157 research outputs found

    Accessibility of Health Data Representations for Older Adults: Challenges and Opportunities for Design

    Get PDF
    Health data of consumer off-the-shelf wearable devices is often conveyed to users through visual data representations and analyses. However, this is not always accessible to people with disabilities or older people due to low vision, cognitive impairments or literacy issues. Due to trade-offs between aesthetics predominance or information overload, real-time user feedback may not be conveyed easily from sensor devices through visual cues like graphs and texts. These difficulties may hinder critical data understanding. Additional auditory and tactile feedback can also provide immediate and accessible cues from these wearable devices, but it is necessary to understand existing data representation limitations initially. To avoid higher cognitive and visual overload, auditory and haptic cues can be designed to complement, replace or reinforce visual cues. In this paper, we outline the challenges in existing data representation and the necessary evidence to enhance the accessibility of health information from personal sensing devices used to monitor health parameters such as blood pressure, sleep, activity, heart rate and more. By creating innovative and inclusive user feedback, users will likely want to engage and interact with new devices and their own data

    Evaluating footwear “in the wild”: Examining wrap and lace trail shoe closures during trail running

    Get PDF
    Trail running participation has grown over the last two decades. As a result, there have been an increasing number of studies examining the sport. Despite these increases, there is a lack of understanding regarding the effects of footwear on trail running biomechanics in ecologically valid conditions. The purpose of our study was to evaluate how a Wrap vs. Lace closure (on the same shoe) impacts running biomechanics on a trail. Thirty subjects ran a trail loop in each shoe while wearing a global positioning system (GPS) watch, heart rate monitor, inertial measurement units (IMUs), and plantar pressure insoles. The Wrap closure reduced peak foot eversion velocity (measured via IMU), which has been associated with fit. The Wrap closure also increased heel contact area, which is also associated with fit. This increase may be associated with the subjective preference for the Wrap. Lastly, runners had a small but significant increase in running speed in the Wrap shoe with no differences in heart rate nor subjective exertion. In total, the Wrap closure fit better than the Lace closure on a variety of terrain. This study demonstrates the feasibility of detecting meaningful biomechanical differences between footwear features in the wild using statistical tools and study design. Evaluating footwear in ecologically valid environments often creates additional variance in the data. This variance should not be treated as noise; instead, it is critical to capture this additional variance and challenges of ecologically valid terrain if we hope to use biomechanics to impact the development of new products

    Novel Bidirectional Body - Machine Interface to Control Upper Limb Prosthesis

    Get PDF
    Objective. The journey of a bionic prosthetic user is characterized by the opportunities and limitations involved in adopting a device (the prosthesis) that should enable activities of daily living (ADL). Within this context, experiencing a bionic hand as a functional (and, possibly, embodied) limb constitutes the premise for mitigating the risk of its abandonment through the continuous use of the device. To achieve such a result, different aspects must be considered for making the artificial limb an effective support for carrying out ADLs. Among them, intuitive and robust control is fundamental to improving amputees’ quality of life using upper limb prostheses. Still, as artificial proprioception is essential to perceive the prosthesis movement without constant visual attention, a good control framework may not be enough to restore practical functionality to the limb. To overcome this, bidirectional communication between the user and the prosthesis has been recently introduced and is a requirement of utmost importance in developing prosthetic hands. Indeed, closing the control loop between the user and a prosthesis by providing artificial sensory feedback is a fundamental step towards the complete restoration of the lost sensory-motor functions. Within my PhD work, I proposed the development of a more controllable and sensitive human-like hand prosthesis, i.e., the Hannes prosthetic hand, to improve its usability and effectiveness. Approach. To achieve the objectives of this thesis work, I developed a modular and scalable software and firmware architecture to control the Hannes prosthetic multi-Degree of Freedom (DoF) system and to fit all users’ needs (hand aperture, wrist rotation, and wrist flexion in different combinations). On top of this, I developed several Pattern Recognition (PR) algorithms to translate electromyographic (EMG) activity into complex movements. However, stability and repeatability were still unmet requirements in multi-DoF upper limb systems; hence, I started by investigating different strategies to produce a more robust control. To do this, EMG signals were collected from trans-radial amputees using an array of up to six sensors placed over the skin. Secondly, I developed a vibrotactile system to implement haptic feedback to restore proprioception and create a bidirectional connection between the user and the prosthesis. Similarly, I implemented an object stiffness detection to restore tactile sensation able to connect the user with the external word. This closed-loop control between EMG and vibration feedback is essential to implementing a Bidirectional Body - Machine Interface to impact amputees’ daily life strongly. For each of these three activities: (i) implementation of robust pattern recognition control algorithms, (ii) restoration of proprioception, and (iii) restoration of the feeling of the grasped object's stiffness, I performed a study where data from healthy subjects and amputees was collected, in order to demonstrate the efficacy and usability of my implementations. In each study, I evaluated both the algorithms and the subjects’ ability to use the prosthesis by means of the F1Score parameter (offline) and the Target Achievement Control test-TAC (online). With this test, I analyzed the error rate, path efficiency, and time efficiency in completing different tasks. Main results. Among the several tested methods for Pattern Recognition, the Non-Linear Logistic Regression (NLR) resulted to be the best algorithm in terms of F1Score (99%, robustness), whereas the minimum number of electrodes needed for its functioning was determined to be 4 in the conducted offline analyses. Further, I demonstrated that its low computational burden allowed its implementation and integration on a microcontroller running at a sampling frequency of 300Hz (efficiency). Finally, the online implementation allowed the subject to simultaneously control the Hannes prosthesis DoFs, in a bioinspired and human-like way. In addition, I performed further tests with the same NLR-based control by endowing it with closed-loop proprioceptive feedback. In this scenario, the results achieved during the TAC test obtained an error rate of 15% and a path efficiency of 60% in experiments where no sources of information were available (no visual and no audio feedback). Such results demonstrated an improvement in the controllability of the system with an impact on user experience. Significance. The obtained results confirmed the hypothesis of improving robustness and efficiency of a prosthetic control thanks to of the implemented closed-loop approach. The bidirectional communication between the user and the prosthesis is capable to restore the loss of sensory functionality, with promising implications on direct translation in the clinical practice

    Retainer-Free Optopalatographic Device Design and Evaluation as a Feedback Tool in Post-Stroke Speech and Swallowing Therapy

    Get PDF
    Stroke is one of the leading causes of long-term motor disability, including oro-facial impairments which affect speech and swallowing. Over the last decades, rehabilitation programs have evolved from utilizing mainly compensatory measures to focusing on recovering lost function. In the continuing effort to improve recovery, the concept of biofeedback has increasingly been leveraged to enhance self-efficacy, motivation and engagement during training. Although both speech and swallowing disturbances resulting from oro-facial impairments are frequent sequelae of stroke, efforts to develop sensing technologies that provide comprehensive and quantitative feedback on articulator kinematics and kinetics, especially those of the tongue, and specifically during post-stroke speech and swallowing therapy have been sparse. To that end, such a sensing device needs to accurately capture intraoral tongue motion and contact with the hard palate, which can then be translated into an appropriate form of feedback, without affecting tongue motion itself and while still being light-weight and portable. This dissertation proposes the use of an intraoral sensing principle known as optopalatography to provide such feedback while also exploring the design of optopalatographic devices itself for use in dysphagia and dysarthria therapy. Additionally, it presents an alternative means of holding the device in place inside the oral cavity with a newly developed palatal adhesive instead of relying on dental retainers, which previously limited device usage to a single person. The evaluation was performed on the task of automatically classifying different functional tongue exercises from one another with application in dysphagia therapy, whereas a phoneme recognition task was conducted with application in dysarthria therapy. Results on the palatal adhesive suggest that it is indeed a valid alternative to dental retainers when device residence time inside the oral cavity is limited to several tens of minutes per session, which is the case for dysphagia and dysarthria therapy. Functional tongue exercises were classified with approximately 61 % accuracy across subjects, whereas for the phoneme recognition task, tense vowels had the highest recognition rate, followed by lax vowels and consonants. In summary, retainer-free optopalatography has the potential to become a viable method for providing real-time feedback on tongue movements inside the oral cavity, but still requires further improvements as outlined in the remarks on future development.:1 Introduction 1.1 Motivation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Problem statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.3 Goals and contributions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.4 Scope and limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Basics of post-stroke speech and swallowing therapy 2.1 Dysarthria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.2 Dysphagia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.3 Treatment rationale and potential of biofeedback . . . . . . . . . . . . . . . . . 13 2.4 Summary and conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3 Tongue motion sensing 3.1 Contact-based methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 3.1.1 Electropalatography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 3.1.2 Manometry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.1.3 Capacitive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.2 Non-contact based methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.2.1 Electromagnetic articulography . . . . . . . . . . . . . . . . . . . . . . . 23 3.2.2 Permanent magnetic articulography . . . . . . . . . . . . . . . . . . . . 24 3.2.3 Optopalatography (related work) . . . . . . . . . . . . . . . . . . . . . . 25 3.3 Electro-optical stomatography . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.4 Extraoral sensing techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3.5 Summary, comparison and conclusion . . . . . . . . . . . . . . . . . . . . . . . 29 4 Fundamentals of optopalatography 4.1 Important radiometric quantities . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.1.1 Solid angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.1.2 Radiant flux and radiant intensity . . . . . . . . . . . . . . . . . . . . . 33 4.1.3 Irradiance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 4.1.4 Radiance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 4.2 Sensing principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 4.2.1 Analytical models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 4.2.2 Monte Carlo ray tracing methods . . . . . . . . . . . . . . . . . . . . . . 37 4.2.3 Data-driven models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 4.2.4 Model comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 4.3 A priori device design consideration . . . . . . . . . . . . . . . . . . . . . . . . 41 4.3.1 Optoelectronic components . . . . . . . . . . . . . . . . . . . . . . . . . 41 4.3.2 Additional electrical components and requirements . . . . . . . . . . . . 43 4.3.3 Intraoral sensor layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 5 Intraoral device anchorage 5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 5.1.1 Mucoadhesion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 5.1.2 Considerations for the palatal adhesive . . . . . . . . . . . . . . . . . . . 48 5.2 Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 5.2.1 Polymer selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 5.2.2 Fabrication method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 5.2.3 Formulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5.2.4 PEO tablets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5.2.5 Connection to the intraoral sensor’s encapsulation . . . . . . . . . . . . 50 5.2.6 Formulation evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 5.3 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 5.3.1 Initial formulation evaluation . . . . . . . . . . . . . . . . . . . . . . . . 54 5.3.2 Final OPG adhesive formulation . . . . . . . . . . . . . . . . . . . . . . 56 5.4 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 6 Initial device design with application in dysphagia therapy 6.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 6.2 Optode and optical sensor selection . . . . . . . . . . . . . . . . . . . . . . . . . 60 6.2.1 Optode and optical sensor evaluation procedure . . . . . . . . . . . . . . 61 6.2.2 Selected optical sensor characterization . . . . . . . . . . . . . . . . . . 62 6.2.3 Mapping from counts to millimeter . . . . . . . . . . . . . . . . . . . . . 62 6.2.4 Results and discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 6.3 Device design and hardware implementation . . . . . . . . . . . . . . . . . . . . 64 6.3.1 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 6.3.2 Optode placement and circuit board dimensions . . . . . . . . . . . . . 64 6.3.3 Firmware description and measurement cycle . . . . . . . . . . . . . . . 66 6.3.4 Encapsulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 6.3.5 Fully assembled OPG device . . . . . . . . . . . . . . . . . . . . . . . . 67 6.4 Evaluation on the gesture recognition task . . . . . . . . . . . . . . . . . . . . . 69 6.4.1 Exercise selection, setup and recording . . . . . . . . . . . . . . . . . . . 69 6.4.2 Data corpus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 6.4.3 Sequence pre-processing . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 6.4.4 Choice of classifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 6.4.5 Training and evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 6.4.6 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 6.5 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 7 Improved device design with application in dysarthria therapy 7.1 Device design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 7.1.1 Design considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 7.1.2 General system overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 7.1.3 Intraoral sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 7.1.4 Receiver and controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 7.1.5 Multiplexer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 7.2 Hardware implementation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 7.2.1 Optode placement and circuit board layout . . . . . . . . . . . . . . . . 87 7.2.2 Encapsulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 7.3 Device characterization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 7.3.1 Photodiode transient response . . . . . . . . . . . . . . . . . . . . . . . 91 7.3.2 Current source and rise time . . . . . . . . . . . . . . . . . . . . . . . . 91 7.3.3 Multiplexer switching speed . . . . . . . . . . . . . . . . . . . . . . . . . 92 7.3.4 Measurement cycle and firmware implementation . . . . . . . . . . . . . 93 7.3.5 In vitro measurement accuracy . . . . . . . . . . . . . . . . . . . . . . . 95 7.3.6 Optode measurement stability . . . . . . . . . . . . . . . . . . . . . . . 96 7.4 Evaluation on the phoneme recognition task . . . . . . . . . . . . . . . . . . . . 98 7.4.1 Corpus selection and recording setup . . . . . . . . . . . . . . . . . . . . 98 7.4.2 Annotation and sensor data post-processing . . . . . . . . . . . . . . . . 98 7.4.3 Mapping from counts to millimeter . . . . . . . . . . . . . . . . . . . . . 99 7.4.4 Classifier and feature selection . . . . . . . . . . . . . . . . . . . . . . . 100 7.4.5 Evaluation paradigms . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 7.5 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 7.5.1 Tongue distance curve prediction . . . . . . . . . . . . . . . . . . . . . . 105 7.5.2 Tongue contact patterns and contours . . . . . . . . . . . . . . . . . . . 105 7.5.3 Phoneme recognition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 7.6 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 8 Conclusion and future work 115 9 Appendix 9.1 Analytical light transport models . . . . . . . . . . . . . . . . . . . . . . . . . . 119 9.2 Meshed Monte Carlo method . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 9.3 Laser safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 9.4 Current source modulation voltage . . . . . . . . . . . . . . . . . . . . . . . . . 123 9.5 Transimpedance amplifier’s frequency responses . . . . . . . . . . . . . . . . . . 123 9.6 Initial OPG device’s PCB layout and circuit diagrams . . . . . . . . . . . . . . 127 9.7 Improved OPG device’s PCB layout and circuit diagrams . . . . . . . . . . . . 129 9.8 Test station layout drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 Bibliography 152Der Schlaganfall ist eine der häufigsten Ursachen für motorische Langzeitbehinderungen, einschließlich solcher im Mund- und Gesichtsbereich, deren Folgen u.a. Sprech- und Schluckprobleme beinhalten, welche sich in den beiden Symptomen Dysarthrie und Dysphagie äußern. In den letzten Jahrzehnten haben sich Rehabilitationsprogramme für die Behandlung von motorisch ausgeprägten Schlaganfallsymptomatiken substantiell weiterentwickelt. So liegt nicht mehr die reine Kompensation von verlorengegangener motorischer Funktionalität im Vordergrund, sondern deren aktive Wiederherstellung. Dabei hat u.a. die Verwendung von sogenanntem Biofeedback vermehrt Einzug in die Therapie erhalten, um Motivation, Engagement und Selbstwahrnehmung von ansonsten unbewussten Bewegungsabläufen seitens der Patienten zu fördern. Obwohl jedoch Sprech- und Schluckstörungen eine der häufigsten Folgen eines Schlaganfalls darstellen, wird diese Tatsache nicht von der aktuellen Entwicklung neuer Geräte und Messmethoden für quantitatives und umfassendes Biofeedback reflektiert, insbesondere nicht für die explizite Erfassung intraoraler Zungenkinematik und -kinetik und für den Anwendungsfall in der Schlaganfalltherapie. Ein möglicher Grund dafür liegt in den sehr strikten Anforderungen an ein solche Messmethode: Sie muss neben Portabilität idealerweise sowohl den Kontakt zwischen der Zunge und dem Gaumen, als auch die dreidimensionale Bewegung der Zunge in der Mundhöhle erfassen, ohne dabei die Artikulation selbst zu beeinflussen. Um diesen Anforderungen gerecht zu werden, wird in dieser Dissertation das Messprinzip der Optopalatographie untersucht, mit dem Schwerpunkt auf der Anwendung in der Dysarthrie- und Dysphagietherapie. Dies beinhaltet auch die Entwicklung eines entsprechenden Gerätes sowie dessen Befestigungsmethode in der Mundhöhle über ein dediziertes Mundschleimhautadhäsiv. Letzteres umgeht das bisherige Problem der notwendigen Anpassung eines solchen intraoralen Gerätes an einen einzelnen Nutzer. Für die Anwendung in der Dysphagietherapie erfolgte die Evaluation anhand einer automatischen Erkennung von Mobilisationsübungen der Zunge, welche routinemäßig in der funktionalen Dysphagietherapie durchgeführt werden. Für die Anwendung in der Dysarthrietherapie wurde eine Lauterkennung durchgeführt. Die Resultate bezüglich der Verwendung des Mundschleimhautadhäsives suggerieren, dass dieses tatsächlich eine valide Alternative zu den bisher verwendeten Techniken zur Befestigung intraoraler Geräte in der Mundhöhle darstellt. Zungenmobilisationsübungen wurden über Probanden hinweg mit einer Rate von 61 % erkannt, wogegen in der Lauterkennung Langvokale die höchste Erkennungsrate erzielten, gefolgt von Kurzvokalen und Konsonanten. Zusammenfassend lässt sich konstatieren, dass das Prinzip der Optopalatographie eine ernstzunehmende Option für die intraorale Erfassung von Zungenbewegungen darstellt, wobei weitere Entwicklungsschritte notwendig sind, welche im Ausblick zusammengefasst sind.:1 Introduction 1.1 Motivation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Problem statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.3 Goals and contributions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.4 Scope and limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Basics of post-stroke speech and swallowing therapy 2.1 Dysarthria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.2 Dysphagia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2.3 Treatment rationale and potential of biofeedback . . . . . . . . . . . . . . . . . 13 2.4 Summary and conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3 Tongue motion sensing 3.1 Contact-based methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 3.1.1 Electropalatography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 3.1.2 Manometry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 3.1.3 Capacitive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.2 Non-contact based methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.2.1 Electromagnetic articulography . . . . . . . . . . . . . . . . . . . . . . . 23 3.2.2 Permanent magnetic articulography . . . . . . . . . . . . . . . . . . . . 24 3.2.3 Optopalatography (related work) . . . . . . . . . . . . . . . . . . . . . . 25 3.3 Electro-optical stomatography . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.4 Extraoral sensing techniques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3.5 Summary, comparison and conclusion . . . . . . . . . . . . . . . . . . . . . . . 29 4 Fundamentals of optopalatography 4.1 Important radiometric quantities . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.1.1 Solid angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.1.2 Radiant flux and radiant intensity . . . . . . . . . . . . . . . . . . . . . 33 4.1.3 Irradiance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 4.1.4 Radiance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 4.2 Sensing principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 4.2.1 Analytical models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 4.2.2 Monte Carlo ray tracing methods . . . . . . . . . . . . . . . . . . . . . . 37 4.2.3 Data-driven models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 4.2.4 Model comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 4.3 A priori device design consideration . . . . . . . . . . . . . . . . . . . . . . . . 41 4.3.1 Optoelectronic components . . . . . . . . . . . . . . . . . . . . . . . . . 41 4.3.2 Additional electrical components and requirements . . . . . . . . . . . . 43 4.3.3 Intraoral sensor layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 5 Intraoral device anchorage 5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 5.1.1 Mucoadhesion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 5.1.2 Considerations for the palatal adhesive . . . . . . . . . . . . . . . . . . . 48 5.2 Methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 5.2.1 Polymer selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 5.2.2 Fabrication method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 5.2.3 Formulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5.2.4 PEO tablets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5.2.5 Connection to the intraoral sensor’s encapsulation . . . . . . . . . . . . 50 5.2.6 Formulation evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 5.3 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 5.3.1 Initial formulation evaluation . . . . . . . . . . . . . . . . . . . . . . . . 54 5.3.2 Final OPG adhesive formulation . . . . . . . . . . . . . . . . . . . . . . 56 5.4 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 6 Initial device design with application in dysphagia therapy 6.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 6.2 Optode and optical sensor selection . . . . . . . . . . . . . . . . . . . . . . . . . 60 6.2.1 Optode and optical sensor evaluation procedure . . . . . . . . . . . . . . 61 6.2.2 Selected optical sensor characterization . . . . . . . . . . . . . . . . . . 62 6.2.3 Mapping from counts to millimeter . . . . . . . . . . . . . . . . . . . . . 62 6.2.4 Results and discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 6.3 Device design and hardware implementation . . . . . . . . . . . . . . . . . . . . 64 6.3.1 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 6.3.2 Optode placement and circuit board dimensions . . . . . . . . . . . . . 64 6.3.3 Firmware description and measurement cycle . . . . . . . . . . . . . . . 66 6.3.4 Encapsulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 6.3.5 Fully assembled OPG device . . . . . . . . . . . . . . . . . . . . . . . . 67 6.4 Evaluation on the gesture recognition task . . . . . . . . . . . . . . . . . . . . . 69 6.4.1 Exercise selection, setup and recording . . . . . . . . . . . . . . . . . . . 69 6.4.2 Data corpus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 6.4.3 Sequence pre-processing . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 6.4.4 Choice of classifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 6.4.5 Training and evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 6.4.6 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 6.5 Discussion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 7 Improved device design with application in dysarthria therapy 7.1 Device design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 7.1.1 Design considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 7.1.2 General system overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 7.1.3 Intraoral sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 7.1.4 Receiver and controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 7.1.5 Multiplexer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 7.2 Hardware implementation . . . . . . . . . . . . . . . . . . . . .

    ATHENA Research Book, Volume 2

    Get PDF
    ATHENA European University is an association of nine higher education institutions with the mission of promoting excellence in research and innovation by enabling international cooperation. The acronym ATHENA stands for Association of Advanced Technologies in Higher Education. Partner institutions are from France, Germany, Greece, Italy, Lithuania, Portugal and Slovenia: University of Orléans, University of Siegen, Hellenic Mediterranean University, Niccolò Cusano University, Vilnius Gediminas Technical University, Polytechnic Institute of Porto and University of Maribor. In 2022, two institutions joined the alliance: the Maria Curie-Skłodowska University from Poland and the University of Vigo from Spain. Also in 2022, an institution from Austria joined the alliance as an associate member: Carinthia University of Applied Sciences. This research book presents a selection of the research activities of ATHENA University's partners. It contains an overview of the research activities of individual members, a selection of the most important bibliographic works of members, peer-reviewed student theses, a descriptive list of ATHENA lectures and reports from individual working sections of the ATHENA project. The ATHENA Research Book provides a platform that encourages collaborative and interdisciplinary research projects by advanced and early career researchers

    Neuromodulation and rehabilitation with brain-computer interfaces and Spinal Cord Stimulation

    Get PDF
    Consequences of spinal cord injury (SCI) are often severe and life-altering. Recovery of hand and arm function is consistently reported by SCI individuals as their greatest priority in terms of rehabilitation. Yet current strategies provide poor-to-modest outcomes. Innovation is required to improve traditional approaches to upper limb rehabilitation. The current view is that, due to the multi-faceted nature of SCI pathology, effective treatment will take a combinational approach. This thesis brings together two emerging and promising technologies—transcutaneous spinal cord stimulation (tSCS) and brain-computer interfaces (BCIs)—in order to judge their complimentary nature as tools for neurophysiological assessment and rehabilitation following SCI. There is growing evidence that cervical tSCS combined with intensive physical training can lead to lasting functional improvements in individuals with chronic SCI. The mechanisms underpinning tSCS-facilitated recovery, however, are still a matter of ongoing research, with conflicting reports of the impact of tSCS on cortical and spinal excitability. Evoked and reflexes have so far been the primary method of quantifying corticospinal excitability. The research undertaken in this thesis first explores electroencephalography (EEG) as a potential complementary method for assessing neuromodulation following tSCS. Due the novelty of the research, a preliminary investigation was undertaken to establish the feasibility of EEG monitoring during cervical tSCS. In a cohort of twenty-one able-bodied individuals, it was demonstrated that tSCS presented as low-latency, high-amplitude artefacts in EEG time series, at a rate equal to the stimulation frequency. Descriptive statistics were used to characterise the impact of tSCS, and judge the effectiveness of noise-attenuation techniques. Results showed that, with artefact-suppression, EEG recorded during tSCS could be returned to levels statistically similar to that of EEG acquired without tSCS interference. Additionally, it was established that neural components, such as the individual alpha frequency, were recoverable, demonstrating the feasibility of EEG as a tool for tracking cortical activity during tSCS. A subsequent study was conducted to investigate the neuromodulatory potential of tSCS on cortical activity. EEG was recorded during upper limb movements in 30 individuals both with and without concurrent cervical tSCS. Stimulation was delivered to the cervical region of the neck at intensities matching the individual’s highest tolerance without causing pain. It was found that cortical oscillatory dynamics were unaffected over a cohort of neurologically intact participants. However, a weak inhibitory effect was measured amoing individuals who received the highest stimulation intensities. A final study was devised to explore the potential of movement priming for tSCS-facilitated upper limb therapy in an individual with chronic AIS A cervical SCI. Movement priming was achieved by encouraging the participant to engage in repetitive bimanual hand movements with respect to their sensorimotor cortical activity as measured with EEG. A BCI provided real time feedback of the participant’s motor engagement in the form of a computer game, allowing them to actively engage regardless of impairment level. The participant first underwent an initial phase of 15 sessions of tSCS training alone followed by a second phase of 15 sessions of BCI priming and tSCS training. The participant’s strength and dexterity improved across both phases of the study. BCI priming may have contributed to an enhanced effect in some measures such as improved bilateral finger strength, but due to mixed results across functional measures no firm conclusions can be drawn. Nevertheless, the functional improvements lend greater credibility to cervical tSCS as a strategy for upper limb rehabilitation

    Human-Machine Interfaces using Distributed Sensing and Stimulation Systems

    Get PDF
    As the technology moves towards more natural human-machine interfaces (e.g. bionic limbs, teleoperation, virtual reality), it is necessary to develop a sensory feedback system in order to foster embodiment and achieve better immersion in the control system. Contemporary feedback interfaces presented in research use few sensors and stimulation units to feedback at most two discrete feedback variables (e.g. grasping force and aperture), whereas the human sense of touch relies on a distributed network of mechanoreceptors providing a wide bandwidth of information. To provide this type of feedback, it is necessary to develop a distributed sensing system that could extract a wide range of information during the interaction between the robot and the environment. In addition, a distributed feedback interface is needed to deliver such information to the user. This thesis proposes the development of a distributed sensing system (e-skin) to acquire tactile sensation, a first integration of distributed sensing system on a robotic hand, the development of a sensory feedback system that compromises the distributed sensing system and a distributed stimulation system, and finally the implementation of deep learning methods for the classification of tactile data. It\u2019s core focus addresses the development and testing of a sensory feedback system, based on the latest distributed sensing and stimulation techniques. To this end, the thesis is comprised of two introductory chapters that describe the state of art in the field, the objectives, and the used methodology and contributions; as well as six studies that tackled the development of human-machine interfaces
    • …
    corecore