18,216 research outputs found

    Region-enhanced passive radar imaging

    Get PDF
    The authors adapt and apply a recently-developed region-enhanced synthetic aperture radar (SAR) image reconstruction technique to the problem of passive radar imaging. One goal in passive radar imaging is to form images of aircraft using signals transmitted by commercial radio and television stations that are reflected from the objects of interest. This involves reconstructing an image from sparse samples of its Fourier transform. Owing to the sparse nature of the aperture, a conventional image formation approach based on direct Fourier transformation results in quite dramatic artefacts in the image, as compared with the case of active SAR imaging. The regionenhanced image formation method considered is based on an explicit mathematical model of the observation process; hence, information about the nature of the aperture is explicitly taken into account in image formation. Furthermore, this framework allows the incorporation of prior information or constraints about the scene being imaged, which makes it possible to compensate for the limitations of the sparse apertures involved in passive radar imaging. As a result, conventional imaging artefacts, such as sidelobes, can be alleviated. Experimental results using data based on electromagnetic simulations demonstrate that this is a promising strategy for passive radar imaging, exhibiting significant suppression of artefacts, preservation of imaged object features, and robustness to measurement noise

    Analysis and Optimization of Synthetic Aperture Ultrasound Imaging Using the Effective Aperture Approach

    Get PDF
    An effective aperture approach is used as a tool for analysis and parameter optimization of mostly known ultrasound imaging systems - phased array systems, compounding systems and synthetic aperture imaging systems. Both characteristics of an imaging system, the effective aperture function and the corresponding two-way radiation pattern, provide information about two of the most important parameters of images produced by an ultrasound system - lateral resolution and contrast. Therefore, in the design, optimization of the effective aperture function leads to optimal choice of such parameters of an imaging systems that influence on lateral resolution and contrast of images produced by this imaging system. It is shown that the effective aperture approach can be used for optimization of a sparse synthetic transmit aperture (STA) imaging system. A new two-stage algorithm is proposed for optimization of both the positions of the transmitted elements and the weights of the receive elements. The proposed system employs a 64-element array with only four active elements used during transmit. The numerical results show that Hamming apodization gives the best compromise between the contrast of images and the lateral resolution

    Application Of Antenna Synthesis And Digital Signal Processing Techniques For Active Millimeter-wave Imaging Systems

    Get PDF
    Millimeter-wave imaging has gathered attention in recent years for its ability to penetrate clothing, thin layers of soils, and certain construction materials. However, image quality remains a challenge that needs to be addressed. One way of improving image quality is by increasing the dimensions of the collecting aperture. A sparse array can be used to synthesize a larger aperture with a limited set of relatively small detectors. In this research we design, build, and test a test-bed having an active source at 94 GHz and an array of coherent detectors, mounted on arms that extend radially on a rotary table. Using this test bed a circular area with a maximum diameter of 900 mm can be scanned. The signal is down-converted using heterodyne receivers with digital in-phase and quadrature detection. Signal correlation is performed using the digitized data, which is stored for post-processing, electronic focusing, and image reconstruction. Near-field imaging using interferometric reconstructions is achieved using electronic focusing. Imaging tests show the ability of the system to generate imagery of concealed and unconcealed objects at distances between 400 and 700 mm. A study of the effects of redundant and nonredundant configurations on image quality for 4 common detector configurations is presented. In this document we show that an active sparse-aperture imaging system using digital correlators is a viable way to generate millimeter-wave images

    Sparse Active Rectangular Array with Few Closely Spaced Elements

    Full text link
    Sparse sensor arrays offer a cost effective alternative to uniform arrays. By utilizing the co-array, a sparse array can match the performance of a filled array, despite having significantly fewer sensors. However, even sparse arrays can have many closely spaced elements, which may deteriorate the array performance in the presence of mutual coupling. This paper proposes a novel sparse planar array configuration with few unit inter-element spacings. This Concentric Rectangular Array (CRA) is designed for active sensing tasks, such as microwave or ultra-sound imaging, in which the same elements are used for both transmission and reception. The properties of the CRA are compared to two well-known sparse geometries: the Boundary Array and the Minimum-Redundancy Array (MRA). Numerical searches reveal that the CRA is the MRA with the fewest unit element displacements for certain array dimensions.Comment: 4+1 pages, 5 figures, 1 tabl

    Cost-effective aperture arrays for SKA Phase 1: single or dual-band?

    Full text link
    An important design decision for the first phase of the Square Kilometre Array is whether the low frequency component (SKA1-low) should be implemented as a single or dual-band aperture array; that is, using one or two antenna element designs to observe the 70-450 MHz frequency band. This memo uses an elementary parametric analysis to make a quantitative, first-order cost comparison of representative implementations of a single and dual-band system, chosen for comparable performance characteristics. A direct comparison of the SKA1-low station costs reveals that those costs are similar, although the uncertainties are high. The cost impact on the broader telescope system varies: the deployment and site preparation costs are higher for the dual-band array, but the digital signal processing costs are higher for the single-band array. This parametric analysis also shows that a first stage of analogue tile beamforming, as opposed to only station-level, all-digital beamforming, has the potential to significantly reduce the cost of the SKA1-low stations. However, tile beamforming can limit flexibility and performance, principally in terms of reducing accessible field of view. We examine the cost impacts in the context of scientific performance, for which the spacing and intra-station layout of the antenna elements are important derived parameters. We discuss the implications of the many possible intra-station signal transport and processing architectures and consider areas where future work could improve the accuracy of SKA1-low costing.Comment: 64 pages, 23 figures, submitted to the SKA Memo serie

    Lensless wide-field fluorescent imaging on a chip using compressive decoding of sparse objects.

    Get PDF
    We demonstrate the use of a compressive sampling algorithm for on-chip fluorescent imaging of sparse objects over an ultra-large field-of-view (>8 cm(2)) without the need for any lenses or mechanical scanning. In this lensfree imaging technique, fluorescent samples placed on a chip are excited through a prism interface, where the pump light is filtered out by total internal reflection after exciting the entire sample volume. The emitted fluorescent light from the specimen is collected through an on-chip fiber-optic faceplate and is delivered to a wide field-of-view opto-electronic sensor array for lensless recording of fluorescent spots corresponding to the samples. A compressive sampling based optimization algorithm is then used to rapidly reconstruct the sparse distribution of fluorescent sources to achieve approximately 10 microm spatial resolution over the entire active region of the sensor-array, i.e., over an imaging field-of-view of >8 cm(2). Such a wide-field lensless fluorescent imaging platform could especially be significant for high-throughput imaging cytometry, rare cell analysis, as well as for micro-array research
    corecore