97 research outputs found
Micro Electromechanical Systems (MEMS) Based Microfluidic Devices for Biomedical Applications
Micro Electromechanical Systems (MEMS) based microfluidic devices have gained popularity in biomedicine field over the last few years. In this paper, a comprehensive overview of microfluidic devices such as micropumps and microneedles has been presented for biomedical applications. The aim of this paper is to present the major features and issues related to micropumps and microneedles, e.g., working principles, actuation methods, fabrication techniques, construction, performance parameters, failure analysis, testing, safety issues, applications, commercialization issues and future prospects. Based on the actuation mechanisms, the micropumps are classified into two main types, i.e., mechanical and non-mechanical micropumps. Microneedles can be categorized according to their structure, fabrication process, material, overall shape, tip shape, size, array density and application. The presented literature review on micropumps and microneedles will provide comprehensive information for researchers working on design and development of microfluidic devices for biomedical applications
Implantable Microsystem Technologies For Nanoliter-Resolution Inner Ear Drug Delivery
Advances in protective and restorative biotherapies have created new opportunities to use site-directed, programmable drug delivery systems to treat auditory and vestibular disorders. Successful therapy development that leverages the transgenic, knock-in, and knock-out variants of mouse models of human disease requires advanced microsystems specifically designed to function with nanoliter precision and with system volumes suitable for implantation. The present work demonstrates a novel biocompatible, implantable, and scalable microsystem consisted of a thermal phase-change peristaltic micropump with wireless control and a refillable reservoir. The micropump is fabricated around a catheter microtubing (250 μm OD, 125 μm ID) that provided a biocompatible leak-free flow path while avoiding complicated microfluidic interconnects. Direct-write micro-scale printing technology was used to build the mechanical components of the pump around the microtubing directly on the back of a printed circuit board assembly. In vitro characterization results indicated nanoliter resolution control over the desired flow rates of 10–100 nL/min by changing the actuation frequency, with negligible deviations in presence of up to 10× greater than physiological backpressures and ±3°C ambient temperature variation. A biocompatibility study was performed to evaluate material suitability for chronic subcutaneous implantation and clinical translational development. A stand-alone, refillable, in-plane, scalable, and fully implantable microreservoir platform was designed and fabricated to be integrated with the micropump. The microreservoir consists two main components: a cavity for storing the drug and a septum for refilling. The cavity membrane is fabricated with thin Parylene-C layers, using a polyethylene glycol (PEG) sacrificial layer. The septum thickness is minimized by pre-compression down to 1 mm. The results of in vitro characterization indicated negligible restoring force for the optimized cavity membrane and thousands of punctures through the septum without leakage. The micropump and microreservoir were integrated into microsystems which were implanted in mice. The microtubing was implanted into the round window membrane niche for infusion of a known ototoxic compound (sodium salicylate) at 50 nL/min for 20 min. Real-time shifts in distortion product otoacoustic emission thresholds and amplitudes were measured during the infusion. The results match with syringe pump gold standard. For the first time a miniature and yet scalable microsystem for inner ear drug delivery was developed, enabling drug discovery opportunities and translation to human
Microdosing for drug delivery application—A review
There is an increasing amount of research on microfluidic actuators with the aim to improve drug dosing applications. Micropumps are promising as they reduce the size and energy consumption of dosing concepts and enable new therapies. Even though there are evident advantages, there are only few examples of industrial microdosing units and micropump technology has not yet found widespread application. To answer the evoked question of what limits the application of microdosing technology for drug delivery, this work provides a comprehensive insight into the subject of drug dosing. We highlight and analyse specific microfluidic challenges and requirements in medical dosing: safety relevant aspects, such as prevention of freeflow and backflow; dosing-specific requirements, such as dosing precision and stability; and system-specific aspects, such as size, weight, and power restrictions or economic aspects. Based on these requirements, we evaluate the suitability of different mechanical micropumps and actuation mechanisms for drug administration. In addition to research work, we present industrial microdosing systems that are commercially available or close to market release. We then summarize outstanding technical solutions that ensure sufficient fluidic performance, guarantee a safe use, and fulfil the specific requirements of medical microdosing
Bucky gel actuator for morphing applications
Since the demonstration of Bucky Gel Actuator (BGA) in 2005, a great deal of effort has been exerted to develop novel applications for electro-active morphing materials. Three-layered bimorph nanocomposite has become an excellent candidate for morphing applications since it can be easily fabricated, operated in air, and driven with few volts. There has been limited published study on the mechanical properties of BGA. In this study, the effect of three parameters: layer thickness, carbon nanotube type, and weight fraction of components, on the mechanical properties was investigated. Samples were characterized via nano-indentation and DMA. It was found that BGA composed of 22 wt% single-walled carbon nanotubes and 45 wt% ionic liquid exhibited the highest hardness, adhesion, elastic and storage moduli. Most of BGA potential applications would require control over one BGA output: displacement. In this study, various sets of experiments were designed to investigate the effect of several parameters on the maximum lateral displacement of BGA. Two input parameters: voltage and frequency, and three material/design parameters: carbon nanotube type, thickness, and weight fraction of constituents, were selected. A new thickness ratio term was also introduced to study the role of individual layers on BGA displacement. In addition, an important factor in the design of BGA-based devices, lifetime, was investigated. Finally, possible degradation of BGA was studied by repeating displacement measurements after several weeks of being stored. Based on displacement studies, a new model was established utilizing nonlinear regression to predict BGA maximum displacement based on the effect of these parameters. This model was verified by comparing its predictions with other reported results in the literature. The model displayed a very good fit with various reported cases of BGA samples made with different types of CNT and ionic liquid. Microfluidics is a promising field of application for BGA. A brief literature review on the electroactive mechanisms used in microfluidics is presented. Preliminary force studies proved that BGA has the capability to be employed as a microvalve. A flow regulator utilizing a BGA microvalve was designed and fabricated. Flow rate measurements showed the capability of BGA-valve in manipulating the flow rate in different ranges
Frequency-controlled wireless passive microfluidic devices
Microfluidics is a promising technology that is increasingly attracting the attention of researchers due to its high efficiency and low-cost features. Micropumps, micromixers, and microvalves have been widely applied in various biomedical applications due to their compact size and precise dosage controllability. Nevertheless, despite the vast amount of research reported in this research area, the ability to implement these devices in portable and implantable applications is still limited. To date, such devices are constricted to the use of wires, or on-board power supplies, such as batteries. This thesis presents novel techniques that allow wireless control of passive microfluidic devices using an external radiofrequency magnetic field utilizing thermopneumatic principle. Three microfluidic devices are designed and developed to perform within the range of implantable drug-delivery devices. To demonstrate the wireless control of microfluidic devices, a wireless implantable thermopneumatic micropump is presented. Thermopneumatic pumping with a maximum flow rate of 2.86 μL/min is realized using a planar wirelessly-controlled passive inductor-capacitor heater. Then, this principle was extended in order to demonstrate the selective wireless control of multiple passive heaters. A passive wirelessly-controlled thermopneumatic zigzag micromixer is developed as a mean of a multiple drug delivery device. A maximum mixing efficiency of 96.1% is achieved by selectively activating two passive wireless planar inductor-capacitor heaters that have different resonant frequency values. To eliminate the heat associated with aforementioned wireless devices, a wireless piezoelectric normally-closed microvalve for drug delivery applications is developed. A piezoelectric diaphragm is operated wirelessly using the wireless power that is transferred from an external magnetic field. Valving is achieved with a percentage error as low as 3.11% in a 3 days long-term functionality test. The developed devices present a promising implementation of the reported wireless actuation principles in various portable and implantable biomedical applications, such as drug delivery, analytical assays, and cell lysis devices
Master of Science
thesisThis thesis presents the design and optimization of a biologically inspired wet shape memory alloy (SMA) actuated pump that can provide thermal energy via fluidic convection to actuate external wet SMA subsystems. Furthermore, the pump draws from its own fluidic output to assist in the actuation of its own internal SMA actuators. A thorough analysis of the previous wet SMA robotic heart is conducted by searching for opportunities for improvement. Methods of improving the pump's output-to-input ratio included modifying the pumping chambers, actuation cycle timing, implementing electrical actuation, and continuously adding heat to the system. Dynamic modeling was performed to provide a baseline indicator of what was to be expected during actual implementation and testing. The effects of changing various parameters were explored to determine optimal configurations. Key parameters affecting performance include mechanical advantage, actuator length, flow durations, and water temperature. Implemented design changes and testing confirmed the modeling results. Continuous heating of the hot water within the pressurized accumulator greatly enhanced the pump's performance. Using only fluidic induced actuation, the output-to-input ratio peaked at 1.4. The pump reached an output-to-input ratio of 2.1 with the aid of electrical actuation. This is the first successful implementation of a self-sustaining thermofluidically powered SMA pump. Furthermore, unlike other SMA micropumps that typically output 1 mL/min or less, this pump is capable of a macroscale net output of 66 mL/min. While the pump's output exceeds the required input, the power efficiency and power density of the pump do not compare to that of the human heart due to the amount of power required to keep the hot water continuously heated. Viable options for improving efficiency and power density include minimizing pump mass, optimizing pumping chamber design, and reducing the amount of heat necessary to keep the hot water at an elevated temperature
Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges
Wireless capsule endoscopy (WCE) offers a feasible noninvasive way to detect the whole gastrointestinal (GI) tract and revolutionizes the diagnosis technology. However, compared with wired endoscopies, the limited working time, the low frame rate, and the low image resolution limit the wider application. The progress of this new technology is reviewed in this paper, and the evolution tendencies are analyzed to be high image resolution, high frame rate, and long working time. Unfortunately, the power supply of capsule endoscope (CE) is the bottleneck. Wireless power transmission (WPT) is the promising solution to this problem, but is also the technical challenge. Active CE is another tendency and will be the next geneion of the WCE. Nevertheless, it will not come true shortly, unless the practical locomotion mechanism of the active CE in GI tract is achieved. The locomotion mechanism is the other technical challenge, besides the challenge of WPT. The progress about the WPT and the active capsule technology is reviewed
Multi-Functional System for Biomedical Application Using AC Electrokinetics
Manipulation of fluids in a small volume is often a challenge in the field of Microfluidics. While many research groups have addressed this issue with robust methodologies, manipulating fluids remains a scope of study due to the ever-changing technology (Processing Tools) and increase in the demand for “Lab-On-a-Chip” devices in biological applications. This thesis peruses the flow pattern of the orthogonal electrode pattern and circular electrode providing, examples of the flow patterns and the process micromixing. Characteristics of a multifunctional system were demonstrated using orthogonal electrode and circular electrode patterned device. Conductivity of the fluids were chosen such they reflect perfect biological conditions to determine the working conditions of the proposed devices under different AC voltage and frequency levels. Experimental results were then compared with simulated results which were obtained using COMSOL simulation software
DESIGN AND OPTIMIZATION OF PERISTALTIC MICROPUMPS USING EVOLUTIONARY ALGORITHMS
A design optimization based on coupled solid–fluid analysis is investigated in this work to achieve specific flow rate through a peristaltic micropump. A micropump consisting of four pneumatically actuated nozzle/diffuser shaped moving actuators on the sidewalls is considered for numerical study. These actuators are used to create pressure difference in the four pump chambers, which in turn drives the fluid through the pump in one direction. Genetic algorithms along with artificial neural networks are used for optimizing the pump geometry and the actuation frequency. A simple example with moving walls is considered for validation by developing an exact analytical solution of Navier–Stokes equation and comparing it with numerical simulations. Possible applications of these pumps are in microelectronics cooling and drug delivery. Based on the results obtained from the fluid–structure interaction analysis, three optimized geometries result in flow rates which match the predicted flow rates with 95% accuracy. These geometries need further investigation for fabrication and manufacturing issues
- …