91 research outputs found

    Medical robotics:haptic feedback for biorobotics

    Get PDF

    Surgical Applications of Compliant Mechanisms:A Review

    Get PDF
    Current surgical devices are mostly rigid and are made of stiff materials, even though their predominant use is on soft and wet tissues. With the emergence of compliant mechanisms (CMs), surgical tools can be designed to be flexible and made using soft materials. CMs offer many advantages such as monolithic fabrication, high precision, no wear, no friction, and no need for lubrication. It is therefore beneficial to consolidate the developments in this field and point to challenges ahead. With this objective, in this article, we review the application of CMs to surgical interventions. The scope of the review covers five aspects that are important in the development of surgical devices: (i) conceptual design and synthesis, (ii) analysis, (iii) materials, (iv) maim facturing, and (v) actuation. Furthermore, the surgical applications of CMs are assessed by classification into five major groups, namely, (i) grasping and cutting, (ii) reachability and steerability, (iii) transmission, (iv) sensing, and (v) implants and deployable devices. The scope and prospects of surgical devices using CMs are also discussed

    An anthropomorphic design for a minimally invasive surgical system based on a survey of surgical technologies, techniques and training

    Get PDF
    © 2013 John Wiley & Sons, Ltd. Background: Over the past century, abdominal surgery has seen a rapid transition from open procedures to less invasive methods, such as robot-assisted minimally invasive surgery (MIS). This study aimed to investigate and discuss the needs of MIS in terms of instrumentation and to inform the design of a novel instrument. Methods: A survey was conducted among surgeons regarding their opinions on surgical training, surgical systems, how satisfied they were with them and how easy they were to use. A concept for MIS robotic instrumentation was then developed and a series of focus groups with surgeons were run to discuss it. The initial prototype of the robotic instruments, herein demonstrated, comprises modular rigid links with soft joints actuated by shape memory alloy helix actuators; these instruments are controlled using a sensory hand exoskeleton. Results: The results of the survey, as well as those of the focus groups, are presented here. A first prototype of the system was built and initial laboratory tests have been conducted in order to evaluate this approach. Conclusions: The analysed data from both the survey and the focus groups justify the chosen concept of an anthropomorphic MIS robotic system which imitates the natural motion of the hands

    Prevalence of haptic feedback in robot-mediated surgery : a systematic review of literature

    Get PDF
    © 2017 Springer-Verlag. This is a post-peer-review, pre-copyedit version of an article published in Journal of Robotic Surgery. The final authenticated version is available online at: https://doi.org/10.1007/s11701-017-0763-4With the successful uptake and inclusion of robotic systems in minimally invasive surgery and with the increasing application of robotic surgery (RS) in numerous surgical specialities worldwide, there is now a need to develop and enhance the technology further. One such improvement is the implementation and amalgamation of haptic feedback technology into RS which will permit the operating surgeon on the console to receive haptic information on the type of tissue being operated on. The main advantage of using this is to allow the operating surgeon to feel and control the amount of force applied to different tissues during surgery thus minimising the risk of tissue damage due to both the direct and indirect effects of excessive tissue force or tension being applied during RS. We performed a two-rater systematic review to identify the latest developments and potential avenues of improving technology in the application and implementation of haptic feedback technology to the operating surgeon on the console during RS. This review provides a summary of technological enhancements in RS, considering different stages of work, from proof of concept to cadaver tissue testing, surgery in animals, and finally real implementation in surgical practice. We identify that at the time of this review, while there is a unanimous agreement regarding need for haptic and tactile feedback, there are no solutions or products available that address this need. There is a scope and need for new developments in haptic augmentation for robot-mediated surgery with the aim of improving patient care and robotic surgical technology further.Peer reviewe

    Electropermanent magnetic anchoring for surgery and endoscopy

    Get PDF
    The use of magnets for anchoring of instrumentation in minimally invasive surgery and endoscopy has become of increased interest in recent years. Permanent magnets have significant advantages over electromagnets for these applications; larger anchoring and retraction force for comparable size and volume without the need for any external power supply. However, permanent magnets represent a potential hazard in the operating field where inadvertent attraction to surgical instrumentation is often undesirable. The current work proposes an interesting hybrid approach which marries the high forces of permanent magnets with the control of electromagnetic technology including the ability to turn the magnet OFF when necessary. This is achieved through the use of an electropermanent magnet, which is designed for surgical retraction across the abdominal and gastric walls. Our electropermanent magnet, which is hand-held and does not require continuous power, is designed with a center lumen which may be used for trocar or needle insertion. The device in this application has been demonstrated successfully in the porcine model where coupling between an intraluminal ring magnet and our electropermanent magnet facilitated guided insertion of an 18 Fr Tuohy needle for guidewire placement. Subsequent investigations have demonstrated the ability to control the coupling distance of the system alleviating shortcomings with current methods of magnetic coupling due to variation in transabdominal wall thicknesses. With further refinement, the magnet may find application in the anchoring of endoscopic and surgical instrumentation for minimally invasive interventions in the gastrointestinal tract

    Monolithic self-supportive bi-directional bending pneumatic bellows catheter

    Get PDF
    The minimally invasive surgery has proven to be advantageous over conventional open surgery in terms of reduction in recovery time, patient trauma, and overall cost of treatment. To perform a minimally invasive procedure, preliminary insertion of a flexible tube or catheter is crucial without sacrificing its ability to manoeuvre. Nevertheless, despite the vast amount of research reported on catheters, the ability to implement active catheters in the minimally invasive application is still limited. To date, active catheters are made of rigid structures constricted to the use of wires or on-board power supplies for actuation, which increases the risk of damaging the internal organs and tissues. To address this issue, an active catheter made of soft, flexible and biocompatible structure, driven via nonelectric stimulus is of utmost importance. This thesis presents the development of a novel monolithic self-supportive bi-directional bending pneumatic bellows catheter using a sacrificial molding technique. As a proof of concept, in order to understand the effects of structural parameters on the bending performance of a bellows-structured actuator, a single channel circular bellows pneumatic actuator was designed. The finite element analysis was performed in order to analyze the unidirectional bending performance, while the most optimal model was fabricated for experimental validation. Moreover, to attain biocompatibility and bidirectional bending, the novel monolithic polydimethylsiloxane (PDMS)-based dual-channel square bellows pneumatic actuator was proposed. The actuator was designed with an overall cross-sectional area of 5 x 5 mm2, while the input sequence and the number of bellows were characterized to identify their effects on the bending performance. A novel sacrificial molding technique was adopted for developing the monolithic-structured actuator, which enabled simple fabrication for complex designs. The experimental validation revealed that the actuator model with a size of5 x 5 x 68.4 mm3 i.e. having the highest number of bellows, attained optimal bi-directional bending with maximum angles of -65° and 75°, and force of 0.166 and 0.221 N under left and right channel actuation, respectively, at 100 kPa pressure. The bending performance characterization and thermal insusceptibility achieved by the developed pneumatic catheter presents a promising implementation of flexibility and thermal stability for various biomedical applications, such as dialysis and cardiac catheterization

    Soft Robot-Assisted Minimally Invasive Surgery and Interventions: Advances and Outlook

    Get PDF
    Since the emergence of soft robotics around two decades ago, research interest in the field has escalated at a pace. It is fuelled by the industry's appreciation of the wide range of soft materials available that can be used to create highly dexterous robots with adaptability characteristics far beyond that which can be achieved with rigid component devices. The ability, inherent in soft robots, to compliantly adapt to the environment, has significantly sparked interest from the surgical robotics community. This article provides an in-depth overview of recent progress and outlines the remaining challenges in the development of soft robotics for minimally invasive surgery

    Shape Memory Alloy Actuators and Sensors for Applications in Minimally Invasive Interventions

    Get PDF
    Reduced access size in minimally invasive surgery and therapy (MIST) poses several restriction on the design of the dexterous robotic instruments. The instruments should be developed that are slender enough to pass through the small sized incisions and able to effectively operate in a compact workspace. Most existing robotic instruments are operated by big actuators, located outside the patient’s body, that transfer forces to the end effector via cables or magnetically controlled actuation mechanism. These instruments are certainly far from optimal in terms of their cost and the space they require in operating room. The lack of adequate sensing technologies make it very challenging to measure bending of the flexible instruments, and to measure tool-tissue contact forces of the both flexible and rigid instruments during MIST. Therefore, it requires the development of the cost effective miniature actuators and strain/force sensors. Having several unique features such as bio-compatibility, low cost, light weight, large actuation forces and electrical resistivity variations, the shape memory alloys (SMAs) show promising applications both as the actuators and strain sensors in MIST. However, highly nonlinear hysteretic behavior of the SMAs hinders their use as actuators. To overcome this problem, an adaptive artificial neural network (ANN) based Preisach model and a model predictive controller have been developed in this thesis to precisely control the output of the SMA actuators. A novel ultra thin strain sensor is also designed using a superelastic SMA wire, which can be used to measure strain and forces for many surgical and intervention instruments. A da Vinci surgical instrument is sensorized with these sensors in order to validate their force sensing capability
    • …
    corecore