2,775 research outputs found
Resolution Properties in Regularized Dynamic MRI Reconstruction
In dynamic MRI, one is constantly addressing the tradeoff between spatial and temporal resolution. Regularized reconstruction methods may offer benefits in terms of this tradeoff. However, selection of the regularization parameters is challenging. In this work we examine the spatial and temporal resolution of penalized-likelihood image reconstruction for dynamic MRI, and present an accelerated method for computing the local impulse response. This method may prove advantageous for regularization parameter selection.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85877/1/Fessler228.pd
Accelerated High-Resolution Photoacoustic Tomography via Compressed Sensing
Current 3D photoacoustic tomography (PAT) systems offer either high image
quality or high frame rates but are not able to deliver high spatial and
temporal resolution simultaneously, which limits their ability to image dynamic
processes in living tissue. A particular example is the planar Fabry-Perot (FP)
scanner, which yields high-resolution images but takes several minutes to
sequentially map the photoacoustic field on the sensor plane, point-by-point.
However, as the spatio-temporal complexity of many absorbing tissue structures
is rather low, the data recorded in such a conventional, regularly sampled
fashion is often highly redundant. We demonstrate that combining variational
image reconstruction methods using spatial sparsity constraints with the
development of novel PAT acquisition systems capable of sub-sampling the
acoustic wave field can dramatically increase the acquisition speed while
maintaining a good spatial resolution: First, we describe and model two general
spatial sub-sampling schemes. Then, we discuss how to implement them using the
FP scanner and demonstrate the potential of these novel compressed sensing PAT
devices through simulated data from a realistic numerical phantom and through
measured data from a dynamic experimental phantom as well as from in-vivo
experiments. Our results show that images with good spatial resolution and
contrast can be obtained from highly sub-sampled PAT data if variational image
reconstruction methods that describe the tissues structures with suitable
sparsity-constraints are used. In particular, we examine the use of total
variation regularization enhanced by Bregman iterations. These novel
reconstruction strategies offer new opportunities to dramatically increase the
acquisition speed of PAT scanners that employ point-by-point sequential
scanning as well as reducing the channel count of parallelized schemes that use
detector arrays.Comment: submitted to "Physics in Medicine and Biology
Spherical deconvolution of multichannel diffusion MRI data with non-Gaussian noise models and spatial regularization
Spherical deconvolution (SD) methods are widely used to estimate the
intra-voxel white-matter fiber orientations from diffusion MRI data. However,
while some of these methods assume a zero-mean Gaussian distribution for the
underlying noise, its real distribution is known to be non-Gaussian and to
depend on the methodology used to combine multichannel signals. Indeed, the two
prevailing methods for multichannel signal combination lead to Rician and
noncentral Chi noise distributions. Here we develop a Robust and Unbiased
Model-BAsed Spherical Deconvolution (RUMBA-SD) technique, intended to deal with
realistic MRI noise, based on a Richardson-Lucy (RL) algorithm adapted to
Rician and noncentral Chi likelihood models. To quantify the benefits of using
proper noise models, RUMBA-SD was compared with dRL-SD, a well-established
method based on the RL algorithm for Gaussian noise. Another aim of the study
was to quantify the impact of including a total variation (TV) spatial
regularization term in the estimation framework. To do this, we developed TV
spatially-regularized versions of both RUMBA-SD and dRL-SD algorithms. The
evaluation was performed by comparing various quality metrics on 132
three-dimensional synthetic phantoms involving different inter-fiber angles and
volume fractions, which were contaminated with noise mimicking patterns
generated by data processing in multichannel scanners. The results demonstrate
that the inclusion of proper likelihood models leads to an increased ability to
resolve fiber crossings with smaller inter-fiber angles and to better detect
non-dominant fibers. The inclusion of TV regularization dramatically improved
the resolution power of both techniques. The above findings were also verified
in brain data
Feasibility of automated 3-dimensional magnetic resonance imaging pancreas segmentation.
PurposeWith the advent of MR guided radiotherapy, internal organ motion can be imaged simultaneously during treatment. In this study, we evaluate the feasibility of pancreas MRI segmentation using state-of-the-art segmentation methods.Methods and materialT2 weighted HASTE and T1 weighted VIBE images were acquired on 3 patients and 2 healthy volunteers for a total of 12 imaging volumes. A novel dictionary learning (DL) method was used to segment the pancreas and compared to t mean-shift merging (MSM), distance regularized level set (DRLS), graph cuts (GC) and the segmentation results were compared to manual contours using Dice's index (DI), Hausdorff distance and shift of the-center-of-the-organ (SHIFT).ResultsAll VIBE images were successfully segmented by at least one of the auto-segmentation method with DI >0.83 and SHIFT ≤2 mm using the best automated segmentation method. The automated segmentation error of HASTE images was significantly greater. DL is statistically superior to the other methods in Dice's overlapping index. For the Hausdorff distance and SHIFT measurement, DRLS and DL performed slightly superior to the GC method, and substantially superior to MSM. DL required least human supervision and was faster to compute.ConclusionOur study demonstrated potential feasibility of automated segmentation of the pancreas on MRI images with minimal human supervision at the beginning of imaging acquisition. The achieved accuracy is promising for organ localization
- …