5,665 research outputs found

    Development of real-time cellular impedance analysis system

    Get PDF
    The cell impedance analysis technique is a label-free, non-invasive method, which simplifies sample preparation and allows applications requiring unmodified cell retrieval. However, traditional impedance measurement methods suffer from various problems (speed, bandwidth, accuracy) for extracting the cellular impedance information. This thesis proposes an improved system for extracting precise cellular impedance in real-time, with a wide bandwidth and satisfactory accuracy. The system hardware consists of five main parts: a microelectrode array (MEA), a stimulation circuit, a sensing circuit, a multi-function card and a computer. The development of system hardware is explored. Accordingly, a novel bioimpedance measurement method coined digital auto balancing bridge method, which is improved from the traditional analogue auto balancing bridge circuitry, is realized for real-time cellular impedance measurement. Two different digital bridge balancing algorithms are proposed and realized, which are based on least mean squares (LMS) algorithm and fast block LMS (FBLMS) algorithm for single- and multi-frequency measurements respectively. Details on their implementation in FPGA are discussed. The test results prove that the LMS-based algorithm is suitable for accelerating the measurement speed in single-frequency situation, whilst the FBLMS-based algorithm has advantages in stable convergence in multi-frequency applications. A novel algorithm, called the All Phase Fast Fourier Transform (APFFT), is applied for post-processing of bioimpedance measurement results. Compared with the classical FFT algorithm, the APFFT significantly reduces spectral leakage caused by truncation error. Compared to the traditional FFT and Digital Quadrature Demodulation (DQD) methods, the APFFT shows excellent performance for extracting accurate phase and amplitude in the frequency spectrum. Additionally, testing and evaluation of the realized system has been performed. The results show that our system achieved a satisfactory accuracy within a wide bandwidth, a fast measurement speed and a good repeatability. Furthermore, our system is compared with a commercial impedance analyzer (Agilent 4294A) in biological experiments. The results reveal that our system achieved a comparable accuracy to the commercial instrument in the biological experiments. Finally, conclusions are given and the future work is proposed

    Non-Destructive Techniques Based on Eddy Current Testing

    Get PDF
    Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. This paper includes an overview of the fundamentals and main variables of eddy current testing. It also describes the state-of-the-art sensors and modern techniques such as multi-frequency and pulsed systems. Recent advances in complex models towards solving crack-sensor interaction, developments in instrumentation due to advances in electronic devices, and the evolution of data processing suggest that eddy current testing systems will be increasingly used in the future

    Bioimpedance spectroscopy - can it be used as a tool for monitoring fluid shifts in burns?

    Get PDF
    Large fluid shifts and oedema are features of burn injuries. Oedema hampers burn wound healing and is directly related to the size and depth of the burn. The degree of oedema in burns covers a broad spectrum: Minor burns cause localised or peripheral oedema, whilst major burns may result in a systemic inflammatory response which can be life threatening and necessitates formal fluid resuscitation. Acute burn fluid resuscitation is paramount in decreasing patient morbidity and mortality but can contribute to already large amounts of oedema. There is currently no single clinically applicable, non-invasive and accurate outcome measure to titrate fluid volumes in acute burns or monitor the effect of treatments on oedema (in minor and major burns). Bioimpedance spectroscopy (BIS) has emerged as a possible solution to these challenges. It can measure body fluid compartments and thus fluid volume changes over time providing a sensitive non-invasive device to estimate resuscitation requirements and oedema change and is emerging as a measure of wound healing. This series of studies therefore aimed to 1) address the potential barriers to use of BIS in the burns population, 2) determine if BIS provides an accurate measure of whole body/systemic fluid volume change and 3) localised burn wound oedema changes, as applied across the spectrum of burn severity, and 4) determine if BIS can monitor wound healing in minor burns. The studies therefore investigated novel whole body and localised electrode positions in the presence of open and dressed wounds, using repeated measures over time in minor and major burns. The key novel findings arising from the research series include: 1) alternate electrode placements are interchangeable with standardised placement for the measurement of whole body resistance, extracellular and total body fluid volumes in specified dressing conditions. Therefore BIS can be utilised to monitor changes in fluid shifts when wounds preclude the manufacturer’s standard placement of electrodes in the presence of burn wounds, 2) BIS is a reliable method of monitoring fluid in any dressing condition and electrode position with no systematic bias indicated in both major and minor burns, 3) In both minor and major burns, BIS is a valid indicator of net fluid shifts and oedema change, if dressing condition is adjusted for using the developed algorithms or calculator and 4) BIS resistance variables, R0 and Rinf, can be used to monitor wound healing in minor limb burns as an adjunct to standard practice

    Medical microprocessor systems

    Get PDF
    The practical classes and laboratory work in the discipline "Medical microprocessor systems", performed using software in the programming environment of microprocessors Texas Instruments (Code Composer Studio) and using of digital microprocessors of the Texas Instruments DSK6400 family, and models of electrical equipment in the environment of graphical programming LabVIEW 2010.Лабораторний практикум з програмування та побудови медичних мікропроцесорних систем, який викладено у навчальному посібнику допомагає накопичувати й ефективно використовувати отриману інформацію з теоретичного курсу на всіх стадіях навчального процесу, що є важливим для підготовки магістрів та необхідною ланкою у науковому пізнанні практичних основ біомедичної електроніки.The laboratory workshop on the programming and construction of medical microprocessor systems, which is outlined in the tutorial, helps to accumulate and effectively use the information obtained from a theoretical course at all stages of the educational process, which is important for the preparation of masters and a necessary link in the scientific knowledge of the practical basics of biomedicine.Лабораторный практикум по программированию и построению медицинских микропроцессорных систем, который изложен в учебном пособии помогает накапливать и эффективно использовать полученную информацию из теоретического курса на всех стадиях учебного процесса, что важно для подготовки магистров и является необходимым звеном в научном познании практических основ биомедицинской электроники

    A Preliminary Study

    Get PDF
    Bioelectrical Impedance Spectroscopy (BIS) allows assessing the composition of body districts noninvasively and quickly, potentially providing important physiological/clinical information. However, neither portable commercial instruments nor more advanced wearable prototypes simultaneously satisfy the demanding needs of unobtrusively tracking body fluid shifts in different segments simultaneously, over a broad frequency range, for long periods and with high measurements rate. These needs are often required to evaluate exercise tests in sports or rehabilitation medicine, or to assess gravitational stresses in aerospace medicine. Therefore, the aim of this work is to present a new wearable prototype for monitoring multi-segment and multi- frequency BIS unobtrusively over long periods. Our prototype guarantees low weight, small size and low power consumption. An analog board with current- injecting and voltage-sensing electrodes across three body segments interfaces a digital board that generates square-wave current stimuli and computes impedance at 10 frequencies from 1 to 796 kHz. To evaluate the information derivable from our device, we monitored the BIS of three body segments in a volunteer before, during and after physical exercise and postural shift. We show that it can describe the dynamics of exercise-induced changes and the effect of a sit-to-stand maneuver in active and inactive muscular districts separately and simultaneously

    A Learning Sensors Platform for Health and Safety Applications

    Get PDF
    corecore