8,968 research outputs found

    Meso-scale FDM material layout design strategies under manufacturability constraints and fracture conditions

    Get PDF
    In the manufacturability-driven design (MDD) perspective, manufacturability of the product or system is the most important of the design requirements. In addition to being able to ensure that complex designs (e.g., topology optimization) are manufacturable with a given process or process family, MDD also helps mechanical designers to take advantage of unique process-material effects generated during manufacturing. One of the most recognizable examples of this comes from the scanning-type family of additive manufacturing (AM) processes; the most notable and familiar member of this family is the fused deposition modeling (FDM) or fused filament fabrication (FFF) process. This process works by selectively depositing uniform, approximately isotropic beads or elements of molten thermoplastic material (typically structural engineering plastics) in a series of pre-specified traces to build each layer of the part. There are many interesting 2-D and 3-D mechanical design problems that can be explored by designing the layout of these elements. The resulting structured, hierarchical material (which is both manufacturable and customized layer-by-layer within the limits of the process and material) can be defined as a manufacturing process-driven structured material (MPDSM). This dissertation explores several practical methods for designing these element layouts for 2-D and 3-D meso-scale mechanical problems, focusing ultimately on design-for-fracture. Three different fracture conditions are explored: (1) cases where a crack must be prevented or stopped, (2) cases where the crack must be encouraged or accelerated, and (3) cases where cracks must grow in a simple pre-determined pattern. Several new design tools, including a mapping method for the FDM manufacturability constraints, three major literature reviews, the collection, organization, and analysis of several large (qualitative and quantitative) multi-scale datasets on the fracture behavior of FDM-processed materials, some new experimental equipment, and the refinement of a fast and simple g-code generator based on commercially-available software, were developed and refined to support the design of MPDSMs under fracture conditions. The refined design method and rules were experimentally validated using a series of case studies (involving both design and physical testing of the designs) at the end of the dissertation. Finally, a simple design guide for practicing engineers who are not experts in advanced solid mechanics nor process-tailored materials was developed from the results of this project.U of I OnlyAuthor's request

    Multimodal spatio-temporal deep learning framework for 3D object detection in instrumented vehicles

    Get PDF
    This thesis presents the utilization of multiple modalities, such as image and lidar, to incorporate spatio-temporal information from sequence data into deep learning architectures for 3Dobject detection in instrumented vehicles. The race to autonomy in instrumented vehicles or self-driving cars has stimulated significant research in developing autonomous driver assistance systems (ADAS) technologies related explicitly to perception systems. Object detection plays a crucial role in perception systems by providing spatial information to its subsequent modules; hence, accurate detection is a significant task supporting autonomous driving. The advent of deep learning in computer vision applications and the availability of multiple sensing modalities such as 360° imaging, lidar, and radar have led to state-of-the-art 2D and 3Dobject detection architectures. Most current state-of-the-art 3D object detection frameworks consider single-frame reference. However, these methods do not utilize temporal information associated with the objects or scenes from the sequence data. Thus, the present research hypothesizes that multimodal temporal information can contribute to bridging the gap between 2D and 3D metric space by improving the accuracy of deep learning frameworks for 3D object estimations. The thesis presents understanding multimodal data representations and selecting hyper-parameters using public datasets such as KITTI and nuScenes with Frustum-ConvNet as a baseline architecture. Secondly, an attention mechanism was employed along with convolutional-LSTM to extract spatial-temporal information from sequence data to improve 3D estimations and to aid the architecture in focusing on salient lidar point cloud features. Finally, various fusion strategies are applied to fuse the modalities and temporal information into the architecture to assess its efficacy on performance and computational complexity. Overall, this thesis has established the importance and utility of multimodal systems for refined 3D object detection and proposed a complex pipeline incorporating spatial, temporal and attention mechanisms to improve specific, and general class accuracy demonstrated on key autonomous driving data sets

    VIVE3D: Viewpoint-Independent Video Editing using 3D-Aware GANs

    Full text link
    We introduce VIVE3D, a novel approach that extends the capabilities of image-based 3D GANs to video editing and is able to represent the input video in an identity-preserving and temporally consistent way. We propose two new building blocks. First, we introduce a novel GAN inversion technique specifically tailored to 3D GANs by jointly embedding multiple frames and optimizing for the camera parameters. Second, besides traditional semantic face edits (e.g. for age and expression), we are the first to demonstrate edits that show novel views of the head enabled by the inherent properties of 3D GANs and our optical flow-guided compositing technique to combine the head with the background video. Our experiments demonstrate that VIVE3D generates high-fidelity face edits at consistent quality from a range of camera viewpoints which are composited with the original video in a temporally and spatially consistent manner.Comment: CVPR 2023. Project webpage and video available at http://afruehstueck.github.io/vive3

    Examples of works to practice staccato technique in clarinet instrument

    Get PDF
    Klarnetin staccato tekniğini güçlendirme aşamaları eser çalışmalarıyla uygulanmıştır. Staccato geçişlerini hızlandıracak ritim ve nüans çalışmalarına yer verilmiştir. Çalışmanın en önemli amacı sadece staccato çalışması değil parmak-dilin eş zamanlı uyumunun hassasiyeti üzerinde de durulmasıdır. Staccato çalışmalarını daha verimli hale getirmek için eser çalışmasının içinde etüt çalışmasına da yer verilmiştir. Çalışmaların üzerinde titizlikle durulması staccato çalışmasının ilham verici etkisi ile müzikal kimliğe yeni bir boyut kazandırmıştır. Sekiz özgün eser çalışmasının her aşaması anlatılmıştır. Her aşamanın bir sonraki performans ve tekniği güçlendirmesi esas alınmıştır. Bu çalışmada staccato tekniğinin hangi alanlarda kullanıldığı, nasıl sonuçlar elde edildiği bilgisine yer verilmiştir. Notaların parmak ve dil uyumu ile nasıl şekilleneceği ve nasıl bir çalışma disiplini içinde gerçekleşeceği planlanmıştır. Kamış-nota-diyafram-parmak-dil-nüans ve disiplin kavramlarının staccato tekniğinde ayrılmaz bir bütün olduğu saptanmıştır. Araştırmada literatür taraması yapılarak staccato ile ilgili çalışmalar taranmıştır. Tarama sonucunda klarnet tekniğin de kullanılan staccato eser çalışmasının az olduğu tespit edilmiştir. Metot taramasında da etüt çalışmasının daha çok olduğu saptanmıştır. Böylelikle klarnetin staccato tekniğini hızlandırma ve güçlendirme çalışmaları sunulmuştur. Staccato etüt çalışmaları yapılırken, araya eser çalışmasının girmesi beyni rahatlattığı ve istekliliği daha arttırdığı gözlemlenmiştir. Staccato çalışmasını yaparken doğru bir kamış seçimi üzerinde de durulmuştur. Staccato tekniğini doğru çalışmak için doğru bir kamışın dil hızını arttırdığı saptanmıştır. Doğru bir kamış seçimi kamıştan rahat ses çıkmasına bağlıdır. Kamış, dil atma gücünü vermiyorsa daha doğru bir kamış seçiminin yapılması gerekliliği vurgulanmıştır. Staccato çalışmalarında baştan sona bir eseri yorumlamak zor olabilir. Bu açıdan çalışma, verilen müzikal nüanslara uymanın, dil atış performansını rahatlattığını ortaya koymuştur. Gelecek nesillere edinilen bilgi ve birikimlerin aktarılması ve geliştirici olması teşvik edilmiştir. Çıkacak eserlerin nasıl çözüleceği, staccato tekniğinin nasıl üstesinden gelinebileceği anlatılmıştır. Staccato tekniğinin daha kısa sürede çözüme kavuşturulması amaç edinilmiştir. Parmakların yerlerini öğrettiğimiz kadar belleğimize de çalışmaların kaydedilmesi önemlidir. Gösterilen azmin ve sabrın sonucu olarak ortaya çıkan yapıt başarıyı daha da yukarı seviyelere çıkaracaktır

    Towards personalized immunotherapy : development of in vitro models for imaging natural killer cell behavior in the tumor microenvironment

    Get PDF
    Tremendous advances in the tumor immunology field have transformed immunotherapy from a promising approach to a standard clinical practice. However, a subset of cancer patients is non-responsive to immunotherapy. More research is therefore needed to understand the mechanisms underlying tumor resistance to immunotherapeutic treatments. The aim of this doctoral work was to develop new tools to study the mechanisms of cancer immunosurveillance and to test immunotherapeutic treatments in vitro. In this thesis, I describe the methods developed, and I discuss the main biological findings obtained by using these methods. The thesis is organized as follows. A short historical background of immunotherapy is provided in Chapter 1. Chapter 2 describes the principles of NK cell-mediated cancer immunosurveillance, and provides an overview on rare cancers, mainly focusing on sarcoma. The research aims are listed in Chapter 3. In Chapter 4, I describe the cell culture methods and cell analysis techniques relevant for my doctoral work. In Chapter 5, I describe the methods we developed to culture tumor spheroids in vitro using ultrasonic standing waves in microwell chips, focusing on the theory, design, and applications. Chapter 6 and Chapter 7 focus on the biological findings obtained using our platform in combination with traditional immunological methods, followed by future implementations discussed in Chapter 8. The constituent papers are provided at the end of the thesis. In Paper I, we combined the use of the microwell chip, ultrasonic standing waves and a protein-repellent polymer coating to enable the production of spheroids from multiple cell types. In absence of cell adhesion to the chip, spheroids could be collected and further analyzed by off-the-chip techniques. In Paper II, we designed a novel multichambered microwell chip to perform multiplexed fluorescence screening of two- or three-dimensional cell cultures. The platform allows the direct assessment of drug or immune cell cytotoxic efficacy, making it a promising tool for individualized cytotoxicity tests for personalized medicine. In Paper III, we investigate the function of PVR receptors in NK cells interacting with renal carcinoma spheroids, and the impact of PVR in NK cell-based cellular immunotherapy. We demonstrated that variations in PVR expression are primarily recognized by the inhibitory receptor TIGIT, while DNAM-1 strongly contributes to NK cell activation mainly through PVR-independent mechanisms. We performed NK cell-based cytotoxicity assays against renal carcinoma spheroids in the microwell chip. Anti-TIGIT treatment was effective only for TIGIThigh NK cells both when used as monotherapy or in combination with other drugs, suggesting that only a fraction of patients might respond to anti-TIGIT therapy. In Paper IV, a similar approach was used with primary sarcomas. We cultured patient-derived sarcoma spheroids and tested NK cell-based immunotherapy in the microwell chip, either alone or in combination with antibody therapy, and we identified promising treatment combinations. In Paper V, we applied the use of expansion microscopy to visualize NK cells infiltrating renal carcinoma spheroids. In conclusion, our multi-disciplinary work shows the development of new imaging-based platform and its use to study the mechanisms of NK cell-mediated tumor surveillance and for personalized therapy

    Towards ultrasound full-waveform inversion in medical imaging

    Get PDF
    Ultrasound imaging is a front-line clinical modality with a wide range of applications. However, there are limitations to conventional methods for some medical imaging problems, including the imaging of the intact brain. The goal of this thesis is to explore and build on recent technological advances in ultrasonics and related areas such as geophysics, including the ultrasound data parallel acquisition hardware, advanced computational techniques for field modelling and for inverse problem solving. With the significant increase in the computational power now available, a particular focus will be put on exploring the potential of full-waveform inversion (FWI), a high-resolution image reconstruction technique which has shown significant success in seismic exploration, for medical imaging applications. In this thesis a range of technologies and systems have been developed in order to improve ultrasound imaging by taking advantage of these recent advances. In the first part of this thesis the application of dual frequency ultrasound for contrast enhanced imaging of neurovasculature in the mouse brain is investigated. Here we demonstrated a significant improvement in the contrast-to-tissue ratio that could be achieved by using a multi-probe, dual frequency imaging system when compared to a conventional approach using a single high frequency probe. However, without a sufficiently accurate calibration method to determine the positioning of these probes the image resolution was found to be significantly reduced. To mitigate the impact of these positioning errors, a second study was carried out to develop a sophisticated dual probe ultrasound tomography acquisition system with a robust methodology for the calibration of transducer positions. This led to a greater focus on the development of ultrasound tomography applications in medical imaging using FWI. A 2.5D brain phantom was designed that consisted of a soft tissue brain model surrounded by a hard skull mimicking material to simulate a transcranial imaging problem. This was used to demonstrate for the first time, as far as we are aware, the experimental feasibility of imaging the brain through skull using FWI. Furthermore, to address the lack of broadband sensors available for medical FWI reconstruction applications, a deep learning neural network was proposed for the bandwidth extension of observed narrowband data. A demonstration of this proposed technique was then carried out by improving the FWI image reconstruction of experimentally acquired breast phantom imaging data. Finally, the FWI imaging method was expanded for3D neuroimaging applications and an in silico feasibility of reconstructing the mouse brain with commercial transducers is demonstrated.Open Acces

    Cost-effective non-destructive testing of biomedical components fabricated using additive manufacturing

    Get PDF
    Biocompatible titanium-alloys can be used to fabricate patient-specific medical components using additive manufacturing (AM). These novel components have the potential to improve clinical outcomes in various medical scenarios. However, AM introduces stability and repeatability concerns, which are potential roadblocks for its widespread use in the medical sector. Micro-CT imaging for non-destructive testing (NDT) is an effective solution for post-manufacturing quality control of these components. Unfortunately, current micro-CT NDT scanners require expensive infrastructure and hardware, which translates into prohibitively expensive routine NDT. Furthermore, the limited dynamic-range of these scanners can cause severe image artifacts that may compromise the diagnostic value of the non-destructive test. Finally, the cone-beam geometry of these scanners makes them susceptible to the adverse effects of scattered radiation, which is another source of artifacts in micro-CT imaging. In this work, we describe the design, fabrication, and implementation of a dedicated, cost-effective micro-CT scanner for NDT of AM-fabricated biomedical components. Our scanner reduces the limitations of costly image-based NDT by optimizing the scanner\u27s geometry and the image acquisition hardware (i.e., X-ray source and detector). Additionally, we describe two novel techniques to reduce image artifacts caused by photon-starvation and scatter radiation in cone-beam micro-CT imaging. Our cost-effective scanner was designed to match the image requirements of medium-size titanium-alloy medical components. We optimized the image acquisition hardware by using an 80 kVp low-cost portable X-ray unit and developing a low-cost lens-coupled X-ray detector. Image artifacts caused by photon-starvation were reduced by implementing dual-exposure high-dynamic-range radiography. For scatter mitigation, we describe the design, manufacturing, and testing of a large-area, highly-focused, two-dimensional, anti-scatter grid. Our results demonstrate that cost-effective NDT using low-cost equipment is feasible for medium-sized, titanium-alloy, AM-fabricated medical components. Our proposed high-dynamic-range strategy improved by 37% the penetration capabilities of an 80 kVp micro-CT imaging system for a total x-ray path length of 19.8 mm. Finally, our novel anti-scatter grid provided a 65% improvement in CT number accuracy and a 48% improvement in low-contrast visualization. Our proposed cost-effective scanner and artifact reduction strategies have the potential to improve patient care by accelerating the widespread use of patient-specific, bio-compatible, AM-manufactured, medical components

    Annals [...].

    Get PDF
    Pedometrics: innovation in tropics; Legacy data: how turn it useful?; Advances in soil sensing; Pedometric guidelines to systematic soil surveys.Evento online. Coordenado por: Waldir de Carvalho Junior, Helena Saraiva Koenow Pinheiro, Ricardo Simão Diniz Dalmolin

    The Role of Transient Vibration of the Skull on Concussion

    Get PDF
    Concussion is a traumatic brain injury usually caused by a direct or indirect blow to the head that affects brain function. The maximum mechanical impedance of the brain tissue occurs at 450±50 Hz and may be affected by the skull resonant frequencies. After an impact to the head, vibration resonance of the skull damages the underlying cortex. The skull deforms and vibrates, like a bell for 3 to 5 milliseconds, bruising the cortex. Furthermore, the deceleration forces the frontal and temporal cortex against the skull, eliminating a layer of cerebrospinal fluid. When the skull vibrates, the force spreads directly to the cortex, with no layer of cerebrospinal fluid to reflect the wave or cushion its force. To date, there is few researches investigating the effect of transient vibration of the skull. Therefore, the overall goal of the proposed research is to gain better understanding of the role of transient vibration of the skull on concussion. This goal will be achieved by addressing three research objectives. First, a MRI skull and brain segmentation automatic technique is developed. Due to bones’ weak magnetic resonance signal, MRI scans struggle with differentiating bone tissue from other structures. One of the most important components for a successful segmentation is high-quality ground truth labels. Therefore, we introduce a deep learning framework for skull segmentation purpose where the ground truth labels are created from CT imaging using the standard tessellation language (STL). Furthermore, the brain region will be important for a future work, thus, we explore a new initialization concept of the convolutional neural network (CNN) by orthogonal moments to improve brain segmentation in MRI. Second, the creation of a novel 2D and 3D Automatic Method to Align the Facial Skeleton is introduced. An important aspect for further impact analysis is the ability to precisely simulate the same point of impact on multiple bone models. To perform this task, the skull must be precisely aligned in all anatomical planes. Therefore, we introduce a 2D/3D technique to align the facial skeleton that was initially developed for automatically calculating the craniofacial symmetry midline. In the 2D version, the entire concept of using cephalometric landmarks and manual image grid alignment to construct the training dataset was introduced. Then, this concept was extended to a 3D version where coronal and transverse planes are aligned using CNN approach. As the alignment in the sagittal plane is still undefined, a new alignment based on these techniques will be created to align the sagittal plane using Frankfort plane as a framework. Finally, the resonant frequencies of multiple skulls are assessed to determine how the skull resonant frequency vibrations propagate into the brain tissue. After applying material properties and mesh to the skull, modal analysis is performed to assess the skull natural frequencies. Finally, theories will be raised regarding the relation between the skull geometry, such as shape and thickness, and vibration with brain tissue injury, which may result in concussive injury
    corecore