62 research outputs found

    Effectiveness of robotic exoskeletons for improving gait in children with cerebral palsy: a systematic review

    Get PDF
    Abstract Background: Robotic exoskeletons have been developed to assist locomotion and address gait abnormalities in children with cerebral palsy (CP). These wearable assistive devices provide powered assistance to the lower-extremity joints, as well as support and stability. Research Question: Does exoskeleton-assisted walking improve gait in children with CP? Methods: The PRISMA guidelines were used to conduct this systematic review. Articles were obtained in a search of the following electronic databases: Embase, CINAHL Complete, PubMed, Web of Science and MEDLINE. Studies investigating spatiotemporal, kinematic, kinetic, muscle activity and/or physiological parameters during exoskeleton-assisted walking in children with CP were included. All articles were assessed for methodological quality using an adapted version of the Quality Assessment Tool for Before-After (Pre-Post) Studies with No Control Group, provided by NIH. Results: Thirteen studies were included. They involved the use of the following exoskeletons: tethered knee exoskeleton, pediatric knee exoskeleton (P.REX), untethered ankle exoskeleton, WAKE-Up ankle module, WAKE-Up ankle & knee module and unilateral ankle exosuit. Methodological quality varied, with key limitations in sample size and allocated time to adapt to the exoskeleton. There was a consensus that robotic exoskeletons improve gait given careful optimisation of exoskeleton torque and sufficient exoskeleton practice time for each participant. Improvements in gait included reduced metabolic cost of walking, increased walking speed, and increased knee and hip extension during stance. Furthermore, exoskeletons with an actuated ankle module were shown to promote normal ankle rocker function. Significance: Robotic exoskeletons have the potential to improve the mobility of CP children and may therefore increase community participation and improve quality of life. Future work should involve larger controlled intervention studies utilising robotic exoskeletons to improve gait in children with CP. These studies should ensure sufficient exoskeleton practice time for each participant

    Comfort-Centered Design of a Lightweight and Backdrivable Knee Exoskeleton

    Full text link
    This paper presents design principles for comfort-centered wearable robots and their application in a lightweight and backdrivable knee exoskeleton. The mitigation of discomfort is treated as mechanical design and control issues and three solutions are proposed in this paper: 1) a new wearable structure optimizes the strap attachment configuration and suit layout to ameliorate excessive shear forces of conventional wearable structure design; 2) rolling knee joint and double-hinge mechanisms reduce the misalignment in the sagittal and frontal plane, without increasing the mechanical complexity and inertia, respectively; 3) a low impedance mechanical transmission reduces the reflected inertia and damping of the actuator to human, thus the exoskeleton is highly-backdrivable. Kinematic simulations demonstrate that misalignment between the robot joint and knee joint can be reduced by 74% at maximum knee flexion. In experiments, the exoskeleton in the unpowered mode exhibits 1.03 Nm root mean square (RMS) low resistive torque. The torque control experiments demonstrate 0.31 Nm RMS torque tracking error in three human subjects.Comment: 8 pages, 16figures, Journa

    A Pediatric Knee Exoskeleton With Real-Time Adaptive Control for Overground Walking in Ambulatory Individuals With Cerebral Palsy

    Get PDF
    Gait training via a wearable device in children with cerebral palsy (CP) offers the potential to increase therapy dosage and intensity compared to current approaches. Here, we report the design and characterization of a pediatric knee exoskeleton (P.REX) with a microcontroller based multi-layered closed loop control system to provide individualized control capability. Exoskeleton performance was evaluated through benchtop and human subject testing. Step response tests show the averaged 90% rise was 26 ± 0.2 ms for 5 Nm, 22 ± 0.2 ms for 10 Nm, 32 ± 0.4 ms for 15 Nm. Torque bandwidth of P.REX was 12 Hz and output impedance was less than 1.8 Nm with control on (Zero mode). Three different control strategies can be deployed to apply assistance to knee extension: state-based assistance, impedance-based trajectory tracking, and real-time adaptive control. One participant with typical development (TD) and one participant with crouch gait from CP were recruited to evaluate P.REX in overground walking tests. Data from the participant with TD were used to validate control system performance. Kinematic and kinetic data were collected by motion capture and compared to exoskeleton on-board sensors to evaluate control system performance with results demonstrating that the control system functioned as intended. The data from the participant with CP are part of a larger ongoing study. Results for this participant compare walking with P.REX in two control modes: a state-based approach that provided constant knee extension assistance during early stance, mid-stance and late swing (Est+Mst+Lsw mode) and an Adaptive mode providing knee extension assistance proportional to estimated knee moment during stance. Both were well tolerated and significantly improved knee extension compared to walking without extension assistance (Zero mode). There was less reduction in gait speed during use of the adaptive controller, suggesting that it may be more intuitive than state-based constant assistance for this individual. Future work will investigate the effects of exoskeleton assistance during overground gait training in children with neurological disorders and will aim to identify the optimal individualized control strategy for exoskeleton prescription

    Intramuscular EMG-driven Musculoskeletal Modelling: Towards Implanted Muscle Interfacing in Spinal Cord Injury Patients

    Get PDF
    Objective: Surface EMG-driven modelling has been proposed as a means to control assistive devices by estimating joint torques. Implanted EMG sensors have several advantages over wearable sensors but provide a more localized information on muscle activity, which may impact torque estimates. Here, we tested and compared the use of surface and intramuscular EMG measurements for the estimation of required assistive joint torques using EMG driven modelling. Methods: Four healthy subjects and three incomplete spinal cord injury (SCI) patients performed walking trials at varying speeds. Motion capture marker trajectories, surface and intramuscular EMG, and ground reaction forces were measured concurrently. Subject-specific musculoskeletal models were developed for all subjects, and inverse dynamics analysis was performed for all individual trials. EMG-driven modelling based joint torque estimates were obtained from surface and intramuscular EMG. Results: The correlation between the experimental and predicted joint torques was similar when using intramuscular or surface EMG as input to the EMG-driven modelling estimator in both healthy individuals and patients. Conclusion: We have provided the first comparison of non-invasive and implanted EMG sensors as input signals for torque estimates in healthy individuals and SCI patients. Significance: Implanted EMG sensors have the potential to be used as a reliable input for assistive exoskeleton joint torque actuation

    The design and testing of a powered exoskeleton to reduce the metabolic cost of walking in individuals with cerebral palsy

    Get PDF
    Cerebral palsy (CP) is the most common form of motor impairment in children. Although CP is a non-progressive neurodevelopmental disorder, its secondary effects can lead to a decline in mobility over time. Eventually, individuals with CP may lose all ambulatory function. Interventions for CP, such as surgery and physical therapy, seek to delay the decline and improve mobility. Research into alternative interventions attempt to find improved outcomes over the traditional treatments. Robot-assistive devices are one such intervention that makes use of powered actuation, sensing, and control to help individuals with CP to retain and improve mobility. The purpose of this research was to develop and test a robot-assistive device that reduces the metabolic cost of walking in children and young adults with CP. Our device consisted of an actuator-and-control module worn on the back, and two custom ankle-foot orthotics (AFOs). The control module contained brushless DC motors, electronics to control actuation, and a power supply. Plantarflexion, or “push-off”, assistive torque was transferred from the motors to the orthotics using Bowden cables. 32-Bit ARM microcontrollers operated the system with inputs from force sensitive resistors (FSR) placed under the ball of each foot, and torque sensors aligned with each ankle joint. Proportional gain control was used to control motor output torque. We implemented a two-state Finite State Machine (FSM) to control the timing of assistance. We completed a pilot study with three participants with CP. We used indirect calorimetry to estimate metabolic cost. The study participants walked under three conditions: baseline, zero-torque, and powered assist. During the baseline condition, participants walked using their own shoes/AFOs and not our device. During the zero-torque condition, participants wore the device and the motors actively maintained a zero-torque reading at the ankle. During the assisted condition, participants wore the device while the motors gave plantarflexion assistance during late stance. Two participants had a decrease in metabolic cost between baseline and assisted conditions, an average of 16.5%. All participants showed an average reduction in the metabolic cost of walking of 40% between the zero-torque condition and the assisted condition, on average. Our youngest and lightest participant (5 years old, 16 kg) did not show a net decrease in metabolic cost between baseline and assisted walking, a result likely due to our device being a large percentage of their total mass, 12.5% as opposed to 7.5% and 4.4%. We conclude that our device shows a strong potential for clinically-relevant applications. Further studies may show that robotic-assistance can improve mobility and quality of life in individuals with CP

    Intramuscular EMG-driven musculoskeletal modelling: towards implanted muscle interfacing in spinal cord injury patients

    Get PDF
    OBJECTIVE: Surface EMG-driven modelling has been proposed as a means to control assistive devices by estimating joint torques. Implanted EMG sensors have several advantages over wearable sensors but provide a more localized information on muscle activity, which may impact torque estimates. Here, we tested and compared the use of surface and intramuscular EMG measurements for the estimation of required assistive joint torques using EMG driven modelling. METHODS: Four healthy subjects and three incomplete spinal cord injury (SCI) patients performed walking trials at varying speeds. Motion capture marker trajectories, surface and intramuscular EMG, and ground reaction forces were measured concurrently. Subject-specific musculoskeletal models were developed for all subjects, and inverse dynamics analysis was performed for all individual trials. EMG-driven modelling based joint torque estimates were obtained from surface and intramuscular EMG. RESULTS: The correlation between the experimental and predicted joint torques was similar when using intramuscular or surface EMG as input to the EMG-driven modelling estimator in both healthy individuals and patients. CONCLUSION: We have provided the first comparison of non-invasive and implanted EMG sensors as input signals for torque estimates in healthy individuals and SCI patients. SIGNIFICANCE: Implanted EMG sensors have the potential to be used as a reliable input for assistive exoskeleton joint torque actuation

    Wearable Lower-Limb Exoskeleton for Children With Cerebral Palsy: A Systematic Review of Mechanical Design, Actuation Type, Control Strategy, and Clinical Evaluation

    Get PDF
    Children with a neurological disorder such as cerebral palsy (CP) severely suffer from a reduced quality of life because of decreasing independence and mobility. Although there is no cure yet, a lower-limb exoskeleton (LLE) has considerable potential to help these children experience better mobility during overground walking. The research in wearable exoskeletons for children with CP is still at an early stage. This paper shows that the number of published papers on LLEs assisting children with CP has significantly increased in recent years; however, no research has been carried out to review these studies systematically. To fill up this research gap, a systematic review from a technical and clinical perspective has been conducted, based on the PRISMA guidelines, under three extended topics associated with “lower limb”, “exoskeleton”, and “cerebral palsy” in the databases Scopus and Web of Science. After applying several exclusion criteria, seventeen articles focused on fifteen LLEs were included for careful consideration. These studies address some consistent positive evidence on the efficacy of LLEs in improving gait patterns in children with CP. Statistical findings show that knee exoskeletons, brushless DC motors, the hierarchy control architecture, and CP children with spastic diplegia are, respectively, the most common mechanical design, actuator type, control strategy, and clinical characteristics for these LLEs. Clinical studies suggest ankle-foot orthosis as the primary medical solution for most CP gait patterns; nevertheless, only one motorized ankle exoskeleton has been developed. This paper shows that more research and contribution are needed to deal with open challenges in these LLEs

    Intramuscular EMG-Driven Musculoskeletal Modelling: Towards Implanted Muscle Interfacing in Spinal Cord Injury Patients

    Get PDF
    Objective: Surface EMG-driven modelling has been proposed as a means to control assistive devices by estimating joint torques. Implanted EMG sensors have several advantages over wearable sensors but provide a more localized information on muscle activity, which may impact torque estimates. Here, we tested and compared the use of surface and intramuscular EMG measurements for the estimation of required assistive joint torques using EMG driven modelling. Methods: Four healthy subjects and three incomplete spinal cord injury (SCI) patients performed walking trials at varying speeds. Motion capture marker trajectories, surface and intramuscular EMG, and ground reaction forces were measured concurrently. Subject-specific musculoskeletal models were developed for all subjects, and inverse dynamics analysis was performed for all individual trials. EMG-driven modelling based joint torque estimates were obtained from surface and intramuscular EMG. Results: The correlation between the experimental and predicted joint torques was similar when using intramuscular or surface EMG as input to the EMG-driven modelling estimator in both healthy individuals and patients. Conclusion: We have provided the first comparison of non-invasive and implanted EMG sensors as input signals for torque estimates in healthy individuals and SCI patients. Significance: Implanted EMG sensors have the potential to be used as a reliable input for assistive exoskeleton joint torque actuation.The authors would like to thank Enrique PĂ©rez Rizo, Natalia Comino SuĂĄrez and MarĂ­a Isabel Sinovas Alonso for their assistance on the experimental and data acquisition procedure
    • 