    Noncontact blood perfusion mapping in clinical applications

    Get PDF
    © 2016 SPIE.Non-contact imaging photoplethysmography (iPPG) to detect pulsatile blood microcirculation in tissue has been selected as a successor to low spatial resolution and slow scanning blood perfusion techniques currently employed by clinicians. The proposed iPPG system employs a novel illumination source constructed of multiple high power LEDs with narrow spectral emission, which are temporally modulated and synchronised with a high performance sCMOS sensor. To ensure spectrum stability and prevent thermal wavelength drift due to junction temperature variations, each LED features a custom-designed thermal management system to effectively dissipate generated heat and auto-adjust current flow. The use of a multi-wavelength approach has resulted in simultaneous microvascular perfusion monitoring at various tissue depths, which is an added benefit for specific clinical applications. A synchronous detection algorithm to extract weak photoplethysmographic pulse-waveforms demonstrated robustness and high efficiency when applied to even small regions of 5 mm2. The experimental results showed evidences that the proposed system could achieve noticeable accuracy in blood perfusion monitoring by creating complex amplitude and phase maps for the tissue under examination

    Employment of artificial intelligence mechanisms for e-Health systems in order to obtain vital signs and detect diseases from medical images improving the processes of online consultations and diagnosis

    Get PDF
    Nowadays e-Health web applications allow doctors to access different types of features, such as knowing which medication the patient has consumed or performing online consultations. Internet systems for healthcare can be improved by using artificial intelligence mechanisms for the process of detecting diseases and obtaining biological data, allowing medical professionals to have important information that facilitates the diagnosis process and the choice of the correct treatment for each particular person. The proposed research work aims to present an innovative approach when compared to traditional platforms, by providing online vital signs in real time, access to a web stethoscope, to a medical image uploader that predicts if a certain disease is present, through deep learning methods, and also allows the visualization of all historical data of a patient. This dissertation has the objective of defending the concept of online consultations, providing complementary functionalities to the traditional methods for performing medical diagnoses through the use of software engineering practices. The process of obtaining vital signs was done via artificial intelligence using a computer camera as sensor. This methodology requires that the user is at a state of rest during the measurements. This investigation led to the conclusion that, in the future, many medical processes will most likely be done online, where this practice is considered extremely helpful for the analysis and treatment of contagious diseases, or cases that require constant monitoring.No quotidiano, as aplicações Web e-Saúde permitem aos médicos acesso a diferentes tipos de funcionalidades, como saber qual a medicação que o doente consumiu ou a realização de consultas online. Os sistemas via internet para a saúde podem ser melhorados, utilizando mecanismos de inteligência artificial para os processos de deteção de doenças e de obtenção de dados biológicos, permitindo que os médicos tenham informações importantes que facilitam o processo de diagnóstico ou a escolha do tratamento correto para um determinado utente. O trabalho de investigação proposto pretende apresentar uma abordagem inovadora na comparação com as plataformas tradicionais, ao disponibilizar sinais vitais online em tempo real, acesso a um estetoscópio web, a um uploader de imagens médicas que prevê se uma determinada doença está presente, através de métodos de aprendizagem profunda, bem como permite visualizar todos os dados históricos de um paciente. Esta dissertação visa defender o conceito de consultas virtuais, providenciando funcionalidades complementares aos processos tradicionais de realização de um diagnóstico médico, através da utilização de práticas de engenharia de software. O processo de obtenção de sinais vitais foi feito através de inteligência artificial para visão computacional utilizando uma câmara de computador. Esta metodologia requer que o utilizador esteja em estado de repouso durante a obtenção dos dados medidos. Esta investigação permitiu concluir que, no futuro, muitos processos médicos atuais provavelmente serão feitos online, sendo esta prática considerada extremamente útil na análise e tratamento de doenças contagiosas, ou de casos que requerem acompanhamento constante

    Use of ambient light in remote photoplethysmographic systems: comparison between a high-performance camera and a low-cost webcam

    Get PDF
    Imaging photoplethysmography (PPG) is able to capture useful physiological data remotely from a wide range of anatomical locations. Recent imaging PPG studies have concentrated on two broad research directions involving either high-performance cameras and or webcam-based systems. However, little has been reported about the difference between these two techniques, particularly in terms of their performance under illumination with ambient light. We explore these two imaging PPG approaches through the simultaneous measurement of the cardiac pulse acquired from the face of 10 male subjects and the spectral characteristics of ambient light. Measurements are made before and after a period of cycling exercise. The physiological pulse waves extracted from both imaging PPG systems using the smoothed pseudo-Wigner-Ville distribution yield functional characteristics comparable to those acquired using gold standard contact PPG sensors. The influence of ambient light intensity on the physiological information is considered, where results reveal an independent relationship between the ambient light intensity and the normalized plethysmographic signals. This provides further support for imaging PPG as a means for practical noncontact physiological assessment with clear applications in several domains, including telemedicine and homecare

    Photoplethysmographic imaging and analysis of pulsatile pressure wave in palmar artery at 10 wavelengths

    Get PDF
    CC BY: © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.Significance As a noncontact method, imaging photoplethysmography (iPPG) may provide a powerful tool to measure pulsatile pressure wave (PPW) in superficial arteries and extract biomarkers for monitoring of artery wall stiffness. Aim We intend to develop a approach for extraction of the very weak cardiac component from iPPG data by identifying locations of strong PPW signals with optimized illumination wavelength and determining pulse wave velocity (PWV). Approach Monochromatic in vivo iPPG datasets have been acquired from left hands to investigate various algorithms for retrieval of PPW signals, distribution maps and waveforms, and their dependence on arterial location and wavelength. Results A robust algorithm of pixelated independent component analysis (pICA) has been developed and combined with spatiotemporal filtering to retrieve PPW signals. Spatial distributions of PPW signals have been mapped in 10 wavelength bands from 445 to 940 nm and waveforms were analyzed at multiple locations near the palmar artery tree. At the wavelength of 850 nm selected for timing analysis, we determined PWV values from 12 healthy volunteers in a range of 0.5 to 5.8 m/s across the hand region from wrist to midpalm and fingertip.ECU Open Access Publishing Support Fun

    A Wearable System for Real-Time Continuous Monitoring of Physical Activity

    Get PDF
    Over the last decades, wearable systems have gained interest for monitoring of physiological variables, promoting health, and improving exercise adherence in different populations ranging from elite athletes to patients. In this paper, we present a wearable system for the continuous real-time monitoring of respiratory frequency (fR), heart rate (HR), and movement cadence during physical activity. The system has been experimentally tested in the laboratory (by simulating the breathing pattern with a mechanical ventilator) and by collecting data from one healthy volunteer. Results show the feasibility of the proposed device for real-time continuous monitoring of fR, HR, and movement cadence both in resting condition and during activity. Finally, different synchronization techniques have been investigated to enable simultaneous data collection from different wearable modules.Ministerio de Economía y Competitivida

    Remote simultaneous dual wavelength imaging photoplethysmography: a further step towards 3-D mapping of skin blood microcirculation

    Get PDF
    This paper presents a camera-based imaging photoplethysmographic (PPG) system in the remote detection of PPG signals, which can contribute to construct a 3-D blood pulsation mapping for the assessment of skin blood microcirculation at various vascular depths. Spot measurement and contact sensor have been currently addressed as the primary limitations in the utilization of conventional PPG system. The introduction of the fast digital camera inspires the development of the imaging PPG system to allow ideally non-contact monitoring from a larger field of view and different tissue depths by applying multi-wavelength illumination sources. In the present research, the imaging PPG system has the capability of capturing the PPG waveform at dual wavelengths simultaneously: 660 and 880nm. A selected region of tissue is remotely illuminated by a ring illumination source (RIS) with dual-wavelength resonant cavity light emitting diodes (RCLEDs), and the backscattered photons are captured by a 10-bit CMOS camera at a speed of 21 frames/second for each wavelength. The waveforms from the imaging system exhibit comparable functionality characters with those from the conventional contact PPG sensor in both time domain and frequency domain. The mean amplitude of PPG pulsatile component is extracted from the PPG waveforms for the mapping of blood pulsation in a 3-D format. These results strongly demonstrate the capability of the imaging PPG system in displaying the waveform and the potential in 3-D mapping of blood microcirculation by a non-contact means