1,267 research outputs found

    Monte Carlo-based Noise Compensation in Coil Intensity Corrected Endorectal MRI

    Get PDF
    Background: Prostate cancer is one of the most common forms of cancer found in males making early diagnosis important. Magnetic resonance imaging (MRI) has been useful in visualizing and localizing tumor candidates and with the use of endorectal coils (ERC), the signal-to-noise ratio (SNR) can be improved. The coils introduce intensity inhomogeneities and the surface coil intensity correction built into MRI scanners is used to reduce these inhomogeneities. However, the correction typically performed at the MRI scanner level leads to noise amplification and noise level variations. Methods: In this study, we introduce a new Monte Carlo-based noise compensation approach for coil intensity corrected endorectal MRI which allows for effective noise compensation and preservation of details within the prostate. The approach accounts for the ERC SNR profile via a spatially-adaptive noise model for correcting non-stationary noise variations. Such a method is useful particularly for improving the image quality of coil intensity corrected endorectal MRI data performed at the MRI scanner level and when the original raw data is not available. Results: SNR and contrast-to-noise ratio (CNR) analysis in patient experiments demonstrate an average improvement of 11.7 dB and 11.2 dB respectively over uncorrected endorectal MRI, and provides strong performance when compared to existing approaches. Conclusions: A new noise compensation method was developed for the purpose of improving the quality of coil intensity corrected endorectal MRI data performed at the MRI scanner level. We illustrate that promising noise compensation performance can be achieved for the proposed approach, which is particularly important for processing coil intensity corrected endorectal MRI data performed at the MRI scanner level and when the original raw data is not available.Comment: 23 page

    Inhomogeneity Correction in High Field Magnetic Resonance Images

    Get PDF
    Projecte realitzat en col.laboració amb el centre Swiss Federal Institute of Technology (EPFL)Magnetic Resonance Imaging, MRI, is one of the most powerful and harmless ways to study human inner tissues. It gives the chance of having an accurate insight into the physiological condition of the human body, and specially, the brain. Following this aim, in the last decade MRI has moved to ever higher magnetic field strength that allow us to get advantage of a better signal-to-noise ratio. This improvement of the SNR, which increases almost linearly with the field strength, has several advantages: higher spatial resolution and/or faster imaging, greater spectral dispersion, as well as an enhanced sensitivity to magnetic susceptibility. However, at high magnetic resonance imaging, the interactions between the RF pulse and the high permittivity samples, which causes the so called Intensity Inhomogeneity or B1 inhomogeneity, can no longer be negligible. This inhomogeneity causes undesired efects that afects quantitatively image analysis and avoid the application classical intensity-based segmentation and other medical functions. In this Master thesis, a new method for Intensity Inhomogeneity correction at high ¯eld is presented. At high ¯eld is not possible to achieve the estimation and the correction directly from the corrupted data. Thus, this method attempt the correction by acquiring extra information during the image process, the RF map. The method estimates the inhomogeneity by the comparison of both acquisitions. The results are compared to other methods, the PABIC and the Low-Pass Filter which try to correct the inhomogeneity directly from the corrupted data

    Respiratory organ motion in interventional MRI : tracking, guiding and modeling

    Get PDF
    Respiratory organ motion is one of the major challenges in interventional MRI, particularly in interventions with therapeutic ultrasound in the abdominal region. High-intensity focused ultrasound found an application in interventional MRI for noninvasive treatments of different abnormalities. In order to guide surgical and treatment interventions, organ motion imaging and modeling is commonly required before a treatment start. Accurate tracking of organ motion during various interventional MRI procedures is prerequisite for a successful outcome and safe therapy. In this thesis, an attempt has been made to develop approaches using focused ultrasound which could be used in future clinically for the treatment of abdominal organs, such as the liver and the kidney. Two distinct methods have been presented with its ex vivo and in vivo treatment results. In the first method, an MR-based pencil-beam navigator has been used to track organ motion and provide the motion information for acoustic focal point steering, while in the second approach a hybrid imaging using both ultrasound and magnetic resonance imaging was combined for advanced guiding capabilities. Organ motion modeling and four-dimensional imaging of organ motion is increasingly required before the surgical interventions. However, due to the current safety limitations and hardware restrictions, the MR acquisition of a time-resolved sequence of volumetric images is not possible with high temporal and spatial resolution. A novel multislice acquisition scheme that is based on a two-dimensional navigator, instead of a commonly used pencil-beam navigator, was devised to acquire the data slices and the corresponding navigator simultaneously using a CAIPIRINHA parallel imaging method. The acquisition duration for four-dimensional dataset sampling is reduced compared to the existing approaches, while the image contrast and quality are improved as well. Tracking respiratory organ motion is required in interventional procedures and during MR imaging of moving organs. An MR-based navigator is commonly used, however, it is usually associated with image artifacts, such as signal voids. Spectrally selective navigators can come in handy in cases where the imaging organ is surrounding with an adipose tissue, because it can provide an indirect measure of organ motion. A novel spectrally selective navigator based on a crossed-pair navigator has been developed. Experiments show the advantages of the application of this novel navigator for the volumetric imaging of the liver in vivo, where this navigator was used to gate the gradient-recalled echo sequence

    Double volumetric navigators for real-time simultaneous shim and motion measurement and correction in Glycogen Chemical Exchange Saturation Transfer (GlycoCEST) MRI

    Get PDF
    Glycogen is the primary glucose storage mechanism in in living systems and plays a central role in systemic glucose homeostasis. The study of muscle glycogen concentrations in vivo still largely relies on tissue sampling methods via needle biopsy. However, muscle biopsies are invasive and limit the frequency of measurements and the number of sites that can be assessed. Non-invasive methods for quantifying glycogen in vivo are therefore desirable in order to understand the pathophysiology of common diseases with dysregulated glycogen metabolism such as obesity, insulin resistance, and diabetes, as well as glycogen metabolism in sports physiology. Chemical Exchange Saturation Transfer (CEST) MRI has emerged as a non-invasive contrast enhancement technique that enables detection of molecules, like glycogen, whose concentrations are too low to impact the contrast of standard MR imaging. CEST imaging is performed by selectively saturating hydrogen nuclei of the metabolites that are in chemical exchange with those of water molecules and detecting a reduction in MRI signal in the water pool resulting from continuous chemical exchange. However, CEST signal can easily be compromised by artifacts. Since CEST is based on chemical shift, it is very sensitive to field inhomogeneity which may arise from poor initial shimming, subject respiration, heating of shim iron, mechanical vibrations or subject motion. This is a particular problem for molecules that resonate close to water, such as - OH protons in glycogen, where small variations in chemical shift cause misinterpretation of CEST data. The purpose of this thesis was to optimize the CEST MRI sequence for glycogen detection and implement a real-time simultaneous motion and shim correction and measurement method. First, analytical solution of the Bloch-McConnell equations was used to find optimal continuous wave RF pulse parameters for glycogen detection, and results were validated on a phantom with varying glycogen concentrations and in vivo on human calf muscle. Next, the CEST sequence was modified with double volumetric navigators (DvNavs) to measure pose changes and update field of view and zero- and first-order shim parameters. Finally, the impact of B0 field fluctuations on the scan-rescan reproducibility of CEST was evaluated in vivo in 9 volunteers across 10 different scans. Simulation results showed an optimal RF saturation power of 1.5µT and duration of 1s for glycoCEST. These parameters were validated experimentally in vivo and the ability to detect varying glycogen concentrations was demonstrated in a phantom. Phantom data showed that the DvNav-CEST sequence accurately estimates system frequency and linear shim gradient changes due to motion and corrects resulting image distortions. In addition, DvNav-CEST was shown to yield improved CEST quantification in vivo in the presence of motion and motion-induced field inhomogeneity. B0 field fluctuations were found to lower the reproducibility of CEST measures: the mean coefficient of variation (CoV) for repeated scans was 83.70 ± 70.79 % without shim correction. However, the DvNav-CEST sequence was able to measure and correct B0 variations, reducing the CoV to 2.6 ± 1.37 %. The study confirms the possibility of detecting glycogen using CEST MRI at 3 T and shows the potential of the real-time shim and motion navigated CEST sequence for producing repeatable results in vivo by reducing the effect of B0 field fluctuations

    Doctor of Philosophy

    Get PDF
    dissertationThe gold standard for evaluation of arterial disease using MR continues to be contrast-enhanced MR angiography (MRA) with gadolinium-based contrast agents (Gd-MRA). There has been a recent resurgence in interest in methods that do not rely on gadolinium for enhancement of blood vessels due to associations Gd-MRA has with nephrogenic systemic fibrosis (NSF) in patients with impaired renal function. The risk due to NSF has been shown to be minimized when selecting the appropriate contrast type and dose. Even though the risk of NSF has been shown to be minimized, demand for noncontrast MRA has continued to rise to reduce examination cost, and improve patient comfort and ability to repeat scans. Several methods have been proposed and used to perform angiography of the aorta and peripheral arteries without the use of gadolinium. These techniques have had limitations in transmit radiofrequency field (B1+) inhomogeneities, acquisition time, and specific hardware requirements, which have stunted the utility of noncontrast enhanced MRA. In this work feasibility of noncontrast (NC) MRA at 3T of the femoral arteries using dielectric padding, and using 3D radial stack of stars and compressed sensing to accelerate acquisitions in the abdomen and thorax were tested. Imaging was performed on 13 subjects in the pelvis and thighs using high permittivity padding, and 11 in the abdomen and 19 in the thorax using 3D radial stack of stars with tiny golden angle using gold standards or previously published techniques. Qualitative scores for each study were determined by radiologists who were blinded to acquisition type. Vessel conspicuity in the thigh and pelvis showed significant increase when high permittivity padding was used in the acquisition. No significant difference in image quality was observed in the abdomen and thorax when using undersampling, except for the descending aorta in thoracic imaging. All image quality scores were determined to be of diagnostic quality. In this work it is shown that NC-MRA can be improved through the use of high permittivity dielectric padding and acquisition time can be decreased through the use of 3D radial stack of stars acquisitions

    Real-time motion and retrospective coil sensitivity correction for CEST using volumetric navigators (vNavs) at 7T

    Get PDF
    Purpose To explore the impact of temporal motion-induced coil sensitivity changes on CEST-MRI at 7T and its correction using interleaved volumetric EPI navigators, which are applied for real-time motion correction. Methods Five healthy volunteers were scanned via CEST. A 4-fold correction pipeline allowed the mitigation of (1) motion, (2) motion-induced coil sensitivity variations, Delta B1-, (3) motion-induced static magnetic field inhomogeneities, Delta B-0, and (4) spatially varying transmit RF field fluctuations, Delta B1+. Four CEST measurements were performed per session. For the first 2, motion correction was turned OFF and then ON in absence of voluntary motion, whereas in the other 2 controlled head rotations were performed. During post-processing Delta B1- was removed additionally for the motion-corrected cases, resulting in a total of 6 scenarios to be compared. In all cases, retrospective increment B-0 and -Delta B1+ corrections were performed to compute artifact-free magnetization transfer ratio maps with asymmetric analysis (MTRasym). Results Dynamic Delta B1- correction successfully mitigated signal deviations caused by head motion. In 2 frontal lobe regions of volunteer 4, induced relative signal errors of 10.9% and 3.9% were reduced to 1.1% and 1.0% after correction. In the right frontal lobe, the motion-corrected MTRasym contrast deviated 0.92%, 1.21%, and 2.97% relative to the static case for Delta omega = 1, 2, 3 +/- 0.25 ppm. The additional application of Delta B1- correction reduced these deviations to 0.10%, 0.14%, and 0.42%. The fully corrected MTRasym values were highly consistent between measurements with and without intended head rotations. Conclusion Temporal Delta B1- cause significant CEST quantification bias. The presented correction pipeline including the proposed retrospective Delta B1- correction significantly reduced motion-related artifacts on CEST-MRI.Peer reviewe

    Real‐time motion and retrospective coil sensitivity correction for CEST using volumetric navigators (vNavs) at 7T

    Get PDF
    PURPOSE: To explore the impact of temporal motion-induced coil sensitivity changes on CEST-MRI at 7T and its correction using interleaved volumetric EPI navigators, which are applied for real-time motion correction. METHODS: Five healthy volunteers were scanned via CEST. A 4-fold correction pipeline allowed the mitigation of (1) motion, (2) motion-induced coil sensitivity variations, Δ B 1 - , (3) motion-induced static magnetic field inhomogeneities, ΔB0 , and (4) spatially varying transmit RF field fluctuations, ΔB 1 + . Four CEST measurements were performed per session. For the first 2, motion correction was turned OFF and then ON in absence of voluntary motion, whereas in the other 2 controlled head rotations were performed. During post-processing Δ B 1 - was removed additionally for the motion-corrected cases, resulting in a total of 6 scenarios to be compared. In all cases, retrospective ∆B0 and - ΔB 1 + corrections were performed to compute artifact-free magnetization transfer ratio maps with asymmetric analysis (MTRasym ). RESULTS: Dynamic Δ B 1 - correction successfully mitigated signal deviations caused by head motion. In 2 frontal lobe regions of volunteer 4, induced relative signal errors of 10.9% and 3.9% were reduced to 1.1% and 1.0% after correction. In the right frontal lobe, the motion-corrected MTRasym contrast deviated 0.92%, 1.21%, and 2.97% relative to the static case for Δω = 1, 2, 3 ± 0.25 ppm. The additional application of Δ B 1 - correction reduced these deviations to 0.10%, 0.14%, and 0.42%. The fully corrected MTRasym values were highly consistent between measurements with and without intended head rotations. CONCLUSION: Temporal Δ B 1 - cause significant CEST quantification bias. The presented correction pipeline including the proposed retrospective Δ B 1 - correction significantly reduced motion-related artifacts on CEST-MRI

    MR-based protein imaging of the human brain by means of dualCEST

    Get PDF
    Chemical exchange saturation transfer (CEST) is an emerging magnetic resonance imaging (MRI) technique enabling indirect detection of low-concentration cellular compounds in living tissue by their magnetization transfer with water. In particular, protein-attributed CEST signals have been shown to provide valuable diagnostic information for various diseases. While conventional CEST approaches suffer from confounding signals from metabolites and macromolecules, the novel dual-frequency irradiation CEST (dualCEST) technique enables increased protein specificity by selectively detecting the intramolecular spin-diffusion. However, application of this technique has so far been limited to spectroscopic investigations of model solutions at ultrahigh magnetic field strengths. In this thesis, dualCEST was translated to a clinical whole-body MR scanner, enabling protein imaging of the human brain. To this end, several methodological developments were implemented and optimized: (i) improved dual-frequency pulses for signal preparation, (ii) a fast and robust volumetric image readout, (iii) a weighted acquisition scheme, and (iv) an adaptive denoising technique. The resulting improvements are not limited to dualCEST but are relevant for the research field of CEST-MRI in general. Extensive measurements of biochemical model solutions and volunteers demonstrated the protein specificity and reproducibility of dualCEST-MRI. The clinical applicability was verified in pilot studies with tumor and Alzheimer’s patients