79 research outputs found

    Design and fabrication of a modularized humanoid arm with pneumatic artificial muscles

    Get PDF
    Capstone Project submitted to the Department of Engineering, Ashesi University in partial fulfillment of the requirements for the award of Bachelor of Science degree in Mechanical Engineering, May 2021With increase investment in the development of humanoids, there offers a window of opportunity to leverage the rapidly growing market of soft robotics in our strides towards more accurate biomimetic motion and study of humanoids and their applicatory areas. This project encompasses the systematic design, implementation and testing of a lightweight low-cost humanoid arm that utilizes Pneumatic Artificial Muscles (PAM). These muscles do not only exhibit twistable and bendable human-like muscle contractions but modularized in design to stand as a complete controllable unit which may be dissociated and mountable on a support frame on its own. This project achieves the design of a mobile arm unit with total weight of less than 2kg of which is distributed with one-third the weight being borne on the arm. The realized powerto- weight ratio of near 5W per kilogram, under an approximate 13.5 litre per minute rate of pressurization is of desired muscle force, and flex speeds. The McKibben tubing choice of PAM is experimentally validated under a linear fit for its force-contraction performance. This design makes considerable strides in cutting down weight, leveraging power, and being much cheaper than existing solutions. Comparable lightweight arm designs of which some are commercially available have weights of 38kg (Mitsubishi PA10arm), 14kg (KUKA lightweight arm), etc., with power-to-weight ratios of near 1W/kg. However, this project designs cuts down these weights drastically to about 2kg (without any sensory unit yet) and more than doubles the power to weight ratios mentioned.Ashesi Universit

    Toward Standardizing the Classification of Robotic Gait Rehabilitation Systems

    Get PDF

    Hierarchical Compliance Control of a Soft Ankle Rehabilitation Robot Actuated by Pneumatic Muscles

    Get PDF
    Traditional compliance control of a rehabilitation robot is implemented in task space by using impedance or admittance control algorithms. The soft robot actuated by pneumatic muscle actuators (PMAs) is becoming prominent for patients as it enables the compliance being adjusted in each active link, which, however, has not been reported in the literature. This paper proposes a new compliance control method of a soft ankle rehabilitation robot that is driven by four PMAs configured in parallel to enable three degrees of freedom movement of the ankle joint. A new hierarchical compliance control structure, including a low-level compliance adjustment controller in joint space and a high-level admittance controller in task space, is designed. An adaptive compliance control paradigm is further developed by taking into account patient’s active contribution and movement ability during a previous period of time, in order to provide robot assistance only when it is necessarily required. Experiments on healthy and impaired human subjects were conducted to verify the adaptive hierarchical compliance control scheme. The results show that the robot hierarchical compliance can be online adjusted according to the participant’s assessment. The robot reduces its assistance output when participants contribute more and vice versa, thus providing a potentially feasible solution to the patient-in-loop cooperative training strateg

    Feasibility Analysis of a Powered Lower-Limb Orthotic for the Mobility Impaired User

    Get PDF
    Powered orthotic devices can be used to restore mobility to the impaired user, and may thereby assist them in daily living tasks. An investigation is performed herein to examine the feasibility of a powered lower-limb orthotic in assisting the sit-to-stand task by 50% of the required torque. Feasibility is considered via simulation. A three-link sit-to-stand model, which is driven by kinematic data, is developed. Models of a Pneumatic Muscle Actuator and a DC motor are used to determine which of the two technologies can make a more appropriate contribution to the sit-to-stand task. Simulation revealed that both the Pneumatic Muscle Actuator and the DC motor are reasonable actuator choices, and neither limited the ability to achieve 50% torque assistance. The ability to assist the task was, however, limited by the ability to derive a control signal for the actuator from the user-orthotic interface. It was concluded that the user-orthotic interface requires further investigation. It was also found that while both actuator technologies are suitable for contributing 50% of the required torque, the Pneumatic Muscle Actuator is preferable due to its ability to scale to greater torques

    Wearable exoskeleton systems based-on pneumatic soft actuators and controlled by parallel processing

    Get PDF
    Human assistance innovation is essential in an increasingly aging society and one technology that may be applicable is exoskeletons. However, traditional rigid exoskeletons have many drawbacks. This research includes the design and implementation of upper-limb power assist and rehabilitation exoskeletons based on pneumatic soft actuators. A novel extensor-contractor pneumatic muscle has been designed and constructed. This new actuator has bidirectional action, allowing it to both extend and contract, as well as create force in both directions. A mathematical model has been developed for the new novel actuator which depicts the output force of the actuator. Another new design has been used to create a novel bending pneumatic muscle, based on an extending McKibben muscle and modelled mathematically according to its geometric parameters. This novel bending muscle design has been used to create two versions of power augmentation gloves. These exoskeletons are controlled by adaptive controllers using human intention. For finger rehabilitation a glove has been developed to bend the fingers (full bending) by using our novel bending muscles. Inspired by the zero position (straight fingers) problem for post-stroke patients, a new controllable stiffness bending actuator has been developed with a novel prototype. To control this new rehabilitation exoskeleton, online and offline controller systems have been designed for the hand exoskeleton and the results have been assessed experimentally. Another new design of variable stiffness actuator, which controls the bending segment, has been developed to create a new version of hand exoskeletons in order to achieve more rehabilitation movements in the same single glove. For Forearm rehabilitation, a rehabilitation exoskeleton has been developed for pronation and supination movements by using the novel extensor-contractor pneumatic muscle. For the Elbow rehabilitation an elbow rehabilitation exoskeleton was designed which relies on novel two-directional bending actuators with online and offline feedback controllers. Lastly for upper-limb joint is the wrist, we designed a novel all-directional bending actuator by using the moulding bladder to develop the wrist rehabilitation exoskeleton by a single all-directional bending muscle. Finally, a totally portable, power assistive and rehabilitative prototype has been developed using a parallel processing intelligent control chip

    Advances in Robotics, Automation and Control

    Get PDF
    The book presents an excellent overview of the recent developments in the different areas of Robotics, Automation and Control. Through its 24 chapters, this book presents topics related to control and robot design; it also introduces new mathematical tools and techniques devoted to improve the system modeling and control. An important point is the use of rational agents and heuristic techniques to cope with the computational complexity required for controlling complex systems. Through this book, we also find navigation and vision algorithms, automatic handwritten comprehension and speech recognition systems that will be included in the next generation of productive systems developed by man

    Adaptive control for wearable robots in human-centered rehabilitation tasks

    Get PDF
    Robotic rehabilitation therapies have been improving by providing the needed assistance to the patient, in a human-centered environment, and also helping the therapist to choose the necessary procedure. This thesis presents an adaptive "Assistance-as-needed" strategy which adheres to the specific needs of the patient and with the inputs from the therapist, whenever needed. The exertion of assistive and responsive behavior of the lower limb wearable robot is dedicated for the rehabilitation of incomplete spinal cord injury (SCI) patients. The main objective is to propose and evaluate an adaptive control model on a wearable robot, assisting the user and adhering to their needs, with no or less combination of external devices. The adaptation must be more interactive to understand the user needs and their volitional orders. Similarly, by using the existing muscular strength, in incomplete SCI patients, as a motivation to pursue the movement and assist them, only when needed. The adaptive behavior of the wearable robot is proposed by monitoring the interaction and movement of the user. This adaptation is achieved by modulating the stiffness of the exoskeleton in function of joint parameters, such as positions and interaction torques. These joint parameters are measured from the user independently and then used to update the new stiffness value. The adaptive algorithm performs with no need of external sensors, making it simple in terms of usage. In terms of rehabilitation, it is also desirable to be compatible with combination of assistive devices such as muscle stimulation, neural activity (BMI) and body balance (Wii), to deliver a user friendly and effective therapy. Combination of two control approaches has been employed, to improve the efficiency of the adaptive control model and was evaluated using a wearable lower limb exoskeleton device, H1. The control approaches, Hierarchical and Task based approach have been used to assist the patient as needed and simultaneously motivate the patient to pursue the therapy. Hierarchical approach facilitates combination of multiple devices to deliver an effective therapy by categorizing the control architecture in two layers, Low level and High level control. Task-based approaches engage in each task individually and allow the possibility to combine them at any point of time. It is also necessary to provide an interaction based approach to ensure the complete involvement of the user and for an effective therapy. By means of this dissertation, a task based adaptive control is proposed, in function of human-orthosis interaction, which is applied on a hierarchical control scheme. This control scheme is employed in a wearable robot, with the intention to be applied or accommodated to different pathologies, with its adaptive capabilities. The adaptive control model for gait assistance provides a comprehensive solution through a single implementation: Adaptation inside a gait cycle, continuous support through gait training and in real time. The performance of this control model has been evaluated with healthy subjects, as a preliminary study, and with paraplegic patients. Results of the healthy subjects showed a significant change in the pattern of the interaction torques, elucidating a change in the effort and adaptation to the user movement. In case of patients, the adaptation showed a significant improvement in the joint performance (flexion/extension range) and change in interaction torques. The change in interaction torques (positive to negative) reflects the active participation of the patient, which also explained the adaptive performance. The patients also reported that the movement of the exoskeleton is flexible and the walking patterns were similar to their own distinct patterns. The presented work is performed as part of the project HYPER, funded by Ministerio de Ciencia y Innovación, Spain. (CSD2009 - 00067 CONSOLIDER INGENIOLas terapias de rehabilitación robóticas han sido mejoradas gracias a la inclusión de la asistencia bajo demanda, adaptada a las variaciones de las necesidades del paciente, así como a la inclusión de la ayuda al terapeuta en la elección del procedimiento necesario. Esta tesis presenta una estrategia adaptativa de asistencia bajo demanda, la cual se ajusta a las necesidades específicas del paciente junto a las aportaciones del terapeuta siempre que sea necesario. El esfuerzo del comportamiento asistencial y receptivo del robot personal portátil para extremidades inferiores está dedicado a la rehabilitación de pacientes con lesión de la médula espinal (LME) incompleta. El objetivo principal es proponer y evaluar un modelo de control adaptativo en un robot portátil, ayudando al usuario y cumpliendo con sus necesidades, en ausencia o con reducción de dispositivos externos. La adaptación debe ser más interactiva para entender las necesidades del usuario y sus intenciones u órdenes volitivas. De modo similar, usando la fuerza muscular existente (en pacientes con LME incompleta) como motivación para lograr el movimiento y asistirles solo cuando sea necesario. El comportamiento adaptativo del robot portátil se propone mediante la monitorización de la interacción y movimiento del usuario. Esta adaptación conjunta se consigue modulando la rigidez en función de los parámetros de la articulación, tales como posiciones y pares de torsión. Dichos parámetros se miden del usuario de forma independiente y posteriormente se usan para actualizar el nuevo valor de la rigidez. El desempeño del algoritmo adaptativo no requiere de sensores externos, lo que favorece la simplicidad de su uso. Para una adecuada rehabilitación, efectiva y accesible para el usuario, es necesaria la compatibilidad con diversos mecanismos de asistencia tales como estimulación muscular, actividad neuronal y equilibrio corporal. Para mejorar la eficiencia del modelo de control adaptativo se ha empleado una combinación de dos enfoques de control, y para su evaluación se ha utilizado un exoesqueleto robótico H1. Los enfoques de control Jerárquico y de Tarea se han utilizado para ayudar al usuario según sea necesario, y al mismo tiempo motivarle para continuar el tratamiento. Enfoque jerárquico facilita la combinación de múltiples dispositivos para ofrecer un tratamiento eficaz mediante la categorización de la arquitectura de control en dos niveles : el control de bajo nivel y de alto nivel. Los enfoques basados en tareas involucran a la persona en cada tarea individual, y ofrecen la posibilidad de combinarlas en cualquier momento. También es necesario proporcionar un enfoque basado en la interacción con el usuario, para asegurar su participación y lograr así una terapia eficaz. Mediante esta tesis, proponemos un control adaptativo basado en tareas y en función de la interacción persona-ortesis, que se aplica en un esquema de control jerárquico. Este esquema de control se emplea en un robot portátil, con la intención de ser aplicado o acomodado a diferentes patologías, con sus capacidades de adaptación. El modelo de control adaptativo propuesto proporciona una solución integral a través de una única aplicación: adaptación dentro de la marcha y apoyo continúo a través de ejercicios de movilidad en tiempo real. El rendimiento del modelo se ha evaluado en sujetos sanos según un estudio preliminar, y posteriormente también en pacientes parapléjicos. Los resultados en sujetos sanos mostraron un cambio significativo en el patrón de los pares de interacción, elucidando un cambio en la energía y la adaptación al movimiento del usuario. En el caso de los pacientes, la adaptación mostró una mejora significativa en la actuación conjunta (rango de flexión / extensión) y el cambio en pares de interacción. El cambio activo en pares de interacción (positivo a negativo) refleja la participación activa del paciente, lo que también explica el comportamiento adaptativo

    Nonlinear robust control of functional electrical stimulation system for paraplegia

    Get PDF
    The study was directed towards enhancing Functional Electrical Stimulation (FES) for sit-to-stand movement restoration in paraplegia subjects. The scarcity of FES assistive devices was due to the inability of the developed equipment to attain clinical acceptance. Applications of control systems have shown fruitful results. And based on the literature, further improvements in model, trajectory and control systems are needed. Model with a higher level of accuracy and continuous as well as bump-free trajectories are essential ingredients for better control systems. The control systems can be enhanced by giving considering to changes in mass of the subject, disturbance rejection and stability. Hence, the comprehensive control scheme is necessary for this application as well as a better model and trajectory. In modelling an additional joint has been considered to improve the accuracy. In trajectory planning, the six-order polynomial has been used to refine the desired trajectory. The comprehensive control systems have been designed with consideration of robustness, disturbance rejection, and stability. Three nonlinear control approaches have been investigated; the Sliding Mode Control (SMC), Feedback Linearisation Control (FLC), and Back-Stepping Control (BSC). Results reveal improvements in the accuracy of the kinematic model by 24%, and the dynamic model by 47%. The trajectory planning parameters are continuous, and not susceptible to jerks or spikes. Execution time enhanced by 11%, the upper and lower terminal velocities improved by 16.9% and 20.9% respectively. The system response without disturbance shows good results with the SMC, FLC, and BSC. Revelations by robustness examination also maintain remarkable enhancements in the parameters with both 53% and 126% mass. The results for disturbance rejection examinations with fatigue, spasm, tremor, and combined disturbance effects showed sustenance of refinement in the response parameters. Therefore, indicating improvements despite the changes to the system. The BSC showed the best performance, followed by the FLC, and the SMC. Hence, the BSC is recommended for such systems

    High-efficiency sma-based actuator

    Get PDF
    Design proposal and implementation analysis of an alternative high displacement flexible SMA-based actuator topology, targeting improved energy efficiency and actuation time, by completely overhaulingSMAwire’s surrounding conditions, specifically adding high heat capacity fluids and improving thermal management.Ingeniería Electrónica Industrial y Automátic
    corecore