    Towards better reliability in fetal heart rate variability using time domain and spectral domain analyses. A new method for assessing fetal neurological state?

    Get PDF
    OBJECTIVES: Fetal heart rate variability (FHRV) has shown potential in fetal surveillance. Therefore, we aimed to evaluate the reliability of time domain and spectral domain parameters based on non-invasive fetal electrocardiography (NI-FECG). METHOD: NI-FECG, with a sampling frequency of 1 kHz, was obtained in 75 healthy, singleton pregnant women between gestational age (GA) 20(+0) to 41(+0). The recording was divided into a) heart rate pattern (HRP) and b) periods fulfilling certain criteria of stationarity of RR-intervals, termed stationary heart rate pattern (SHRP). Within each recording, the first and the last time series from each HRP with less than 5% artifact correction were analyzed and compared. Standard deviation of normal-to-normal RR-intervals (SDNN), root mean square of successive differences (RMSSD), high frequency power (HF-power), low frequency power (LF-power), and LF-power/HF-power were performed. A multivariate mixed model was used and acceptable reliability was defined as intraclass correlation coefficient (ICC) ≥ 0.80 and a coefficient of variation (CV) ≤ 15%. Based on these results, the CV and ICC were computed if the average of two to six time series was used. RESULTS: For GA 28(+0) to 34(+6), SDNN and RMSSD exhibited acceptable reliability (CV 90%), whereas GA 35(+0) to 41(+0)and 20(+0) to 27(+6) showed higher CVs. Spectral domain parameters also showed high CVs However, by using the mean value of two to six time series, acceptable reliability in SDNN, RMSSD and HF-power from GA 28(+0) was achieved. Stationarity of RR-intervals showed high influence on reliability and SHRP was superior to HRP, whereas the length of the time series showed minor influence. CONCLUSION: Acceptable reliability seems achievable in SDNN, RMSSD and HF-power from gestational week 28. However, stationarity of RR-intervals should be considered when selecting time series for analyses

    Fetal respiratory movements improve reliability of heart rate variability and suggest a coupling between fetal respiratory arrhythmia and vagal activity

    Get PDF
    Fetal heart rate variability (FHRV) reflects autonomic cardiac regulation. The autonomic nervous system constantly adjusts the heart rate to maintain homeostasis. By providing insight into the fetal autonomic state, FHRV has the potential to become an investigational and clinical instrument. However, the method needs standardization and the influence of fetal movements, including fetal respiratory movements, is not well explored. Therefore, in a highly standardized setting, the aim was to evaluate the association between fetal movements and fetal heart rate variability (FHRV) including their impact on reliability. Fetal heart rate was obtained by noninvasive fetal electrocardiography (NI‐FECG) and fetal movements by simultaneous ultrasound scanning in 30 healthy singleton pregnant women on two occasions with a maximum interval of 7 days. The standard deviation of normal‐to‐normal RR‐intervals (SDNN), root mean square of successive RR‐interval differences (RMDDS), high‐frequency power (HF‐power), low‐frequency power (LF‐power), and LF/HF were measured. A multivariate mixed model was used and reliability was defined as acceptable by a coefficient of variance (CV) ≤15% and an intraclass correlation coefficient (ICC) ≥0.80. During time periods with fetal respiratory movements, the highest reliability was achieved. Intra‐ and inter‐observer reliability measurements were very high (CV: 0–9%; ICC ≧ 0.86). Within the same recording, SDNN and RMSSD achieved acceptable reliability (CV: 14–15%; ICC ≧ 0.80). However, day‐to‐day reliability displayed high CV’s. In time periods with fetal respiratory movements, as compared to periods with quiescence RMSSD and HF‐power were higher (Ratio: 1.33–2.03) and LF/HF power lower (Ratio: 0.54). In periods with fetal body movements SDNN, RMSSD and HF‐power were higher (Ratio: 1.27–1.65). In conclusion, time periods with fetal respiratory movements were associated with high reliability of FHRV analyses and the highest values of parameters supposed to represent vagal activity

    Diagnostic opportunities of transabdominal fetal electrocardiography

    Get PDF

    Diagnostic opportunities of transabdominal fetal electrocardiography

    Get PDF

    Fetal Myocardial Performance Index in the Third Trimester of Pregnancy: Feasibility and Reproducibility of Conventional Spectral Doppler versus Spectral Tissue Doppler Technique

    Get PDF
    Objective: This study aims to compare completion rates and reproducibility of myocardial performance index (MPI) using conventional spectral Doppler versus tissue Doppler in an unselected high-risk third trimester population. Study Design: This was a prospective cross-sectional study of high-risk pregnancies at ≥28 + 0 weeks’ gestation. Conventional spectral and tissue Doppler MPI of the left ventricle (LV) and right ventricle (RV) was attempted on all patients. Results: Seventy-nine pregnancies were evaluated. LV tissue Doppler MPI was completed more frequently than LV conventional spectral Doppler MPI (63/79, 79.7% vs. 45/79, 55.7%), p-value Conclusion: Tissue Doppler had statistically higher completion rates than conventional spectral Doppler, including the obese subgroup, with evidence of strong reproducibility in the third trimester

    Extracting fetal heart beats from maternal abdominal recordings: Selection of the optimal principal components

    Get PDF
    This study presents a systematic comparison of different approaches to the automated selection of the principal components (PC) which optimise the detection of maternal and fetal heart beats from non-invasive maternal abdominal recordings. A public database of 75 4-channel non-invasive maternal abdominal recordings was used for training the algorithm. Four methods were developed and assessed to determine the optimal PC: (1) power spectral distribution, (2) root mean square, (3) sample entropy, and (4) QRS template. The sensitivity of the performance of the algorithm to large-amplitude noise removal (by wavelet de-noising) and maternal beat cancellation methods were also assessed. The accuracy of maternal and fetal beat detection was assessed against reference annotations and quantified using the detection accuracy score F1 [2*PPV*Se / (PPV + Se)], sensitivity (Se), and positive predictive value (PPV). The best performing implementation was assessed on a test dataset of 100 recordings and the agreement between the computed and the reference fetal heart rate (fHR) and fetal RR (fRR) time series quantified. The best performance for detecting maternal beats (F1 99.3%, Se 99.0%, PPV 99.7%) was obtained when using the QRS template method to select the optimal maternal PC and applying wavelet de-noising. The best performance for detecting fetal beats (F1 89.8%, Se 89.3%, PPV 90.5%) was obtained when the optimal fetal PC was selected using the sample entropy method and utilising a fixed-length time window for the cancellation of the maternal beats. The performance on the test dataset was 142.7 beats2/min2 for fHR and 19.9 ms for fRR, ranking respectively 14 and 17 (out of 29) when compared to the other algorithms presented at the Physionet Challenge 2013

    Growth-restricted human fetuses have preserved respiratory sinus arrhythmia but reduced heart rate variability estimates of vagal activity during quiescence

    Get PDF
    The aim was to assess the association between fetal growth restriction (FGR) and fetal heart rate variability (FHRV) in relation to fetal movements. A prospective observational cohort study was performed. Non‐invasive fetal electrocardiography (NI‐FECG) allowed beat‐to‐beat assessments with <5% corrections of RR intervals. FHRV analyses included: Root mean square of successive RR interval differences (RMSSD), high frequency power (HF power), and low frequency power (LF power). Fetal movements were categorized by continuous ultrasound scanning. We enrolled 36 singleton pregnant women expecting a small fetus (< the 2.3 percentile of mean weight for gestational age) diagnosed by ultrasound, of whom 25 presented with a birthweight < the 2.3 percentile. Among these, 11 were excluded due to low quality NI‐FECG recordings, leaving 14 women with 28 recordings eligible for inclusion in the analyses. The control group consisted of 22 healthy fetuses with birthweights between the 10th and the 90th percentile (average for gestational age [AGA]). In FGR fetuses the HRV response to respiratory activity was comparable to that of AGA fetuses. RMSSD (Ratio 1.54 [95% CI: 1.33; 1.79]) and HF power (Ratio 2.88 [95% CI: 2.12; 3.91]) increased, whereas LF/HF power (Ratio: 0.44 [95% CI: 0.31;0.63]) decreased. However, during fetal quiescence, FGR fetuses differed significantly from AGA fetuses. Compared to AGA fetuses, FGR fetuses displayed lower RMSSD (Ratio 0.77 (95% CI: 0.58; 1.02)) and HF power (Ratio 0.56 (95% CI:0.32; 0.98)). This reduction was associated with the severity of the FGR. In conclusion, FGR fetuses displayed a respiratory sinus arrhythmia (RSA) comparable to AGA fetuses; however, more important, parameters representing cardiac vagal activity were impaired in FGR fetuses during quiescence. RSA may constitute an intrinsic function of the cardiovascular system, which is unaffected by fetal compromise. However, the basic cardiac outflow assessed during fetal quiescence indicates a suppressed cardiac vagal activity in the FGR fetuses

    Monitoring Fetal Heart Rate during Pregnancy: Contributions from Advanced Signal Processing and Wearable Technology

    Get PDF
    Monitoring procedures are the basis to evaluate the clinical state of patients and to assess changes in their conditions, thus providing necessary interventions in time. Both these two objectives can be achieved by integrating technological development with methodological tools, thus allowing accurate classification and extraction of useful diagnostic information. The paper is focused on monitoring procedures applied to fetal heart rate variability (FHRV) signals, collected during pregnancy, in order to assess fetal well-being. The use of linear time and frequency techniques as well as the computation of non linear indices can contribute to enhancing the diagnostic power and reliability of fetal monitoring. The paper shows how advanced signal processing approaches can contribute to developing new diagnostic and classification indices. Their usefulness is evaluated by comparing two selected populations: normal fetuses and intra uterine growth restricted (IUGR) fetuses. Results show that the computation of different indices on FHRV signals, either linear and nonlinear, gives helpful indications to describe pathophysiological mechanisms involved in the cardiovascular and neural system controlling the fetal heart. As a further contribution, the paper briefly describes how the introduction of wearable systems for fetal ECG recording could provide new technological solutions improving the quality and usability of prenatal monitoring. Š 2014 Maria G. Signorini et al
    • …