249,415 research outputs found
Reliability of Two Alternative Methods for the Standard Mid-thigh Isometric Pull
The purpose of this study was to determine the reliability of two new alternative portable methods for measuring maximal isometric force measures while performing the standard mid-thigh pull. One method, the bar grip method, required the use of the trunk and upper extremity muscles, while the second method, the pelvic belt method, did not. Both methods demonstrated good test-retest reliability via randomized repeated measures over 24-36 hours. Interestingly, the pelvic belt method generally demonstrated average maximal forces up to 65% higher than the bar method. There was a good relationship between both methods. These new alternative methods could provide strength coaches an option for a more efficient, cost-effective, portable means for the mid-thigh pull test
RELIABILITY OF TWO ALTERNATIVE METHODS FOR THE STANDARD MIDTHIGH ISOMETRIC PULL
The purpose of this study was to determine the reliability of two new alternative portable methods for measuring maximal isometric force measures while performing the standard mid-thigh pull. One method, the bar grip method, required the use of the trunk and upper extremity muscles, while the second method, the pelvic belt method, did not. Both methods demonstrated good test-retest reliability via randomized repeated measures over 24-36 hours. Interestingly, the pelvic belt method generally demonstrated average maximal forces up to 65% higher than the bar method. There was a good relationship between both methods. These new alternative methods could provide strength coaches an option for a more efficient, cost-effective, portable means for the mid-thigh pull test
Lightning testing at the subsystem level
Testing at the subsystem or black box level for lightning hardness is required if system hardness is to be assured at the system level. The often applied philosophy of lighting testing only at the system level leads to extensive end of the line design changes which result in excessive costs and time delays. In order to perform testing at the subsystem level two important factors must be defined to make the testing simulation meaningful. The first factor is the definition of the test stimulus appropriate to the subsystem level. Application of system level stimulations to the subsystem level usually leads to significant overdesign of the subsystem which is not necessary and may impair normal subsystem performance. The second factor is the availability of test equipment needed to provide the subsystem level lightning stimulation. Equipment for testing at this level should be portable or at least movable to enable efficient testing in a design laboratory environment. Large fixed test installations for system level tests are not readily available for use by the design engineers at the subsystem level and usually require special operating skills. The two factors, stimulation level and test equipment availability, must be evaluated together in order to produce a practical, workable test standard. The neglect or subordination of either factor will guarantee failure in generating the standard. It is not unusual to hear that test standards or specifications are waived because a specified stimulation level cannot be accomplished by in-house or independent test facilities. Determination of subsystem lightning simulation level requires a knowledge and evaluation of field coupling modes, peak and median levels of voltages and currents, bandwidths, and repetition rates. Practical limitations on test systems may require tradeoffs in lightning stimulation parameters in order to build practical test equipment. Peak power levels that can be generated at specified bandwidths with standard electrical components must be considered in the design and costing of the test system. Stimulation tests equipment and test methods are closely related and must be considered a test system for lightning simulation. A non-perfect specification that can be reliably and repeatedly applied at the subsystem test level is more desirable than a perfect specification that cannot be applied at all
Precise time dissemination via portable atomic clocks
The most precise operational method of time dissemination over long distances presently available to the Precise Time and Time Interval (PTTI) community of users is by means of portable atomic clocks. The Global Positioning System (GPS), the latest system showing promise of replacing portable clocks for global PTTI dissemination, was evaluated. Although GPS has the technical capability of providing superior world-wide dissemination, the question of present cost and future accessibility may require a continued reliance on portable clocks for a number of years. For these reasons a study of portable clock operations as they are carried out today was made. The portable clock system that was utilized by the U.S. Naval Observatory (NAVOBSY) in the global synchronization of clocks over the past 17 years is described and the concepts on which it is based are explained. Some of its capabilities and limitations are also discussed
Two ways to Grid: the contribution of Open Grid Services Architecture (OGSA) mechanisms to service-centric and resource-centric lifecycles
Service Oriented Architectures (SOAs) support service lifecycle tasks, including Development, Deployment, Discovery and Use. We observe that there are two disparate ways to use Grid SOAs such as the Open Grid Services Architecture (OGSA) as exemplified in the Globus Toolkit (GT3/4). One is a traditional enterprise SOA use where end-user services are developed, deployed and resourced behind firewalls, for use by external consumers: a service-centric (or âfirst-orderâ) approach. The other supports end-user development, deployment, and resourcing of applications across organizations via the use of execution and resource management services: A Resource-centric (or âsecond-orderâ) approach. We analyze and compare the two approaches using a combination of empirical experiments and an architectural evaluation methodology (scenario, mechanism, and quality attributes) to reveal common and distinct strengths and weaknesses. The impact of potential improvements (which are likely to be manifested by GT4) is estimated, and opportunities for alternative architectures and technologies explored. We conclude by investigating if the two approaches can be converged or combined, and if they are compatible on shared resources
Recommended from our members
In-place HEPA filter penetration test
We have demonstrated the feasibility of conducting penetration tests on high efficiency particulate air (HEPA) filters as installed in nuclear ventilation systems. The in-place penetration test, which is designed to yield equivalent penetration measurements as the standard DOP efficiency test, is based on measuring the aerosol penetration of the filter installation as a function of particle size using a portable laser particle counter. This in-place penetration test is compared to the current in-place leak test using light scattering photometers for single HEPA filter installations and for HEPA filter plenums using the shroud method. Test results show the in-place penetration test is more sensitive than the in-place leak test, has a similar operating procedure, but takes longer to conduct. Additional tests are required to confirm that the in-place penetration test yields identical results as the standard dioctyl phthalate (DOP) penetration test for HEPA filters with controlled leaks in the filter and gasket and duct by-pass leaks. Further development of the procedure is also required to reduce the test time before the in- place penetration test is practical
Recommended from our members
Portable Perimetry Using Eye-Tracking on a Tablet ComputerâA Feasibility Assessment
Purpose: Visual field (VF) examination by standard automated perimetry (SAP) is an important method of clinical assessment. However, the complexity of the test, and its use of bulky, expensive equipment makes it impractical for case-finding. We propose and evaluate a new approach to paracentral VF assessment that combines an inexpensive eye-tracker with a portable tablet computer (âEyecatcherâ).
Methods: Twenty-four eyes from 12 glaucoma patients, and 12 eyes from six age-similar controls were examined. Participants were tested monocularly (once per eye), with both the novel Eyecatcher test and traditional SAP (HFA SITA standard 24-2). For Eyecatcher, the participant's task was to simply to look at a sequence of fixed-luminance dots, presented relative to the current point of fixation. Start and end fixations were used to determine locations where stimuli were seen/unseen, and to build a continuous map of sensitivity loss across a VF of approximately 20°.
Results: Eyecatcher was able to clearly separate patients from controls, and the results were consistent with those from traditional SAP. In particular, mean Eyecatcher scores were strongly correlated with mean deviation scores (r2 = 0.64, P < 0.001), and there was good concordance between corresponding VF locations (âŒ84%). Participants reported that Eyecatcher was more enjoyable, easier to perform, and less tiring than SAP (all P < 0.001).
Conclusions: Portable perimetry using an inexpensive eye-tracker and a tablet computer is feasible, although possible means of improvement are suggested.
Translational Relevance: Such a test could have significant utility as a case finding device
Portability of Prolog programs: theory and case-studies
(Non-)portability of Prolog programs is widely considered as an important
factor in the lack of acceptance of the language. Since 1995, the core of the
language is covered by the ISO standard 13211-1. Since 2007, YAP and SWI-Prolog
have established a basic compatibility framework. This article describes and
evaluates this framework. The aim of the framework is running the same code on
both systems rather than migrating an application. We show that today, the
portability within the family of Edinburgh/Quintus derived Prolog
implementations is good enough to allow for maintaining portable real-world
applications.Comment: Online proceedings of the Joint Workshop on Implementation of
Constraint Logic Programming Systems and Logic-based Methods in Programming
Environments (CICLOPS-WLPE 2010), Edinburgh, Scotland, U.K., July 15, 201
Material selection for a new type of fire extinguisher
Nowadays safety is a hot topic, damage inflicted to human beings is intolerable. Fire safety is a big concern in industrial areas, but in residential areas a lot less precautions are in place. Therefore a new type of fire extinguisher should be developed that should encourage the installation of fire extinguishers in commercial environments and at home. The design of this fire extinguisher has to answer to a lot of demands. From a legal point of view, the extinguisher has to comply with the PED regulations and the EN 3 standard. Extra demands are, given the purpose, superb performance, great ergonomics and an attractive visual design. One of the steps in the design process is to make a material selection based on needed and desired properties of materials. Also the possible processes for manufacturing are an important parameter
Commercialisation of precision agriculture technologies in the macadamia industry
A prototype vision-based yield monitor has been developed for the macadamia industry. The system estimates yield for individual trees by detecting nuts and their harvested location. The technology was developed by the National Centre for Engineering in Agriculture, University of Southern Queensland for the purpose of reducing labour and costs in varietal assessment trials where yield for individual trees are required to be measured to indicate tree performance. The project was commissioned by Horticulture Australia Limited
- âŠ