Sampling from a system-theoretic viewpoint
This paper studies a system-theoretic approach to the problem of reconstructing an analog signal from its samples. The idea, borrowed from earlier treatments in the control literature, is to address the problem as a hybrid model-matching problem in which performance is measured by system norms. \ud
\ud
The paper is split into three parts. In Part I we present the paradigm and revise the lifting technique, which is our main technical tool. In Part II optimal samplers and holds are designed for various analog signal reconstruction problems. In some cases one component is fixed while the remaining are designed, in other cases all three components are designed simultaneously. No causality requirements are imposed in Part II, which allows to use frequency domain arguments, in particular the lifted frequency response as introduced in Part I. In Part III the main emphasis is placed on a systematic incorporation of causality constraints into the optimal design of reconstructors. We consider reconstruction problems, in which the sampling (acquisition) device is given and the performance is measured by the -norm of the reconstruction error. The problem is solved under the constraint that the optimal reconstructor is -causal for a given i.e., that its impulse response is zero in the time interval where is the sampling period. We derive a closed-form state-space solution of the problem, which is based on the spectral factorization of a rational transfer function
Design, analysis and evaluation of sigma-delta based beamformers for medical ultrasound imaging applications
The inherent analogue nature of medical ultrasound signals in conjunction with the abundant merits provided by digital image acquisition, together with the increasing use of relatively simple front-end circuitries, have created considerable demand for single-bit beamformers in digital ultrasound imaging systems. Furthermore, the increasing need to design lightweight ultrasound systems with low power consumption and low noise, provide ample justification for development and innovation in the use of single-bit beamformers in ultrasound imaging systems. The overall aim of this research program is to investigate, establish, develop and confirm through a combination of theoretical analysis and detailed simulations, that utilize raw phantom data sets, suitable techniques for the design of simple-to-implement hardware efficient digital ultrasound beamformers to address the requirements for 3D scanners with large channel counts, as well as portable and lightweight ultrasound scanners for point-of-care applications and intravascular imaging systems.
In addition, the stability boundaries of higher-order High-Pass (HP) and Band-Pass (BP) Σ−Δ modulators for single- and dual- sinusoidal inputs are determined using quasi-linear modeling together with the describing-function method, to more accurately model the modulator quantizer. The theoretical results are shown to be in good agreement with the simulation results for a variety of input amplitudes, bandwidths, and modulator orders. The proposed mathematical models of the quantizer will immensely help speed up the design of higher order HP and BP Σ−Δ modulators to be applicable for digital ultrasound beamformers.
Finally, a user friendly design and performance evaluation tool for LP, BP and HP modulators is developed. This toolbox, which uses various design methodologies and covers an assortment of modulators topologies, is intended to accelerate the design process and evaluation of modulators. This design tool is further developed to enable the design, analysis and evaluation of beamformer structures including the noise analyses of the final B-scan images. Thus, this tool will allow researchers and practitioners to design and verify different reconstruction filters and analyze the results directly on the B-scan ultrasound images thereby saving considerable time and effort
A Novel Iterative Structure for Online Calibration of M-Channel Time-Interleaved ADCs
published_or_final_versio
Bacterial Foraging Based Channel Equalizers
A channel equalizer is one of the most important subsystems in any digital
communication receiver. It is also the subsystem that consumes maximum computation
time in the receiver. Traditionally maximum-likelihood sequence estimation (MLSE) was
the most popular form of equalizer. Owing to non-stationary characteristics of the
communication channel MLSE receivers perform poorly. Under these circumstances
‘Maximum A-posteriori Probability (MAP)’ receivers also called Bayesian receivers
perform better.
Natural selection tends to eliminate animals with poor “foraging strategies” and favor the
propagation of genes of those animals that have successful foraging strategies since they
are more likely to enjoy reproductive success. After many generations, poor foraging
strategies are either eliminated or shaped into good ones (redesigned). Logically, such
evolutionary principles have led scientists in the field of “foraging theory” to
hypothesize that it is appropriate to model the activity of foraging as an optimization
process.
This thesis presents an investigation on design of bacterial foraging based channel
equalizer for digital communication. Extensive simulation studies shows that the
performance of the proposed receiver is close to optimal receiver for variety of channel
conditions. The proposed receiver also provides near optimal performance when channel
suffers from nonlinearities
Recommended from our members
Ultimate iterative UFIR filtering algorithm
Measurements are often provided in the presence of noise and uncertainties that require optimal filters to estimate processes with highest accuracy. The ultimate iterative unbiased finite impulse response (UFIR) filtering algorithm presented in this paper is more robust in real world than the Kalman filter. It completely ignores the noise statistics and initial values while demonstrating better accuracy under the mismodeling and temporary uncertainties and lower sensitivity to errors in the noise statistics
Digital signal processing for segmented HPGe detectors preprocessingalgorithms and pulse shape analysis
MINIBALL is an versatile spectrometer consisting of 24 longitudinally six-fold segmented HPGe detectors, build for the efficient detection of rare γ decays in nuclear reactions of radioactive ion beams. MINIBALL was the first spectrometer equipped with digital electronics. Pulse shape analysis algorithms to determine the interaction position of γ -rays were implemented on a Digital Signal Processor and validated in an experiment using a collimated γ -ray source. Emphasis was placed on the properties of the different digital signal processing algorithms, the consequences for the implementation and the applicability for position determination. The next generation of γ -ray spectrometers will consist of highly segmented HPGe detectors equipped with digital electronics, resulting in a more than ten-fold increase in complexity compared to current spectrometers. To enable the construction of a γ -ray tracking spectrometer, new and powerful digital electronics will be developed. Preprocessing algorithms, giving the γ -ray energy and generating event triggers, were implemented on a VME module equipped with fast A/D converters and tested with different detectors and sources. Emphasis was placed on the detailed simulation and understanding of the algorithms as well as the influence of electronics and detector onto the energy resolution
- …