532 research outputs found
Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance
<p>Abstract</p> <p>Background</p> <p>Phase contrast cardiovascular magnetic resonance (CMR) is able to measure all three directional components of the velocities of blood flow relative to the three spatial dimensions and the time course of the heart cycle. In this article, methods used for the acquisition, visualization, and quantification of such datasets are reviewed and illustrated.</p> <p>Methods</p> <p>Currently, the acquisition of 3D cine (4D) phase contrast velocity data, synchronized relative to both cardiac and respiratory movements takes about ten minutes or more, even when using parallel imaging and optimized pulse sequence design. The large resulting datasets need appropriate post processing for the visualization of multidirectional flow, for example as vector fields, pathlines or streamlines, or for retrospective volumetric quantification.</p> <p>Applications</p> <p>Multidirectional velocity acquisitions have provided 3D visualization of large scale flow features of the healthy heart and great vessels, and have shown altered patterns of flow in abnormal chambers and vessels. Clinically relevant examples include retrograde streams in atheromatous descending aortas as potential thrombo-embolic pathways in patients with cryptogenic stroke and marked variations of flow visualized in common aortic pathologies. Compared to standard clinical tools, 4D velocity mapping offers the potential for retrospective quantification of flow and other hemodynamic parameters.</p> <p>Conclusions</p> <p>Multidirectional, 3D cine velocity acquisitions are contributing to the understanding of normal and pathologically altered blood flow features. Although more rapid and user-friendly strategies for acquisition and analysis may be needed before 4D velocity acquisitions come to be adopted in routine clinical CMR, their capacity to measure multidirectional flows throughout a study volume has contributed novel insights into cardiovascular fluid dynamics in health and disease.</p
Autocalibrated cardiac tissue phase mapping with multiband imaging and k-t acceleration
PURPOSE: To develop an autocalibrated multiband (MB) CAIPIRINHA acquisition scheme with in-plane k-t acceleration enabling multislice three-directional tissue phase mapping in one breath-hold. METHODS: A k-t undersampling scheme was integrated into a time-resolved electrocardiographic-triggered autocalibrated MB gradient-echo sequence. The sequence was used to acquire data on 4 healthy volunteers with MB factors of two (MB2) and three (MB3), which were reconstructed using a joint reconstruction algorithm that tackles both k-t and MB acceleration. Forward simulations of the imaging process were used to tune the reconstruction model hyperparameters. Direct comparisons between MB and single-band tissue phase-mapping measurements were performed. RESULTS: Simulations showed that the velocities could be accurately reproduced with MB2 k-t (average ± twice the SD of the RMS error of 0.08 ± 0.22 cm/s and velocity peak reduction of 1.03% ± 6.47% compared with fully sampled velocities), whereas acceptable results were obtained with MB3 k-t (RMS error of 0.13 ± 0.58 cm/s and peak reduction of 2.21% ± 13.45%). When applied to tissue phase-mapping data, the proposed technique allowed three-directional velocity encoding to be simultaneously acquired at two/three slices in a single breath-hold of 18 heartbeats. No statistically significant differences were detected between MB2/MB3 k-t and single-band k-t motion traces averaged over the myocardium. Regional differences were found, however, when using the American Heart Association model for segmentation. CONCLUSION: An autocalibrated MB k-t acquisition / reconstruction framework is presented that allows three-directional velocity encoding of the myocardial velocities at multiple slices in one breath-hold
A clinical method for mapping and quantifying blood stasis in the left ventricle
In patients at risk of intraventrcular thrombosis, the benefits of chronic anticoagulation therapy need to be balanced with the pro-hemorrhagic effects of therapy. Blood stasis in the cardiac chambers is a recognized risk factor for intracardiac thrombosis and potential cardiogenic embolic events. In this work, we present a novel flow image-based method to assess the location and extent of intraventricular stasis regions inside the left ventricle (LV) by digital processing flow-velocity images obtained either by phase-contrast magnetic resonance (PCMR) or 2D color-Doppler velocimetry (echo-CDV). This approach is based on quantifying the distribution of the blood Residence Time (TR) from time-resolved blood velocity fields in the LV. We tested the new method in illustrative examples of normal hearts, patients with dilated cardiomyopathy and one patient before and after the implantation of a left ventricular assist device (LVAD). The method allowed us to assess in-vivo the location and extent of the stasis regions in the LV. Original metrics were developed to integrate flow properties into simple scalars suitable for a robust and personalized assessment of the risk of thrombosis. From a clinical perspective, this work introduces the new paradigm that quantitative flow dynamics can provide the basis to obtain subclinical markers of intraventricular thrombosis risk. The early prediction of LV blood stasis may result in decrease strokes by appropriate use of anticoagulant therapy for the purpose of primary and secondary prevention. It may also have a significant impact on LVAD device design and operation set-up
Recommended from our members
Coronary Occlusion Detection with 4D Optical Flow Based Strain Estimation on 4D Ultrasound
Real-time three-dimensional echocardiography (RT3DE) offers an efficient way to obtain complete 3D images of the heart over an entire cardiac cycle in just a few seconds. The complex 3D wall motion and temporal information contained in these 4D data sequences has the potential to enhance and supplement other imaging modalities for clinical diagnoses based on cardiac motion analysis. In our previous work, a 4D optical flow based method was developed to estimate dynamic cardiac metrics, including strains and displacements, from 4D ultrasound. In this study, in order to evaluate the ability of our method in detecting ischemic regions, coronary artery occlusion experiments at various locations were performed on five dogs. 4D ultrasound data acquired during these experiments were analyzed with our proposed method. Ischemic regions predicted by the outcome of strain measurements were compared to predictions from cardiac physiology with strong agreement. This is the first direct validation study of our image analysis method for biomechanical prediction and in vivo experimental outcome
Recommended from our members
2-D and 3-D high frame-rate Pulse Wave Imaging for the characterization of focal vascular disease
Cardiovascular diseases are major causes of morbidity and mortality in Western-style populations. Atherosclerosis and Abdominal Aortic Aneurysms (AAAs) are two prevalent vascular diseases that may progress without symptoms and contribute to acute cardiovascular events such as stroke and AAA rupture, which are consistently among the leading causes of death worldwide. The imaging methods used in the diagnosis of these diseases, have been reported to present several limitations. Given that both are associated with mechanical changes in the arterial wall, imaging of the arterial mechanical properties may improve early disease detection and patient care.
Pulse wave velocity (PWV) refers to the velocity at which arterial waves generated by ventricular ejection travel along the arterial tree. PWV is a surrogate marker of arterial stiffness linked to cardiovascular mortality. The foot-to-foot method that is typically used to calculate PWV suffers from errors of distance measurements and time-delay measurements. Additionally, a single PWV estimate is provided over a relatively long distance, thus inherently lacking the capability to provide regional arterial stiffness measurements. Pulse Wave Imaging (PWI) is a noninvasive, ultrasound-based technique for imaging the propagation of pulse waves along the wall of major arteries and providing a regional PWV value for the imaged artery.
The aim of this work was to enable PWI to provide more localized PWV and stiffness measurements within the imaged arterial segment and to further extend it into a 2-D and 3-D technique for the detection and monitoring of focal vascular disease at high temporal and spatial resolution. The improved modality was integrated with blood flow imaging modalities aiming to render PWI a comprehensive methodology for the study of arterial biomechanics in vivo.
Spatial information was increased with the introduction of piecewise PWI. This novel technique was used to measure PWV within small sub-regions of the imaged vessel in murine aneurysmal (n = 8) and atherosclerotic aortas (n = 11) in vivo. It provided PWV and stiffness maps while capturing the progressive arterial stiffening caused by atherosclerosis. PWI was further augmented with a sophisticated adaptive algorithm, enabling it to optimally partition the imaged artery into relatively homogeneous segments, automatically isolating arterial stiffness inhomogeneities. Adaptive PWI was validated in silicone phantoms consisting of segments of varying stiffness and then tested in murine aortas in vivo.
Subsequently, the conventional tradeoff between spatial and temporal resolution was addressed with a plane wave compounding implementation of PWI, allowing the acquisition of full field of view frames at over 2000 Hz. A GPU-accelerated PWI post-processing framework was developed for the processing of the big bulk of generated data. The parameters of coherent compounding were optimized in vivo. The optimized sequences were then used in the clinic to assess the mechanical properties of atherosclerotic carotids (n=10) and carotids of patients after endarterectomy (n=7), a procedure to remove the plaque and restore blood flow to the brain. In the case of atherosclerotic patients undergoing carotid endarterectomy, the results were compared against the histology of the excised plaques. Investigation of the mechanical properties of plaques was also conducted for the first time with a high-frequency transducer (18.5 MHz).
Additionally, 4-D PWI was introduced, utilizing high frame rate 3-D plane wave acquisitions with a 2-D matrix array transducer (16x16 elements, 2.5 MHz). A novel methodology for PWV estimation along the direction of pulse wave propagation was implemented and validated in silicone phantoms. 4-D PWI provided comprehensive views of the pulse wave propagation in a plaque phantom and the results were compared against conventional PWI. Finally, its feasibility was tested in the carotid arteries of healthy human subjects (n=6). PWVs derived in 3-D were within the physiological range and showed good agreement with the results of conventional PWI.
Finally, PWI was integrated with flow imaging modalities (Color and Vector Doppler). Thus, full field-of-view, high frame-rate, simultaneous and co-localized imaging of the arterial wall dynamics and color flow as well as 2-D vector flow was implemented. The feasibility of both techniques was tested in healthy subjects (n=6) in vivo. The relationship between the timings of the flow and wall velocities was investigated at multiple locations of the imaged artery. Vector flow velocities were found to be aligned with the vesselâs centerline during peak systole in the common carotid artery and interesting flow patterns were revealed in the case of the carotid bifurcation
Consequently, with the aforementioned improvements and the inclusion of 3-D imaging, PWI is expected to provide comprehensive information on the mechanical properties of pathological arteries, providing clinicians with a powerful tool for the early detection of vascular abnormalities undetectable on the B-mode, while also enabling the monitoring of fully developed vascular pathology and of the recovery of post-operated vessels
Accelerated CMR using zonal, parallel and prior knowledge driven imaging methods
Accelerated imaging is highly relevant for many CMR applications as competing constraints with respect to spatiotemporal resolution and tolerable scan times are frequently posed. Three approaches, all involving data undersampling to increase scan efficiencies, are discussed in this review. Zonal imaging can be considered a niche but nevertheless has found application in coronary imaging and CMR flow measurements. Current work on parallel-transmit systems is expected to revive the interest in zonal imaging techniques. The second and main approach to speeding up CMR sequences has been parallel imaging. A wide range of CMR applications has benefited from parallel imaging with reduction factors of two to three routinely applied for functional assessment, perfusion, viability and coronary imaging. Large coil arrays, as are becoming increasingly available, are expected to support reduction factors greater than three to four in particular in combination with 3D imaging protocols. Despite these prospects, theoretical work has indicated fundamental limits of coil encoding at clinically available magnetic field strengths. In that respect, alternative approaches exploiting prior knowledge about the object being imaged as such or jointly with parallel imaging have attracted considerable attention. Five to eight-fold scan accelerations in cine and dynamic CMR applications have been reported and image quality has been found to be favorable relative to using parallel imaging alone
- âŠ