13,763 research outputs found

    Low radiation dose in computed tomography: the role of iodine

    Get PDF
    Recent approaches to reducing radiation exposure during CT examinations typically utilize automated dose modulation strategies on the basis of lower tube voltage combined with iterative reconstruction and other dose-saving techniques. Less clearly appreciated is the potentially substantial role that iodinated contrast media (CM) can play in low-radiation-dose CT examinations. Herein we discuss the role of iodinated CM in low-radiation-dose examinations and describe approaches for the optimization of CM administration protocols to further reduce radiation dose and/or CM dose while maintaining image quality for accurate diagnosis. Similar to the higher iodine attenuation obtained at low-tube-voltage settings, high-iodine-signal protocols may permit radiation dose reduction by permitting a lowering of mAs while maintaining the signal-to-noise ratio. This is particularly feasible in first pass examinations where high iodine signal can be achieved by injecting iodine more rapidly. The combination of low kV and IR can also be used to reduce the iodine dose. Here, in optimum contrast injection protocols, the volume of CM administered rather than the iodine concentration should be reduced, since with high-iodine-concentration CM further reductions of iodine dose are achievable for modern first pass examinations. Moreover, higher concentrations of CM more readily allow reductions of both flow rate and volume, thereby improving the tolerability of contrast administration

    Immediate adverse reactions to intravenous iodinated contrast media in computed tomography

    Get PDF
    Pesquisa quantitativa, exploratório-descritiva, de caráter não experimental, com o objetivo de conhecer as reações adversas imediatas ao contraste iodado intravenoso em pacientes hospitalizados, submetidos a tomografia computadorizada num hospital-escola no Sul do Brasil. Durante o período de estudo, todas as reações adversas manifestaram-se na intensidade leve, com freqüência de 12,5% com o uso de contraste iodado iônico e 1% com contraste não iônico. Extravasamento do meio radiopaco ocorreu em 2,2% das injeções em veia periférica, não havendo complicações em nenhum dos casos. Os resultados encontram-se dentro dos limites citados na literatura internacional e sugere-se que os serviços de tomografia conheçam as próprias taxas de reações adversas ao contraste iodado e as condições em que elas ocorrem, a fim de obter evidências para a avaliação dos respectivos processos assistenciais.Investigación cuantitativa del tipo exploratorio-descriptivo, de carácter no experimental. El objetivo consistía en conocer las reacciones adversas inmediatas al contraste yodado intravenoso en pacientes internados, sometidos a tomografía computarizada en un hospital escuela del sur de Brasil. Durante el período del estudio, todas las reacciones adversas tuvieron intensidad leve y una frecuencia del 12,5% con la utilización del contraste yodado iónico, y 1% con contraste no iónico. La extravasación del contraste ocurrió en un 2,2% de las inyecciones en vena periférica, no ocasionando complicaciones en ninguno de los casos. Los índices evidenciados en el presente estudio se mantuvieron dentro de los límites que constan en la revisión de literatura y, entre las recomendaciones, se sugiere que los servicios de tomografía conozcan los propios índices de reacciones adversas al contraste yodado y las condiciones en que ocurren, con la finalidad de obtener evidencias para evaluación de los respectivos procesos asistenciales.This exploratory-descriptive, non-experimental quantitative research aimed to learn about immediate adverse reactions to intravenous iodinated contrast media in hospitalized patients submitted to computed tomography at a teaching hospital in the South of Brazil. During the study period, all adverse reactions showed mild intensity, at a frequency of 12.5% with ionic iodinated contrast media, and 1% with non-ionic contrast agent. The extravasation of contrast occurred in 2.2% of the injections in a peripheral vein without complications in any of the cases. The results are within the limits cited in international literature and suggest that tomography service professionals should know their own rates of adverse reactions to iodinated contrast agent, as well as the conditions in which they occur, in order to obtain evidence to evaluate the respective care delivery processes

    The choice of gadolinium-based contrast agents: a radiologist’s responsibility between pharmaceutical equivalence and bioethical issues

    Get PDF
    Contrast Agents (CA) are among the most commonly prescribed drugs worldwide, and are used, with a variety of techniques, to increase and intensify the differences between body tissues and to help radiologist make diagnoses in a fast and precise way. In recent decades, advancements in research have resulted in significant improvements in their composition, and have made them safer and better-tolerated by patients; this notwithstanding, although the currently available CA are generally considered to be safe, their use is not completely without risk. The use of CA faces the radiologist with economic considerations, bioethical dilemmas, and possible profiles of professional responsibility. In fact, to achieve the best results in diagnostic imaging, radiologists have to focus on making an appropriate choice of CA, in consideration of efficacy, safety and appropriateness. Moreover, besides by cost/benefit models widely introduced in health management, radiologists are also influenced by their responsibility of appropriate use for the various diagnostic tests and, finally, the choice of best CA to utilise for each individual patient. Thus, the dilemma of choosing between the best and the most cost-effective tests and procedures is occurring more frequently every day. Different variables, such as the patient, examinations, and technology available, can affect the choice of CA in terms of obtaining the highest diagnostic quality, minimum impact on higher-risk patients, and optimisation of used volumes and injection flow

    Ferumoxytol-enhanced magnetic resonance angiography for the assessment of potential kidney transplant recipients

    Get PDF
    Objectives: Traditional contrast-enhanced methods for scanning blood vessels using magnetic resonance imaging (MRI) or CT carry potential risks for patients with advanced kidney disease. Ferumoxytol is a superparamagnetic iron oxide nanoparticle preparation that has potential as an MRI contrast agent in assessing the vasculature. Methods: Twenty patients with advanced kidney disease requiring aorto-iliac vascular imaging as part of pre-operative kidney transplant candidacy assessment underwent ferumoxytol-enhanced magnetic resonance angiography (FeMRA) between December 2015 and August 2016. All scans were performed for clinical indications where standard imaging techniques were deemed potentially harmful or inconclusive. Image quality was evaluated for both arterial and venous compartments. Results: First-pass and steady-state FeMRA using incremental doses of up to 4 mg/kg body weight of ferumoxytol as intravenous contrast agent for vascular enhancement was performed. Good arterial and venous enhancements were achieved, and FeMRA was not limited by calcification in assessing the arterial lumen. The scans were diagnostic and all patients completed their studies without adverse events. Conclusions: Our preliminary experience supports the feasibility and utility of FeMRA for vascular imaging in patients with advanced kidney disease due for transplant listing, which has the advantages of obtaining both arteriography and venography using a single test without nephrotoxicity

    A study on adverse drug reactions to non-ionic contrast medium in an Indian population: a 1-year experience

    Get PDF
    Background: To the best of our understanding, very few studies focusing on the adverse drug reaction (ADR) profile of non-ionic contrast medium (NICM) has been carried out until date among the Indian population. Hence, this study was planned. We sincerely believe that the knowledge gathered from this study can improve safer usage of these agents among the patients of Indian origin. The objective was to evaluate the incidence and severity of ADRs of non-ionic radio contrast media (CM) used in tertiary care hospital in Eastern India.Methods: For the duration of 1-year from July 2011 to July 2012, we prospectively recorded all the ADRs associated with the administration of NICM (iohexol and ioversol) in 3708 patients of Indian origin undergoing computed tomography scan at the hospital. The average median age, weight, dose used; types of ADRs, concomitant medication, final diagnosis, reasons for use were recorded and analyzed with appropriate statistical tools. Causality assessment was performed using Naranjo scale.Results: Eleven of 3708 patients who received either ioversol or iohexol developed ADRs (i.e. 0.3% of patients). The most common ADR was rigor. The incidences of mild, moderate and severe reactions were 55%, 36% and 9%, respectively. Average median age, weight, and dose used were 35 years, 66 kg and 70 ml, respectively. All the ADRs were early (occurred within 1 hr of CM administration). Due to logical constraints, the follow-up of these patients was not possible and hence late ADRs were not captured. The common concomitant medication used was pantoprazole (63.63% of patients). The difference in the incidence of ADRs by age distribution (Group 1 - Iohexol, Group 2 - Ioversol) and weight distribution was not statistically significant (p=0.75 and p=0.18, respectively). Causality analysis revealed that all the ADRs were possible (Score of 4). Interestingly, the incidence of reactions was noted to be higher in patients with a history of gastro intestinal disorders (45.45%).Conclusions: This pilot study reveals that adverse reactions to NICM are rare and severe reactions are less common among the patients of Indian origin. However, a larger multicentric study across the country should be carried out to understand the safety profile of these CM better among the Indian population

    Safety of intravenous iodinated contrast medium injection in rabbits undergoing conscious computed tomography

    Get PDF
    BACKGROUND: Contrast media in CT is widely used in dogs and cats to provide superior tissue delineation and increase the diagnostic capabilities. These contrast‐enhanced imaging techniques are gaining popularity in rabbits; published studies reporting the safety of doing so are lacking. METHODS: This retrospective observational study aimed to determine the incidence of adverse events following the intravenous administration of iodinated non‐ionic contrast medium in 350 rabbits. The medical records of this subset of rabbits admitted between January 2009 and November 2018, that underwent CT examination and received intravenous contrast media, were evaluated. RESULTS: From the 350 rabbits, 342 rabbits were still alive 7 days after the scan. A total of eight rabbits died within 7 days of the scan, seven of which within the first 24 h. All deaths were presumed to be sequelae to the diseases they were being investigated for and not thought to be related to the administration of intravenous contrast medium. CONCLUSIONS: The results indicated that the use of intravenous non‐iodinated contrast medium was well tolerated and safe in rabbits undergoing conscious CT examination

    Assessment and reporting of adverse drug reactions to iopromide: a study of risk perception and pharmacovigilance

    Get PDF
    Tesis por compendio de publicaciones[EN]To achieve the thesis goals, two original articles were performed, the first to evaluate patients’ awareness of ADR risks and the Portuguese Pharmacovigilance System and the second to provide a retrospective analysis of ADR to iopromide in a Portuguese private unit of radiology. In addition, to reinforce the background of the thesis, two review articles were incorporated: a narrative review of the safety assessment of iopromide focusing on adverse events and a scoping review of all-round approaches to increase adverse drug reaction reporting. [ES]Para lograr los objetivos de la tesis, organizada en compendio de artículos, se realizaron dos artículos originales, uno para evaluar el conocimiento de los pacientes sobre los riesgos de RAM y el Sistema de Farmacovigilancia de Portugal y otro para proporcionar un análisis retrospectivo de RAM a iopromida en una unidad privada de radiología portuguesa. Además, para reforzar los antecedentes de la tesis, se agregaron dos artículos de revisión, uno que utiliza una revisión narrativa de la evaluación de la seguridad de la iopromida que se centra en los eventos adversos y una revisión de alcance de enfoques integrales para aumentar la notificación de reacciones adversas a medicamentos

    ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group

    Get PDF
    The use of contrast media for cardiac imaging becomes increasing as the widespread of cardiac CT and cardiac MR. A radiologist needs to carefully consider the indication and the injection protocol of contrast media to be used as well as the possibility of adverse effect. There are several guidelines for contrast media in western countries. However, these are focusing the adverse effect of contrast media. The Asian Society of Cardiovascular Imaging, the only society dedicated to cardiovascular imaging in Asia, formed a Working Group and created a guideline, which summarizes the integrated knowledge of contrast media for cardiac imaging. In cardiac imaging, coronary artery evaluation is feasible by non-contrast MR angiography, which can be an alternative examination in high risk patients for the use of iodine contrast media. Furthermore, the body habitus of Asian patients is usually smaller than that of their western counterparts. This necessitates modifications in the injection protocol and in the formula for calculation of estimated glomerular filtration rate. This guideline provided fundamental information for the use of contrast media for Asian patients in cardiac imaging

    Intravascular Iodinated Contrast Media Administration in Adults: A Patient Safety Approach

    Get PDF
    In 2013, The ICPS Contrast Media Usage and Exposure Workgroup was formed to review, define, assess and implement best practices regarding the use of intravascular iodinated contrast media (CM) in diagnostic and interventional procedures with respect to the associated risk of contrast media - induced nephropathy (CIN) and other adverse events. The interdisciplinary workgroup consisted of radiologists, cardiologists, nephrologists, nurses, technologists, pharmacists and patient safety experts. The workgroup met regularly to review published best practices and current practices within each member health-system. The workgroup focused on opportunities to improve patient safety within rep resent health-systems and emphasized consensus-based recommendations aimed at reducing intra-institutional variability. Based on current literature, best practices, and professional experience, the workgroup created these recommendations for safe use of intravenous iodinated contrast media. These recommendations do not replace sound clinical judgment or other published guidelines
    corecore