentation of PMU-based solutions to the current passive islanding protection elements, such as voltage and frequency, and improving the non-detection zone of the passive elements by adapting their settings based on normal loading conditions at closest known instant prior to the fault or islanding occurrence. The solution proposes a system architecture that requires one PMU at each PCC bus and in the main substation. The communication aspect is based on the IEC 6850-90-5 report, where the PMU can subscribe directly to the data stream of the remote PMUs such that the need for PDCs in this application is eliminated, yielding better performance. In the second use case, an open-phase fault – a major concern for distribution utilities from safety of public and equipment perspective – has been studied. Clearing the open-phase fault without identifying the type of fault could result in an attempt by the recloser to reenergize the downed wire; conversely, an undetected open-phase fault could initiate ferro-resonance, thereby stressing equipment and increasing the risk to public safety, both urban and rural. This work discusses comprehensive analysis of symmetrical components of various types of open-phase faults in the distribution feeder with the presence of distributed generators (DGs) and proposes the use of phasor measurement data located at substation and PCC to identify the open-phase fault. The proposed algorithm relies on the rate of change of the various current and voltage sequence components. In the study conducted, the utility type feeder and substation are modeled in PSCAD-EMTDC, and different types of open-phase fault and shunt faults are studied to verify the dependability and security of proposed algorithm

    Optimal Placement of Phasor Measurement Units for Power Systems Using Genetic Algorithm

    Get PDF
    Power grids require monitoring to operate with high efficiency while minimizing the chances of having a failure. However, current monitoring scheme which consists of SCADA (Supervisory Control and Data Acquisition), accompanied with conventional meters distributed throughout the grid, is no longer sufficient to maintain an acceptable operation of the grid. This is evident from the multiple failures and blackouts that happened and are still happening in grids worldwide. This issue became more severe due to systems being operated near their limits (to reduce costs and due to the increase in electricity demands), as well as, the addition of renewable energy sources, which usually have abrupt changes. Smart grids were introduced as a solution to this issue by the inclusion of Wide Area Monitoring System (WAMS), which is mainly based on Phasor Measurement Units (PMU), which are measurement devices that provides synchronized time stamped measurements with high sending rate which significantly improves the monitoring of the grid. However, PMUs are relatively expensive (considering both direct and indirect costs incurred). Thus, it is desired to know the minimum number of PMUs required for achieving certain monitoring criteria. Thus, Optimal PMU Placement (OPP) formulates an optimization problem to solve this issue. In the literature of OPP, multiple objectives and constraints are considered, based on desired criteria. In this thesis, a review of OPP is made, followed by the application of selected algorithms (Integer Linear Programming and Genetic Algorithm) on various test systems as a verification and then applying it to Qatar Grid, to compare between different considerations as well as gain insight about the possible PMU placements for Qatar Grid. The contribution of this thesis is introducing a modified fitness function for the Genetic Algorithm that provides more diverse results than previous papers, while incorporating for various considerations like Zero Injection Buses, Conventional Measurements and current branch limit. It also analyzes the results of current branch limit and provides new plots describing their effects

    Physics-Based and Data-Driven Analytics for Enhanced Planning and Operations in Power Systems with Deep Renewable Penetration

    Get PDF
    This dissertation is motivated by the lack of combined physics-based and data-driven framework for solving power system challenges that are introduced by the integration of new devices and new system components. As increasing number of stochastic generation, responsive loads, and dynamic measurements are involved in the planning and operations of modern power systems, utilities and system operators are in great need of new analysis framework that could combine physical models and measuring data together for solving challenging planning and operational problems. In view of the above challenges, the high-level objective of this dissertation is to develop a framework for integrating measurement data into large physical systems modeled by dynamical equations. To this end, the dissertation first identifies four critical tasks for the planning and operations of the modern power systems: the data collection and pre-processing, the system situational awareness, the decision making process, as well as the post-event analysis. The dissertation then takes one concrete application in each of these critical tasks as the example, and proposes the physics-based/data-driven approach for solving the challenging problems faced by this specific application. To this end, this dissertation focuses on solving the following specific problems using physics-based/data-driven approaches. First, for the data collection and pre-processing platform, a purely data-driven approach is proposed to detect bad metering data in the phasor measurement unit (PMU) monitoring systems, and ensure the overall PMU data quality. Second, for the situational awareness platform, a physics-based voltage stability assessment method is presented to improve the situational awareness of system voltage instabilities. Third, for the decision making platform, a combined physics-based and data-driven framework is proposed to support the decision making process of PMU-based power plant model validation. Forth, for the post-event analysis platform, a physics-based post-event analysis is presented to identify the root causes of the sub-synchronous oscillations induced by the wind farm integration. The above problems and proposed solutions are discussed in detail in Section 2 through Section 5. The results of this work can be integrated to address practical problems in modern power system planning and operations

    Wide-Area Time-Synchronized Closed-Loop Control of Power Systems And Decentralized Active Distribution Networks

    Get PDF
    The rapidly expanding power system grid infrastructure and the need to reduce the occurrence of major blackouts and prevention or hardening of systems against cyber-attacks, have led to increased interest in the improved resilience of the electrical grid. Distributed and decentralized control have been widely applied to computer science research. However, for power system applications, the real-time application of decentralized and distributed control algorithms introduce several challenges. In this dissertation, new algorithms and methods for decentralized control, protection and energy management of Wide Area Monitoring, Protection and Control (WAMPAC) and the Active Distribution Network (ADN) are developed to improve the resiliency of the power system. To evaluate the findings of this dissertation, a laboratory-scale integrated Wide WAMPAC and ADN control platform was designed and implemented. The developed platform consists of phasor measurement units (PMU), intelligent electronic devices (IED) and programmable logic controllers (PLC). On top of the designed hardware control platform, a multi-agent cyber-physical interoperability viii framework was developed for real-time verification of the developed decentralized and distributed algorithms using local wireless and Internet-based cloud communication. A novel real-time multiagent system interoperability testbed was developed to enable utility independent private microgrids standardized interoperability framework and define behavioral models for expandability and plug-and-play operation. The state-of-theart power system multiagent framework is improved by providing specific attributes and a deliberative behavior modeling capability. The proposed multi-agent framework is validated in a laboratory based testbed involving developed intelligent electronic device prototypes and actual microgrid setups. Experimental results are demonstrated for both decentralized and distributed control approaches. A new adaptive real-time protection and remedial action scheme (RAS) method using agent-based distributed communication was developed for autonomous hybrid AC/DC microgrids to increase resiliency and continuous operability after fault conditions. Unlike the conventional consecutive time delay-based overcurrent protection schemes, the developed technique defines a selectivity mechanism considering the RAS of the microgrid after fault instant based on feeder characteristics and the location of the IEDs. The experimental results showed a significant improvement in terms of resiliency of microgrids through protection using agent-based distributed communication

    Wide-area monitoring and control of future smart grids

    No full text
    Application of wide-area monitoring and control for future smart grids with substantial wind penetration and advanced network control options through FACTS and HVDC (both point-to-point and multi-terminal) is the subject matter of this thesis. For wide-area monitoring, a novel technique is proposed to characterize the system dynamic response in near real-time in terms of not only damping and frequency but also mode-shape, the latter being critical for corrective control action. Real-time simulation in Opal-RT is carried out to illustrate the effectiveness and practical feasibility of the proposed approach. Potential problem with wide-area closed-loop continuous control using FACTS devices due to continuously time-varying latency is addressed through the proposed modification of the traditional phasor POD concept introduced by ABB. Adverse impact of limited bandwidth availability due to networked communication is established and a solution using an observer at the PMU location has been demonstrated. Impact of wind penetration on the system dynamic performance has been analyzed along with effectiveness of damping control through proper coordination of wind farms and HVDC links. For multi-terminal HVDC (MTDC) grids the critical issue of autonomous power sharing among the converter stations following a contingency (e.g. converter outage) is addressed. Use of a power-voltage droop in the DC link voltage control loops using remote voltage feedback is shown to yield proper distribution of power mismatch according to the converter ratings while use of local voltages turns out to be unsatisfactory. A novel scheme for adapting the droop coefficients to share the burden according to the available headroom of each converter station is also studied. The effectiveness of the proposed approaches is illustrated through detailed frequency domain analysis and extensive time-domain simulation results on different test systems
    • …
    corecore