2,196 research outputs found

    Active sensor fault tolerant output feedback tracking control for wind turbine systems via T-S model

    Get PDF
    This paper presents a new approach to active sensor fault tolerant tracking control (FTTC) for offshore wind turbine (OWT) described via Takagi–Sugeno (T–S) multiple models. The FTTC strategy is designed in such way that aims to maintain nominal wind turbine controller without any change in both fault and fault-free cases. This is achieved by inserting T–S proportional state estimators augmented with proportional and integral feedback (PPI) fault estimators to be capable to estimate different generators and rotor speed sensors fault for compensation purposes. Due to the dependency of the FTTC strategy on the fault estimation the designed observer has the capability to estimate a wide range of time varying fault signals. Moreover, the robustness of the observer against the difference between the anemometer wind speed measurement and the immeasurable effective wind speed signal has been taken into account. The corrected measurements fed to a T–S fuzzy dynamic output feedback controller (TSDOFC) designed to track the desired trajectory. The stability proof with H∞ performance and D-stability constraints is formulated as a Linear Matrix Inequality (LMI) problem. The strategy is illustrated using a non-linear benchmark system model of a wind turbine offered within a competition led by the companies Mathworks and KK-Electronic

    Integrated fault estimation and fault-tolerant control for stochastic systems with Brownian motions

    Get PDF
    This paper presents an integrated robust fault estimation and fault‐tolerant control technique for stochastic systems subjected to Brownian parameter perturbations. The augmented system approach, unknown input observer method, and optimization technique are integrated to achieve robust simultaneous estimates of the system states and the means of faults concerned. Meanwhile, a robust fault‐tolerant control strategy is developed by using actuator and sensor signal compensation techniques. Stochastic linear time‐invariant systems, stochastic systems with Lipschitz nonlinear constraint, and stochastic systems with quadratic inner‐bounded nonlinear constraint are respectively investigated, and the corresponding fault‐tolerant control algorithms are addressed. Finally, the effectiveness of the proposed fault‐tolerant control techniques is demonstrated via the drivetrain system of a 4.8 MW benchmark wind turbine, a 3‐tank system, and a numerical nonlinear model

    Trade-offs on fault estimation via proportional multiple-integral and multiple-resonant observers for discrete-time systems

    Get PDF
    The authors develop a fault estimation strategy which is based on a novel proportional multiple-integral (PMI) and multiple-resonant observer. This observer is an extension of the well-known PMI observer and it is able to estimate from low to high-frequency fault signals. The proposed estimation strategy is applied to discrete-time systems which are affected by faults and stochastic noises. We present a multi-objective design strategy of the observer that fixes the trade-offs between practical engineering parameters regarding the noise attenuation and the ability to track each kind of fault dynamics considered by the augmented observer. They study the influence of the order of the observer on the steady-state and transient performance of the estimation of different types of faults. Finally, a numerical example is given to illustrate the effectiveness of the proposed observer, design and characterisation

    Distributed Fault Detection in Formation of Multi-Agent Systems with Attack Impact Analysis

    Get PDF
    Autonomous Underwater Vehicles (AUVs) are capable of performing a variety of deepwater marine applications as in multiple mobile robots and cooperative robot reconnaissance. Due to the environment that AUVs operate in, fault detection and isolation as well as the formation control of AUVs are more challenging than other Multi-Agent Systems (MASs). In this thesis, two main challenges are tackled. We first investigate the formation control and fault accommodation algorithms for AUVs in presence of abnormal events such as faults and communication attacks in any of the team members. These undesirable events can prevent the entire team to achieve a safe, reliable, and efficient performance while executing underwater mission tasks. For instance, AUVs may face unexpected actuator/sensor faults and the communication between AUVs can be compromised, and consequently make the entire multi-agent system vulnerable to cyber-attacks. Moreover, a possible deception attack on network system may have a negative impact on the environment and more importantly the national security. Furthermore, there are certain requirements for speed, position or depth of the AUV team. For this reason, we propose a distributed fault detection scheme that is able to detect and isolate faults in AUVs while maintaining their formation under security constraints. The effects of faults and communication attacks with a control theoretical perspective will be studied. Another contribution of this thesis is to study a state estimation problem for a linear dynamical system in presence of a Bias Injection Attack (BIA). For this purpose, a Kalman Filter (KF) is used, where we show that the impact of an attack can be analyzed as the solution of a quadratically constrained problem for which the exact solution can be found efficiently. We also introduce a lower bound for the attack impact in terms of the number of compromised actuators and a combination of sensors and actuators. The theoretical findings are accompanied by simulation results and numerical can study examples

    Restructurable Controls

    Get PDF
    Restructurable control system theory, robust reconfiguration for high reliability and survivability for advanced aircraft, restructurable controls problem definition and research, experimentation, system identification methods applied to aircraft, a self-repairing digital flight control system, and state-of-the-art theory application are addressed

    Review of selection criteria for sensor and actuator configurations suitable for internal combustion engines

    Get PDF
    This literature review considers the problem of finding a suitable configuration of sensors and actuators for the control of an internal combustion engine. It takes a look at the methods, algorithms, processes, metrics, applications, research groups and patents relevant for this topic. Several formal metric have been proposed, but practical use remains limited. Maximal information criteria are theoretically optimal for selecting sensors, but hard to apply to a system as complex and nonlinear as an engine. Thus, we reviewed methods applied to neighboring fields including nonlinear systems and non-minimal phase systems. Furthermore, the closed loop nature of control means that information is not the only consideration, and speed, stability and robustness have to be considered. The optimal use of sensor information also requires the use of models, observers, state estimators or virtual sensors, and practical acceptance of these remains limited. Simple control metrics such as conditioning number are popular, mostly because they need fewer assumptions than closed-loop metrics, which require a full plant, disturbance and goal model. Overall, no clear consensus can be found on the choice of metrics to define optimal control configurations, with physical measures, linear algebra metrics and modern control metrics all being used. Genetic algorithms and multi-criterial optimisation were identified as the most widely used methods for optimal sensor selection, although addressing the dimensionality and complexity of formulating the problem remains a challenge. This review does present a number of different successful approaches for specific applications domains, some of which may be applicable to diesel engines and other automotive applications. For a thorough treatment, non-linear dynamics and uncertainties need to be considered together, which requires sophisticated (non-Gaussian) stochastic models to establish the value of a control architecture

    Fault-tolerant load reduction control for large offshore wind turbines

    Get PDF
    Offshore wind turbines suffer from asymmetrical loading (blades, tower etc.), leading to enhanced structural fatigue. As well as asymmetrical loading different types of faults (pitch system faults etc.) can occur simultaneously, causing degradation of load mitigation performance and enhanced fatigue. Individual pitch control (IPC) provides an important method to achieve mitigation of rotor asymmetric loads, but this may be accompanied by a resulting enhancement of pitch movement leading to increased possibility of pitch system faults, which negative effects on IPC performance.This thesis focuses on combining the fault tolerant control (FTC) techniques with load reduction strategies by a more intelligent pitch control system (i.e. collective pitch control and IPC) for offshore wind turbines in a system level to reduce the operation & maintenance costs and improve the system reliability. The scenario of load mitigation is analogous to the FTC problem because the action of rotor/tower bending can be considered as a fault effect. The essential concept is to attempt to account for all the "fault effects" in the rotor and tower systems which can weaken the effect of bending moment reduction through the use of IPC.Motivated by the above, this thesis focuses on four aspects to fill the gap of the combination between FTC and IPC schemes. Firstly, a preview control system using model predictive control with future wind speed is proposed, which could be a possible alternative to using LiDAR technology when using preview control for load reduction. Secondly, a multivariable IPC controller for both blade and tower load mitigation considering the inherent couplings is investigated. Thirdly, appropriate control-based fault monitoring strategies including fault detection and fault estimation FE-based FTC scheme are proposed for several different pitch actuator/sensor faults. Furthermore, the combined analysis of an FE-based FTC strategy with the IPC system at a system level is provided and the robustness of the proposed strategy is verified

    Fault Detection and Isolation of Wind Turbines using Immune System Inspired Algorithms

    Get PDF
    Recently, the research focus on renewable sources of energy has been growing intensively. This is mainly due to potential depletion of fossil fuels and its associated environmental concerns, such as pollution and greenhouse gas emissions. Wind energy is one of the fastest growing sources of renewable energy, and policy makers in both developing and developed countries have built their vision on future energy supply based on and by emphasizing the wind power. The increase in the number of wind turbines, as well as their size, have led to undeniable care and attention to health and condition monitoring as well as fault diagnosis of wind turbine systems and their components. In this thesis, two main immune inspired algorithms are used to perform Fault Detection and Isolation (FDI) of a Wind Turbine (WT), namely the Negative Selection Algorithm (NSA) as well as the Dendritic Cell Algorithm (DCA). First, an NSA-based fault diagnosis methodology is proposed in which a hierarchical bank of NSAs is used to detect and isolate both individual as well as simultaneously occurring faults common to the wind turbines. A smoothing moving window filter is then utilized to further improve the reliability and performance of the proposed FDI scheme. Moreover, the performance of the proposed scheme is compared with the state-of-the-art data-driven technique, namely Support Vector Machine (SVM) to demonstrate and illustrate the superiority and advantages of the proposed NSA-based FDI scheme. Finally, a nonparametric statistical comparison test is implemented to evaluate the proposed methodology with that of the SVM under various fault severities. In the second part, another immune inspired methodology, namely the Dendritic Cell Algorithm (DCA) is used to perform online sensor fault FDI. A noise filter is also designed to attenuate the measurement noise, resulting in better FDI results. The proposed DCA-based FDI scheme is then compared with the previously developed NSA-based FDI scheme, and a nonparametric statistical comparison test is also performed. Both of the proposed immune inspired frameworks are applied to a well-known wind turbine benchmark model in order to validate the effectiveness of the proposed methodologies
    corecore