4,914 research outputs found

    A direct-sequence spread-spectrum communication system for integrated sensor microsystems

    Get PDF
    Some of the most important challenges in health-care technologies have been identified to be development of noninvasive systems and miniaturization. In developing the core technologies, progress is required in pushing the limits of miniaturization, minimizing the costs and power consumption of microsystems components, developing mobile/wireless communication infrastructures and computing technologies that are reliable. The implementation of such miniaturized systems has become feasible by the advent of system-on-chip technology, which enables us to integrate most of the components of a system on to a single chip. One of the most important tasks in such a system is to convey information reliably on a multiple-access-based environment. When considering the design of telecommunication system for such a network, the receiver is the key performance critical block. The paper describes the application environment, the choice of the communication protocol, the implementation of the transmitter and receiver circuitry, and research work carried out on studying the impact of input data characteristics and internal data path complexity on area and power performance of the receiver. We provide results using a test data recorded from a pH sensor. The results demonstrate satisfying functionality, area, and power constraints even when a degree of programmability is incorporated in the system

    Advanced photonic and electronic systems - WILGA 2017

    Get PDF
    WILGA annual symposium on advanced photonic and electronic systems has been organized by young scientist for young scientists since two decades. It traditionally gathers more than 350 young researchers and their tutors. Ph.D students and graduates present their recent achievements during well attended oral sessions. Wilga is a very good digest of Ph.D. works carried out at technical universities in electronics and photonics, as well as information sciences throughout Poland and some neighboring countries. Publishing patronage over Wilga keep Elektronika technical journal by SEP, IJET by PAN and Proceedings of SPIE. The latter world editorial series publishes annually more than 200 papers from Wilga. Wilga 2017 was the XL edition of this meeting. The following topical tracks were distinguished: photonics, electronics, information technologies and system research. The article is a digest of some chosen works presented during Wilga 2017 symposium. WILGA 2017 works were published in Proc. SPIE vol.10445

    The Smartphone Brain Scanner: A Portable Real-Time Neuroimaging System

    Get PDF
    Combining low cost wireless EEG sensors with smartphones offers novel opportunities for mobile brain imaging in an everyday context. We present a framework for building multi-platform, portable EEG applications with real-time 3D source reconstruction. The system - Smartphone Brain Scanner - combines an off-the-shelf neuroheadset or EEG cap with a smartphone or tablet, and as such represents the first fully mobile system for real-time 3D EEG imaging. We discuss the benefits and challenges of a fully portable system, including technical limitations as well as real-time reconstruction of 3D images of brain activity. We present examples of the brain activity captured in a simple experiment involving imagined finger tapping, showing that the acquired signal in a relevant brain region is similar to that obtained with standard EEG lab equipment. Although the quality of the signal in a mobile solution using a off-the-shelf consumer neuroheadset is lower compared to that obtained using high density standard EEG equipment, we propose that mobile application development may offset the disadvantages and provide completely new opportunities for neuroimaging in natural settings

    Magnetoencephalography

    Get PDF
    This is a practical book on MEG that covers a wide range of topics. The book begins with a series of reviews on the use of MEG for clinical applications, the study of cognitive functions in various diseases, and one chapter focusing specifically on studies of memory with MEG. There are sections with chapters that describe source localization issues, the use of beamformers and dipole source methods, as well as phase-based analyses, and a step-by-step guide to using dipoles for epilepsy spike analyses. The book ends with a section describing new innovations in MEG systems, namely an on-line real-time MEG data acquisition system, novel applications for MEG research, and a proposal for a helium re-circulation system. With such breadth of topics, there will be a chapter that is of interest to every MEG researcher or clinician

    Apollo experience report: Electronic systems test program accomplishments and results

    Get PDF
    A chronological record is presented of the Electronic Systems Test Program from its conception in May 1963 to December 1969. The original concept of the program, which was primarily a spacecraft/Manned Space Flight Network communications system compatibility and performance evaluation, is described. The evolution of these concepts to include various levels of test detail, as well as systems level design verification testing, is discussed. Actual implementation of these concepts is presented, and the facility to support the program is described. Test results are given, and significant contributions to the lunar landing mission are underlined. Plans for modifying the facility and the concepts, based on Apollo experience, are proposed

    Digital Signal Processing Reveals Circadian Baseline Oscillation in Majority of Mammalian Genes

    Get PDF
    In mammals, circadian periodicity has been described for gene expression in the hypothalamus and multiple peripheral tissues. It is accepted that 10%–15% of all genes oscillate in a daily rhythm, regulated by an intrinsic molecular clock. Statistical analyses of periodicity are limited by the small size of datasets and high levels of stochastic noise. Here, we propose a new approach applying digital signal processing algorithms separately to each group of genes oscillating in the same phase. Combined with the statistical tests for periodicity, this method identifies circadian baseline oscillation in almost 100% of all expressed genes. Consequently, circadian oscillation in gene expression should be evaluated in any study related to biological pathways. Changes in gene expression caused by mutations or regulation of environmental factors (such as photic stimuli or feeding) should be considered in the context of changes in the amplitude and phase of genetic oscillations

    Speech-brain synchronization: a possible cause for developmental dyslexia

    Get PDF
    152 p.Dyslexia is a neurological learning disability characterized by the difficulty in an individual¿s ability to read despite adequate intelligence and normal opportunities. The majority of dyslexic readers present phonological difficulties. The phonological difficulty most often associated with dyslexia is a deficit in phonological awareness, that is, the ability to hear and manipulate the sound structure of language. Some appealing theories of dyslexia attribute a causal role to auditory atypical oscillatory neural activity, suggesting it generates some of the phonological problems in dyslexia. These theories propose that auditory cortical oscillations of dyslexic individuals entrain less accurately to the spectral properties of auditory stimuli at distinct frequency bands (delta, theta and gamma) that are important for speech processing. Nevertheless, there are diverging hypotheses concerning the specific bands that would be disrupted in dyslexia, and which are the consequences of such difficulties on speech processing. The goal of the present PhD thesis was to portray the neural oscillatory basis underlying phonological difficulties in developmental dyslexia. We evaluated whether phonological deficits in developmental dyslexia are associated with impaired auditory entrainment to a specific frequency band. In that aim, we measured auditory neural synchronization to linguistic and non-linguistic auditory signals at different frequencies corresponding to key phonological units of speech (prosodic, syllabic and phonemic information). We found that dyslexic readers presented atypical neural entrainment to delta, theta and gamma frequency bands. Importantly, we showed that atypical entrainment to theta and gamma modulations in dyslexia could compromise perceptual computations during speech processing, while reduced delta entrainment in dyslexia could affect perceptual and attentional operations during speech processing. In addition, we characterized the links between the anatomy of the auditory cortex and its oscillatory responses, taking into account previous studies which have observed structural alterations in dyslexia. We observed that the cortical pruning in auditory regions was linked to a stronger sensitivity to gamma oscillation in skilled readers, but to stronger theta band sensitivity in dyslexic readers. Thus, we concluded that the left auditory regions might be specialized for processing phonological information at different time scales (phoneme vs. syllable) in skilled and dyslexic readers. Lastly, by assessing both children and adults on similar tasks, we provided the first evaluation of developmental modulations of typical and atypical auditory sampling (and their structural underpinnings). We found that atypical neural entrainment to delta, theta and gamma are present in dyslexia throughout the lifespan and is not modulated by reading experience

    Modulation Scheme Analysis for Low-Power Leadless Pacemaker Synchronization Based on Conductive Intracardiac Communication

    Get PDF
    Conductive intracardiac communication (CIC) has been demonstrated as a promising concept for the synchronization of multi-chamber leadless cardiac pacemakers (LLPMs). To meet the 2–5 μ W power budget of a LLPM, highly specialized CIC-transceivers, which make optimal use of the cardiac communication channel, need to be developed. However, a detailed investigation of the optimal communication parameters for CIC-based LLPM synchronization is missing so far. This work analyzes the intracardiac communication performance of two low-power modulation techniques, namely On-Off-Keying (OOK) and Manchester-encoded baseband transmission (BB-MAN), as a function of the transmitted bit-energy. The bit error rate (BER) of a prototype dual-chamber LLPM was determined both in simulation and in-vitro experiments on porcine hearts. A BER of 1e − 4 was achieved with a median bit-energy in the range of 3-16 pJ (interquartile range: 4-15 pJ) for data rates from 75-500 kbps and a receiver input noise density of 7 nV/ √Hz . Both modulation schemes showed comparable performance, with BB-MAN having a slight bit-energy advantage (1-2 dB at 150-500 kbps) under equalized transceiver characteristics. This study demonstrates that reliable CIC-based LLPM synchronization is feasible at transmitted power levels < 10 nW under realistic channel conditions and receiver noise performance. Therefore, modulation techniques such, as BB-MAN or OOK, are preferable over recently proposed alternatives, such as pulse position modulation or conductive impulse signaling, since they can be realized with fewer hardware resources and smaller bandwidth requirements. Ultimately, a baseband communication approach might be favored over OOK, due to the more efficient cardiac signal transmission and reduced transceiver complexity
    corecore