84,182 research outputs found
Registration of Standardized Histological Images in Feature Space
In this paper, we propose three novel and important methods for the
registration of histological images for 3D reconstruction. First, possible
intensity variations and nonstandardness in images are corrected by an
intensity standardization process which maps the image scale into a standard
scale where the similar intensities correspond to similar tissues meaning.
Second, 2D histological images are mapped into a feature space where continuous
variables are used as high confidence image features for accurate registration.
Third, we propose an automatic best reference slice selection algorithm that
improves reconstruction quality based on both image entropy and mean square
error of the registration process. We demonstrate that the choice of reference
slice has a significant impact on registration error, standardization, feature
space and entropy information. After 2D histological slices are registered
through an affine transformation with respect to an automatically chosen
reference, the 3D volume is reconstructed by co-registering 2D slices
elastically.Comment: SPIE Medical Imaging 2008 - submissio
Recommended from our members
Radiomics for Response and Outcome Assessment for Non-Small Cell Lung Cancer.
Routine follow-up visits and radiographic imaging are required for outcome evaluation and tumor recurrence monitoring. Yet more personalized surveillance is required in order to sufficiently address the nature of heterogeneity in nonsmall cell lung cancer and possible recurrences upon completion of treatment. Radiomics, an emerging noninvasive technology using medical imaging analysis and data mining methodology, has been adopted to the area of cancer diagnostics in recent years. Its potential application in response assessment for cancer treatment has also drawn considerable attention. Radiomics seeks to extract a large amount of valuable information from patients' medical images (both pretreatment and follow-up images) and quantitatively correlate image features with diagnostic and therapeutic outcomes. Radiomics relies on computers to identify and analyze vast amounts of quantitative image features that were previously overlooked, unmanageable, or failed to be identified (and recorded) by human eyes. The research area has been focusing on the predictive accuracy of pretreatment features for outcome and response and the early discovery of signs of tumor response, recurrence, distant metastasis, radiation-induced lung injury, death, and other outcomes, respectively. This review summarized the application of radiomics in response assessments in radiotherapy and chemotherapy for non-small cell lung cancer, including image acquisition/reconstruction, region of interest definition/segmentation, feature extraction, and feature selection and classification. The literature search for references of this article includes PubMed peer-reviewed publications over the last 10 years on the topics of radiomics, textural features, radiotherapy, chemotherapy, lung cancer, and response assessment. Summary tables of radiomics in response assessment and treatment outcome prediction in radiation oncology have been developed based on the comprehensive review of the literature
On the Experimental Evaluation of Vehicular Networks: Issues, Requirements and Methodology Applied to a Real Use Case
One of the most challenging fields in vehicular communications has been the
experimental assessment of protocols and novel technologies. Researchers
usually tend to simulate vehicular scenarios and/or partially validate new
contributions in the area by using constrained testbeds and carrying out minor
tests. In this line, the present work reviews the issues that pioneers in the
area of vehicular communications and, in general, in telematics, have to deal
with if they want to perform a good evaluation campaign by real testing. The
key needs for a good experimental evaluation is the use of proper software
tools for gathering testing data, post-processing and generating relevant
figures of merit and, finally, properly showing the most important results. For
this reason, a key contribution of this paper is the presentation of an
evaluation environment called AnaVANET, which covers the previous needs. By
using this tool and presenting a reference case of study, a generic testing
methodology is described and applied. This way, the usage of the IPv6 protocol
over a vehicle-to-vehicle routing protocol, and supporting IETF-based network
mobility, is tested at the same time the main features of the AnaVANET system
are presented. This work contributes in laying the foundations for a proper
experimental evaluation of vehicular networks and will be useful for many
researchers in the area.Comment: in EAI Endorsed Transactions on Industrial Networks and Intelligent
Systems, 201
Calibration and evaluation of optical systems for full-field strain measurement
The design and testing of a reference material for the calibration of optical systems for strain measurement is described, together with the design and testing of a standardized test material that allows the evaluation and assessment of fitness for purpose of the most sophisticated optical system for strain measurement. A classification system for the steps in the measurement process is also proposed and allows the development of a unified approach to diagnostic testing of components or sub-systems in an optical system for strain measurement based on any optical technique. The results described arise from a European study known as SPOTS whose objectives were to begin to fill the gap caused by a lack of standards
Accurate,robust and harmonized implementation of morpho-functional imaging in treatment planning for personalized radiotherapy
In this work we present a methodology able to use harmonized PET/CT imaging in dose painting by number (DPBN) approach by means of a robust and accurate treatment planning system. Image processing and treatment planning were performed by using a Matlab-based platform, called CARMEN, in which a full Monte Carlo simulation is included. Linear programming formulation was developed for a voxel-by-voxel robust optimization and a specific direct aperture optimization was designed for an efficient adaptive radiotherapy implementation. DPBN approach with our methodology was tested to reduce the uncertainties associated with both, the absolute value and the relative value of the information in the functional image. For the same H&N case, a single robust treatment was planned for dose prescription maps corresponding to standardized uptake value distributions from two different image reconstruction protocols: One to fulfill EARL accreditation for harmonization of [18F]FDG PET/CT image, and the other one to use the highest available spatial resolution. Also, a robust treatment was planned to fulfill dose prescription maps corresponding to both approaches, the dose painting by contour based on volumes and our voxel-by-voxel DPBN. Adaptive planning was also carried out to check the suitability of our proposal.
Different plans showed robustness to cover a range of scenarios for implementation of harmonizing strategies by using the highest available resolution. Also, robustness associated to discretization level of dose prescription according to the use of contours or numbers was achieved. All plans showed excellent quality index histogram and quality factors below 2%. Efficient solution for adaptive radiotherapy based directly on changes in functional image was obtained. We proved that by using voxel-by-voxel DPBN approach it is possible to overcome typical drawbacks linked to PET/CT images, providing to the clinical specialist confidence enough for routinely implementation of functional imaging for personalized radiotherapy.Junta de Andalucía (FISEVI, reference project CTS 2482)European Regional Development Fund (FEDER
Computerized Analysis of Magnetic Resonance Images to Study Cerebral Anatomy in Developing Neonates
The study of cerebral anatomy in developing neonates is of great importance for
the understanding of brain development during the early period of life. This
dissertation therefore focuses on three challenges in the modelling of cerebral
anatomy in neonates during brain development. The methods that have been
developed all use Magnetic Resonance Images (MRI) as source data.
To facilitate study of vascular development in the neonatal period, a set of image
analysis algorithms are developed to automatically extract and model cerebral
vessel trees. The whole process consists of cerebral vessel tracking from
automatically placed seed points, vessel tree generation, and vasculature
registration and matching. These algorithms have been tested on clinical Time-of-
Flight (TOF) MR angiographic datasets.
To facilitate study of the neonatal cortex a complete cerebral cortex segmentation
and reconstruction pipeline has been developed. Segmentation of the neonatal
cortex is not effectively done by existing algorithms designed for the adult brain
because the contrast between grey and white matter is reversed. This causes pixels
containing tissue mixtures to be incorrectly labelled by conventional methods. The
neonatal cortical segmentation method that has been developed is based on a novel
expectation-maximization (EM) method with explicit correction for mislabelled
partial volume voxels. Based on the resulting cortical segmentation, an implicit
surface evolution technique is adopted for the reconstruction of the cortex in
neonates. The performance of the method is investigated by performing a detailed
landmark study.
To facilitate study of cortical development, a cortical surface registration algorithm
for aligning the cortical surface is developed. The method first inflates extracted
cortical surfaces and then performs a non-rigid surface registration using free-form
deformations (FFDs) to remove residual alignment. Validation experiments using
data labelled by an expert observer demonstrate that the method can capture local
changes and follow the growth of specific sulcus
- …