1,149 research outputs found

    Recent Advances in Machine Learning Applied to Ultrasound Imaging

    Get PDF
    Machine learning (ML) methods are pervading an increasing number of fields of application because of their capacity to effectively solve a wide variety of challenging problems. The employment of ML techniques in ultrasound imaging applications started several years ago but the scientific interest in this issue has increased exponentially in the last few years. The present work reviews the most recent (2019 onwards) implementations of machine learning techniques for two of the most popular ultrasound imaging fields, medical diagnostics and non-destructive evaluation. The former, which covers the major part of the review, was analyzed by classifying studies according to the human organ investigated and the methodology (e.g., detection, segmentation, and/or classification) adopted, while for the latter, some solutions to the detection/classification of material defects or particular patterns are reported. Finally, the main merits of machine learning that emerged from the study analysis are summarized and discussed. © 2022 by the authors. Licensee MDPI, Basel, Switzerland

    Computer-Assisted Algorithms for Ultrasound Imaging Systems

    Get PDF
    Ultrasound imaging works on the principle of transmitting ultrasound waves into the body and reconstructs the images of internal organs based on the strength of the echoes. Ultrasound imaging is considered to be safer, economical and can image the organs in real-time, which makes it widely used diagnostic imaging modality in health-care. Ultrasound imaging covers the broad spectrum of medical diagnostics; these include diagnosis of kidney, liver, pancreas, fetal monitoring, etc. Currently, the diagnosis through ultrasound scanning is clinic-centered, and the patients who are in need of ultrasound scanning has to visit the hospitals for getting the diagnosis. The services of an ultrasound system are constrained to hospitals and did not translate to its potential in remote health-care and point-of-care diagnostics due to its high form factor, shortage of sonographers, low signal to noise ratio, high diagnostic subjectivity, etc. In this thesis, we address these issues with an objective of making ultrasound imaging more reliable to use in point-of-care and remote health-care applications. To achieve the goal, we propose (i) computer-assisted algorithms to improve diagnostic accuracy and assist semi-skilled persons in scanning, (ii) speckle suppression algorithms to improve the diagnostic quality of ultrasound image, (iii) a reliable telesonography framework to address the shortage of sonographers, and (iv) a programmable portable ultrasound scanner to operate in point-of-care and remote health-care applications

    Nerve Detection in Ultrasound Images Using Median Gabor Binary Pattern

    Get PDF
    International audienceUltrasound in regional anesthesia (RA) has increased in pop-ularity over the last years. The nerve localization presents a key step for RA practice, it is therefore valuable to develop a tool able to facilitate this practice. The nerve detection in the ultrasound images is a challeng-ing task, since the noise and other artifacts corrupt the visual properties of such kind of tissue. In this paper we propose a new method to address this problem. The proposed technique operates in two steps. As the me-dian nerve belongs to a hyperechoic region, the first step consists in the segmentation of this type of region using the k-means algorithm. The second step is more critical; it deals with nerve structure detection in noisy data. For that purpose, a new descriptor is developed. It combines tow methods median binary pattern (MBP) and Gabor filter to obtain the median Gabor binary pattern (MGBP). The method was tested on 173 ultrasound images of the median nerve obtained from three patients. The results showed that the proposed approach achieves better accuracy than the original MBP, Gabor descriptor and other popular descriptors

    FPGA-Based Portable Ultrasound Scanning System with Automatic Kidney Detection

    Get PDF
    Bedsides diagnosis using portable ultrasound scanning (PUS) offering comfortable diagnosis with various clinical advantages, in general, ultrasound scanners suffer from a poor signal-to-noise ratio, and physicians who operate the device at point-of-care may not be adequately trained to perform high level diagnosis. Such scenarios can be eradicated by incorporating ambient intelligence in PUS. In this paper, we propose an architecture for a PUS system, whose abilities include automated kidney detection in real time. Automated kidney detection is performed by training the Viola–Jones algorithm with a good set of kidney data consisting of diversified shapes and sizes. It is observed that the kidney detection algorithm delivers very good performance in terms of detection accuracy. The proposed PUS with kidney detection algorithm is implemented on a single Xilinx Kintex-7 FPGA, integrated with a Raspberry Pi ARM processor running at 900 MHz

    Transfer learning for diagnosis of congenital abnormalities of the kidney and urinary tract in children based on Ultrasound imaging data

    Full text link
    Classification of ultrasound (US) kidney images for diagnosis of congenital abnormalities of the kidney and urinary tract (CAKUT) in children is a challenging task. It is desirable to improve existing pattern classification models that are built upon conventional image features. In this study, we propose a transfer learning-based method to extract imaging features from US kidney images in order to improve the CAKUT diagnosis in children. Particularly, a pre-trained deep learning model (imagenet-caffe-alex) is adopted for transfer learning-based feature extraction from 3-channel feature maps computed from US images, including original images, gradient features, and distanced transform features. Support vector machine classifiers are then built upon different sets of features, including the transfer learning features, conventional imaging features, and their combination. Experimental results have demonstrated that the combination of transfer learning features and conventional imaging features yielded the best classification performance for distinguishing CAKUT patients from normal controls based on their US kidney images.Comment: Accepted paper in IEEE International Symposium on Biomedical Imaging (ISBI), 201

    Feature Analysis of Kidney Ultrasound Image in Four Different Ultrasound using Gray Level Co-occurrence Matrix (GLCM) and Intensity Histogram (IH)

    Get PDF
    Misinterpretation analysis of ultrasound images has been huge issues in the world nowadays. Lack of skills and knowledge, as well as unclear ultrasound image due to the presence of speckle noise in ultrasound, are some factors lead to this issue. In this research, we compare 188 kidney ultrasound images from four different types of ultrasound machines, named as ultrasound A, B, C and D. Image pre-processing of images which involve cropping, enhancement, and filtering are performed before manual segmentation and texture analysis process to indicates the wanted region and improve contrast in each image. Texture analysis is performed using gray level co-occurrence matrix (GLCM) and intensity histogram (IH) to find differences and similarities in kidney image texture between all ultrasounds. Four GLCM parameters, contrast, correlation, energy and homogeneity and four parameters from IH (mean, standard deviation, variance, and skewness) used to indicate the most significant features between all ultrasound machines. Results show that contrast in GLCM is the most significant features that can be extracted from all four ultrasound machines and will be used in the classification process

    Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey

    Get PDF
    corecore