238 research outputs found
An Information-Centric Communication Infrastructure for Real-Time State Estimation of Active Distribution Networks
© 2010-2012 IEEE.The evolution toward emerging active distribution networks (ADNs) can be realized via a real-time state estimation (RTSE) application facilitated by the use of phasor measurement units (PMUs). A critical challenge in deploying PMU-based RTSE applications at large scale is the lack of a scalable and flexible communication infrastructure for the timely (i.e., sub-second) delivery of the high volume of synchronized and continuous synchrophasor measurements. We address this challenge by introducing a communication platform called C-DAX based on the information-centric networking (ICN) concept. With a topic-based publish-subscribe engine that decouples data producers and consumers in time and space, C-DAX enables efficient synchrophasor measurement delivery, as well as flexible and scalable (re)configuration of PMU data communication for seamless full observability of power conditions in complex and dynamic scenarios. Based on the derived set of requirements for supporting PMU-based RTSE in ADNs, we design the ICN-based C-DAX communication platform, together with a joint optimized physical network resource provisioning strategy, in order to enable the agile PMU data communications in near real-time. In this paper, C-DAX is validated via a field trial implementation deployed over a sample feeder in a real-distribution network; it is also evaluated through simulation-based experiments using a large set of real medium voltage grid topologies currently operating live in The Netherlands. This is the first work that applies emerging communication paradigms, such as ICN, to smart grids while maintaining the required hard real-time data delivery as demonstrated through field trials at national scale. As such, it aims to become a blueprint for the application of ICN-based general purpose communication platforms to ADNs
Cost-efficient Low Latency Communication Infrastructure for Synchrophasor Applications in Smart Grids
With the introduction of distributed renewable energy resources and new loads, such as electric vehicles, the power grid is evolving to become a highly dynamic system, that necessitates continuous and fine-grained observability of its operating conditions. In the context of the medium voltage (MV) grid, this has motivated the deployment of Phasor Measurement Units (PMUs), that offer high precision synchronized grid monitoring, enabling mission-critical applications such as fault detection/location. However, PMU-based applications present stringent delay requirements, raising a significant challenge to the communication infrastructure. In contrast to the high voltage domain, there is no clear vision for the communication and network topologies for the MV grid; a full fledged optical fiber-based communication infrastructure is a costly approach due to the density of PMUs required. In this work, we focus on the support of low-latency PMU-based applications in the MV domain, identifying and addressing the trade-off between communication infrastructure deployment costs and the corresponding performance. We study a large set of real MV grid topologies to get an in-depth understanding of the various key latency factors. Building on the gained insights, we propose three algorithms for the careful placement of high capacity links, targeting a balance between deployment costs and achieved latencies. Extensive simulations demonstrate that the proposed algorithms result in low-latency network topologies while reducing deployment costs by up to 80% in comparison to a ubiquitous deployment of costly high capacity links
Design and Experimental Validation of an LTE-based Synchrophasor Network in a Medium Voltage Distribution Grid
We present and experimentally validate in a real-scale medium voltage (MV) grid a synchrophasor network that exploits the availability of a public 4G LTE communication infrastructure. An 18 buses, 10\,kV feeder located in Huissen, The Netherlands, has been equipped with 10 Phasor Measurement Units (PMUs) connected to the MV grid by means of dedicated voltage and current sensors. The PMUs stream synchrophasor data through a public 4G LTE network via an information-centric networking-based middleware, named C-DAX. The measurements are received and time-aligned at a phasor data concentrator and fed to a real-time state estimation application. The paper presents the various field-trial components and validates the feasibility of exploiting the 4G LTE technology for PMU-based applications. Specifically we assess the performance of the adopted wireless telecommunication infrastructure with and without the C-DAX middleware, as well as the accuracy of the real-time state estimation process
Recommended from our members
Diagnostic Applications for Micro-Synchrophasor Measurements
This report articulates and justifies the preliminary selection of diagnostic applications for data from micro-synchrophasors (µPMUs) in electric power distribution systems that will be further studied and developed within the scope of the three-year ARPA-e award titled Micro-synchrophasors for Distribution Systems
Recommended from our members
Novel performance evaluation of information and communication technologies to enable wide area monitoring systems for enhanced transmission network operation
This thesis was submitted for the award of Doctor of Philosophy and was awarded by Brunel University London.The penetration of renewable energy sources has increased significantly in recent years due to the ongoing depletion of conventional resources and the transition to a low carbon energy system. Renewable energy sources such as wind energy are highly intermittent and unpredictable in nature, which makes the operation of the power grid more dynamic and therefore more complex. In order to operate the power system reliably under such conditions, Phasor Measurement Units (PMUs) through the use of satellite technology can offer a state-of-the-art Wide Area Monitoring System (WAMS) for improving power system monitoring, control and protection. They can improve the operation by providing highly precise and synchronised measurements near to real-time with higher frequency and accuracy. In order to achieve such objectives, a high-speed and reliable communications infrastructure is required to transfer time-critical PMU data from remote locations to the control centre. The signals measured by PMUs are transmitted across Local and Wide Area Networks, where they may encounter excessive delays. Signal delays can have a disruptive effect and make applications at best inefficient and at worse ineffective.
The main research contribution of this thesis is the performance evaluation of communication infrastructures for WAMS. The evaluation begins from inside substations and continues over wide areas from substations to control centre. Through laboratory-based investigations and simulations, the performance of communications infrastructure in a typical power system substation has been analysed. In addition, the performance evaluation of WAMS communications infrastructure has been presented. In the modelling and analysis, an existing WAMS as installed on the GB transmission system has been considered. The actual PMU packets as received at the Phasor Data Concentrator (PDC) were captured for latency analysis. A novel algorithmic procedure has been developed and implemented to automate the large-scale latency calculations. Furthermore, the internal delays of PMUs have been investigated, determined and analysed. Subsequently, the WAMS has been simulated and detailed comparisons have been performed between the simulated model results and WAMS performance data captured from the actual WAMS. The validated WAMS model has been used for analysing possible future developments as well as to test newly proposed mechanisms, protocols, etc. in order to improve the communications infrastructure performance
Security Analysis of Phasor Measurement Units in Smart Grid Communication Infrastructures
Phasor Measurement Units (PMUs), or synchrophasors, are rapidly being deployed in the smart grid with the goal of measuring phasor quantities concurrently from wide area distribution substations. By utilizing GPS receivers, PMUs can take a wide area snapshot of power systems. Thus, the possibility of blackouts in the smart grid, the next generation power grid, will be reduced. As the main enabler of Wide Area Measurement Systems (WAMS), PMUs transmit measured values to Phasor Data Concentrators (PDCs) by the synchrophasor standard IEEE C37.118. IEC 61850 and IEC 62351 are the communication protocols for the substation automation system and the security standard for the communication protocol of IEC 61850, respectively. According to the aforementioned communication and security protocols, as well as the implementation constraints of different platforms, HMAC-SHA1 was suggested by the TC 57 WG group in October 2009. The hash-based Message Authentication Code (MAC) is an algorithm for verifying both message integrity and authentication by using an iterative hash function and a supplied secret key. There are a variety of security attacks on the PMU communications infrastructure. Timing Side Channel Attack (SCA) is one of these possible attacks. In this thesis, timing side channel vulnerability against execution time of the HMAC-SHA1 authentication algorithm is studied. Both linear and negative binomial regression are used to model some security features of the stored key, e.g., its length and Hamming weight. The goal is to reveal secret-related information based on leakage models. The results would mitigate the cryptanalysis process of an attacker.
Adviser: Yi Qia
Vulnerability Assessment and Privacy-preserving Computations in Smart Grid
Modern advances in sensor, computing, and communication technologies enable various smart grid applications which highlight the vulnerability that requires novel approaches to the field of cybersecurity. While substantial numbers of technologies have been adopted to protect cyber attacks in smart grid, there lacks a comprehensive review of the implementations, impacts, and solutions of cyber attacks specific to the smart grid.In this dissertation, we are motivated to evaluate the security requirements for the smart grid which include three main properties: confidentiality, integrity, and availability. First, we review the cyber-physical security of the synchrophasor network, which highlights all three aspects of security issues. Taking the synchrophasor network as an example, we give an overview of how to attack a smart grid network. We test three types of attacks and show the impact of each attack consisting of denial-of-service attack, sniffing attack, and false data injection attack.Next, we discuss how to protect against each attack. For protecting availability, we examine possible defense strategies for the associated vulnerabilities.For protecting data integrity, a small-scale prototype of secure synchrophasor network is presented with different cryptosystems. Besides, a deep learning based time-series anomaly detector is proposed to detect injected measurement. Our approach observes both data measurements and network traffic features to jointly learn system states and can detect attacks when state vector estimator fails.For protecting data confidentiality, we propose privacy-preserving algorithms for two important smart grid applications. 1) A distributed privacy-preserving quadratic optimization algorithm to solve Security Constrained Optimal Power Flow (SCOPF) problem. The SCOPF problem is decomposed into small subproblems using the Alternating Direction Method of Multipliers (ADMM) and gradient projection algorithms. 2) We use Paillier cryptosystem to secure the computation of the power system dynamic simulation. The IEEE 3-Machine 9-Bus System is used to implement and demonstrate the proposed scheme. The security and performance analysis of our implementations demonstrate that our algorithms can prevent chosen-ciphertext attacks at a reasonable cost
- …