4,176 research outputs found

    Optimal sensor placement for classifier-based leak localization in drinking water networks

    Get PDF
    © 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.This paper presents a sensor placement method for classifier-based leak localization in Water Distribution Networks. The proposed approach consists in applying a Genetic Algorithm to decide the sensors to be used by a classifier (based on the k-Nearest Neighbor approach). The sensors are placed in an optimal way maximizing the accuracy of the leak localization. The results are illustrated by means of the application to the Hanoi District Metered Area and they are compared to the ones obtained by the Exhaustive Search Algorithm. A comparison with the results of a previous optimal sensor placement method is provided as well.Postprint (author's final draft

    Selection of sensors by a new methodology coupling a classification technique and entropy criteria

    Get PDF
    Complex industrial processes invest a lot of money in sensors and automation devices to monitor and supervise the process in order to guarantee the production quality and the plant and operators safety. Fault detection is one of the multiple tasks of process monitoring and it critically depends on the sensors that measure the significant process variables. Nevertheless, most of the works on fault detection and diagnosis found in literature emphasis more on developing procedures to perform diagnosis given a set of sensors, and less on determining the actual location of sensors for efficient identification of faults. A methodology based on learning and classification techniques and on the information quantity measured by the Entropy concept, is proposed in order to address the problem of sensor location for fault identification. The proposed methodology has been applied to a continuous intensified reactor, the "Open Plate Reactor (OPR)", developed by Alfa Laval and studied at the Laboratory of Chemical Engineering of Toulouse. The different steps of the methodology are explained through its application to the carrying out of an exothermic reaction

    Leak localization in water distribution networks using a mixed model-based/data-driven approach

    Get PDF
    “The final publication is available at Springer via http://dx.doi.org/10.1016/j.conengprac.2016.07.006”This paper proposes a new method for leak localization in water distribution networks (WDNs). In a first stage, residuals are obtained by comparing pressure measurements with the estimations provided by a WDN model. In a second stage, a classifier is applied to the residuals with the aim of determining the leak location. The classifier is trained with data generated by simulation of the WDN under different leak scenarios and uncertainty conditions. The proposed method is tested both by using synthetic and experimental data with real WDNs of different sizes. The comparison with the current existing approaches shows a performance improvement.Peer ReviewedPostprint (author's final draft

    Modelling uncertainty for leak localization in Water Networks

    Get PDF
    The performance and success of model-based leak localization methods applied to water distribution networks (WDN) highly depends on the uncertainty of the system considered. This work proposes an original method of modeling the effect of uncertainties in these networks. The proposed method is based on the collection of real data in the water network in the absence of leaks. The discrepancy (residual) between the measured data and the one provided by a simulator of the network in normal operation is used to extrapolate the possible residuals in the different leak scenarios. In addition, indicators for assessing the effect of uncertainty in the performance of leak localization methods based on residual correlation analysis are provided. The error in terms of correlation intervals and leak localzation assessment between the proposed approximation and the real one is studied by means a simplified model of the WDN of Hanoi (Vietnam).Postprint (published version

    Clustering techniques applied to sensor placement for leak detection and location in water distribution networks

    Get PDF
    This work presents an optimization strategy that maximizes the leak locatability performance of water distribution networks (WDN). The goal is to characterize and determine a sensor configuration that guarantees a maximum degree of locatability while the sensor configuration cost satisfies a budgetary constraint. The method is based on pressure sensitivity matrix analysis and an exhaustive search strategy. In order to reduce the size and the complexity of the problem the present work proposes to combine this methodology with clustering techniques. The strategy developed in this work is successfully applied to determine the optimal set of pressure sensors that should be installed in a district metered area (DMA) in the Barcelona WDN.Peer ReviewedPostprint (published version

    Dynamic Modeling, Sensor Placement Design, and Fault Diagnosis of Nuclear Desalination Systems

    Get PDF
    Fault diagnosis of sensors, devices, and equipment is an important topic in the nuclear industry for effective and continuous operation of nuclear power plants. All the fault diagnostic approaches depend critically on the sensors that measure important process variables. Whenever a process encounters a fault, the effect of the fault is propagated to some or all the process variables. The ability of the sensor network to detect and isolate failure modes and anomalous conditions is crucial for the effectiveness of a fault detection and isolation (FDI) system. However, the emphasis of most fault diagnostic approaches found in the literature is primarily on the procedures for performing FDI using a given set of sensors. Little attention has been given to actual sensor allocation for achieving the efficient FDI performance. This dissertation presents a graph-based approach that serves as a solution for the optimization of sensor placement to ensure the observability of faults, as well as the fault resolution to a maximum possible extent. This would potentially facilitate an automated sensor allocation procedure. Principal component analysis (PCA), a multivariate data-driven technique, is used to capture the relationships in the data, and to fit a hyper-plane to the data. The fault directions for different fault scenarios are obtained from the prediction errors, and fault isolation is then accomplished using new projections on these fault directions. The effectiveness of the use of an optimal sensor set versus a reduced set for fault detection and isolation is demonstrated using this technique. Among a variety of desalination technologies, the multi-stage flash (MSF) processes contribute substantially to the desalinating capacity in the world. In this dissertation, both steady-state and dynamic simulation models of a MSF desalination plant are developed. The dynamic MSF model is coupled with a previously developed International Reactor Innovative and Secure (IRIS) model in the SIMULINK environment. The developed sensor placement design and fault diagnostic methods are illustrated with application to the coupled nuclear desalination system. The results demonstrate the effectiveness of the newly developed integrated approach to performance monitoring and fault diagnosis with optimized sensor placement for large industrial systems

    10th IFAC Symposium for Fault Detection, Supervision and Safety for Technical Processes

    Get PDF
    Producción CientíficaThis paper addresses the problem of leak localization in water distribution networks (WDN) using Fisher Discriminant Analysis (FDA). First, the paper introduces how FDA can be used for leak localization using the information of pressure measurements from the sensors available in the WDN. Then, the problem of sensor placement is considered when the proposed leak localization based on FDA is used. The proposed leak localization and sensor placement approaches based on FDA will be used using a well-known WDN case study.Este trabajo forma parte del proyecto de investigación: MINECO/FEDER: DPI2015-67341-C2-2-R

    Robust leak localization in water distribution networks using machine learning techniques

    Get PDF
    Aplicat embargament des de la data de lectura fins el 20 de desembre de 2019This PhD thesis presents a methodology to detect, estimate and localize water leaks (with the main focus in the localization problem) in water distribution networks using hydraulic models and machine learning techniques. The actual state of the art is introduced, the theoretical basis of the machine learning techniques applied are explained and the hydraulic model is also detailed. The whole methodology is presented and tested into different water distribution networks and district metered areas based on simulated and real case studies and compared with published methods. The focus of the contributions is to bring more robust methods against the uncertainties that effects the problem of leak detection, by dealing with them using the self-similarity to create features monitored by the change detection technique intersection-of-confidence-interval, and the leak localization where the problem is tackled using machine learning techniques. By using those techniques, it is expected to learn the leak behavior considering their uncertainty to be used in the diagnosis stage after the training phase. One method for the leak detection problem is presented that is able to estimate the leak size and the time that the leak has been produced. This method captures the normal, leak-free, behavior and contrast it with the new measurements in order to evaluate the state of the network. If the behavior is not normal check if it is due to a leak. To have a more robust leak detection method, a specific validation is designed to operate specifically with leaks and in the temporal region where the leak is most apparent. A methodology to extent the current model-based approach to localize water leaks by means of classifiers is proposed where the non-parametric k-nearest neighbors classifier and the parametric multi-class Bayesian classifier are proposed. A new data-driven approach to localize leaks using a multivariate regression technique without the use of hydraulic models is also introduced. This method presents a clear benefit over the model-based technique by removing the need of the hydraulic model despite of the topological information is still required. Also, the information of the expected leaks is not required since information of the expected hydraulic behavior with leak is exploited to find the place where the leak is more suitable. This method has a good performance in practice, but is very sensitive to the number of sensor in the network and their sensor placement. The proposed sensor placement techniques reduce the computational load required to take into account the amount of data needed to model the uncertainty compared with other optimization approaches while are designed to work with the leak localization problem. More precisely, the proposed hybrid feature selection technique for sensor placement is able to work with any method that can be evaluated with confusion matrix and still being specialized for the leak localization task. This last method is good for a few sensors, but lacks of precision when the number of sensors to place is large. To overcome this problem an incremental sensor placement is proposed which is better for a larger number of sensors to place but worse when the number is small.Aquesta tesi presenta una nova metodologia per a localització de fuites en xarxes de distribució d'aigua potable. Primer s'ha revisat l'estat del art actual i les bases teòriques tant de les tècniques de machine learning utilitzades al llarg de la tesi com els mètodes existents de localització de fuites. La metodologia presentada s'ha provat en diferents xarxes d'aigua simulades i reals, comparant el resultats amb altres mètodes publicats. L'objectiu principal de la contribució aportada és el de desenvolupar mètodes més robustos enfront les incerteses que afecten a la localització de fuites. En el cas de la detecció i estimació de la magnitud de la fuita, s'utilitza la tècnica self-similarity per crear els indicadors es monitoritzen amb la tècnica de detecció de canvis ("intersection-of-confidence-intervals"). En el cas de la localització de les fuites, s'han fet servir les tècniques de classificadors i interpoladors provinents del machine learning. A l'utilitzar aquestes tècniques s'espera captar el comportament de la fuita i de la incertesa per aprendre i tenir-ho en compte en la fase de la localització de la fuita. El mètode de la detecció de fallades proposat és capaç d'estimar la magnitud de la fuita i l'instant en que s'ha produït. Aquest mètode captura el comportament normal, sense fuita, i el contrasta amb les noves mesures per avaluar l'estat de la xarxa. En el cas que el comportament no sigui el normal, es procedeix a comprovar si això és degut a una fuita. Per tenir una mètode de detecció més robust, es fa servir una capa de validació especialment dissenyada per treballar específicament amb fuites i en la regió temporal en que la fuita és més evident. Per tal de millorar l'actual metodologia de localització de fuites mitjançant models hidràulics s'ha proposat l'ús de classificadors. Per una banda es proposa el classificador no paramètric k-nearest neighbors i per l'altre banda el classificador Bayesià paramètric per múltiples classes. Finalment, s'ha desenvolupat un nou mètode de localització de fuites basat en models de dades mitjançant la regressió de múltiples paràmetres sense l'ús del model hidràulic de la xarxa. Finalment, s'ha tractat el problema de la col·locació de sensors. El rendiment de la localització de fuites està relacionada amb la col·locació de sensors i és particular per a cada mètode de localització. Amb l'objectiu de maximitzar el rendiment dels mètodes de localització de fuites presentats anteriorment, es presenten i avaluen tècniques de col·locació de sensors específicament dissenyats ja que el problema de combinatòria no es pot manejar intentant cada possible combinació de sensors a part de les xarxes més petites amb pocs sensors per instal·lar. Aquestes tècniques de col·locació de sensors exploten el potencial de les tècniques de selecció de variables per tal de realitzar la tasca desitjada.Esta tesis doctoral presenta una nueva metodología para detectar, estimar el tamaño y localizar fugas de agua (donde el foco principal está puesto en el problema de la localización de fugas) en redes de distribución de agua potable. La tesis presenta una revisión del estado actual y las bases de las técnicas de machine learning que se aplican, así como una explicación del modelo hidráulico de las redes de agua. El conjunto de la metodología se presenta y prueba en diferentes redes de distribución de agua y sectores de consumo con casos de estudio simulados y reales, y se compara con otros métodos ya publicados. La contribución principal es la de desarrollar métodos más robustos frente a la incertidumbre de los datos. En la detección de fugas, la incertidumbre se trata con la técnica del self-similarity para la generación de indicadores que luego son monitoreados per la técnica de detección de cambios conocida como intersection-of-confidece-interval. En la localización de fugas el problema de la incertidumbre se trata con técnicas de machine learning. Al utilizar estas técnicas se espera aprender el comportamiento de la fuga y su incertidumbre asociada para tenerlo en cuenta en la fase de diagnóstico. El método presentado para la detección de fugas tiene la habilidad de estimar la magnitud y el instante en que la fuga se ha producido. Este método captura el comportamiento normal, sin fugas, del sistema y lo contrasta con las nuevas medidas para evaluar el estado actual de la red. En el caso de que el comportamiento no sea el normal, se comprueba si es debido a la presencia de una fuga en el sistema. Para obtener un método de detección más robusto, se considera una capa de validación especialmente diseñada para trabajar específicamente con fugas y durante el periodo temporal donde la fuga es más evidente. Esta técnica se compara con otras ya publicadas proporcionando una detección más fiable, especialmente en el caso de fugas pequeñas, al mismo tiempo que proporciona más información que puede ser usada en la fase de la localización de la fuga permitiendo mejorarla. El principal problema es que el método es más lento que los otros métodos analizados. Con el fin de mejorar la actual metodología de localización de fugas mediante modelos hidráulicos, se propone la utilización de clasificadores. Concretamente, se propone el clasificador no paramétrico k-nearest neighbors y el clasificador Bayesiano paramétrico para múltiples clases. La propuesta de localización de fugas mediante modelos hidráulicos y clasificadores permite gestionar la incertidumbre de los datos mejor para obtener un diagnóstico de la localización de la fuga más preciso. El principal inconveniente recae en el coste computacional, aunque no se realiza en tiempo real, de los datos necesarios por el clasificador para aprender correctamente la dispersión de los datos. Además, el método es muy dependiente de la calidad del modelo hidráulico de la red. En el campo de la localización de fugas, se a propuesto un nuevo método de localización de fugas basado en modelos de datos mediante la regresión de múltiples parámetros sin el uso de modelo hidráulico. Este método presenta un claro beneficio respecto a las técnicas basadas en modelos hidráulicos ya que prescinde de su uso, aunque la información topológica de la red es aún necesaria. Además, la información del comportamiento de la red para cada fuga no es necesario, ya que el conocimiento del efecto hidráulico de una fuga en un determinado punto de la red es utilizado para la localización. Este método ha dado muy buenos resultados en la práctica, aunque es muy sensible al número de sensores y a su colocación en la red. Finalmente, se trata el problema de la colocación de sensores. El desempeño de la localización de fugas está ligado a la colocación de los sensores y es particular para cada método. Con el objetivo de maximizar el desempeño de los métodos de localización de fugas presentados, técnicas de colocación de sensores específicamente diseñados para ellos se han presentado y evaluado. Dado que el problema de combinatoria que presenta no puede ser tratado analizando todas las posibles combinaciones de sensores excepto en las redes más pequeñas con unos pocos sensores para instalar. Estas técnicas de colocación de sensores explotan el potencial de las técnicas de selección de variables para realizar la tarea deseada. Las técnicas de colocación de sensores propuestas reducen la carga computacional, requerida para tener en cuenta todos los datos necesarios para modelar bien la incertidumbre, comparado con otras propuestas de optimización al mismo tiempo que están diseñadas para trabajar en la tarea de la localización de fugas. Más concretamente, la propuesta basada en la técnica híbrida de selección de variables para la colocación de sensores es capaz de trabajar con cualquier técnica de localización de fugas que se pueda evaluar con la matriz de confusión y ser a la vez óptimo. Este método es muy bueno para la colocación de sensores, pero el rendimiento disminuye a medida que el número de sensores a colocar crece. Para evitar este problema, se propone método de colocación de sensores de forma incremental que presenta un mejor rendimiento para un número alto de sensores a colocar, aunque no es tan eficaz con pocos sensores a colocar.Postprint (published version
    corecore