Use of ambient light in remote photoplethysmographic systems: comparison between a high-performance camera and a low-cost webcam
Imaging photoplethysmography (PPG) is able to capture useful physiological data remotely from a wide range of anatomical locations. Recent imaging PPG studies have concentrated on two broad research directions involving either high-performance cameras and or webcam-based systems. However, little has been reported about the difference between these two techniques, particularly in terms of their performance under illumination with ambient light. We explore these two imaging PPG approaches through the simultaneous measurement of the cardiac pulse acquired from the face of 10 male subjects and the spectral characteristics of ambient light. Measurements are made before and after a period of cycling exercise. The physiological pulse waves extracted from both imaging PPG systems using the smoothed pseudo-Wigner-Ville distribution yield functional characteristics comparable to those acquired using gold standard contact PPG sensors. The influence of ambient light intensity on the physiological information is considered, where results reveal an independent relationship between the ambient
light intensity and the normalized plethysmographic signals. This provides further support for imaging PPG as a means for practical noncontact physiological assessment with clear applications in several domains, including telemedicine and homecare
A novel method of combining blood oxygenation and blood flow sensitive magnetic resonance imaging techniques to measure the cerebral blood flow and oxygen metabolism responses to an unknown neural stimulus.
Simultaneous implementation of magnetic resonance imaging methods for Arterial Spin Labeling (ASL) and Blood Oxygenation Level Dependent (BOLD) imaging makes it possible to quantitatively measure the changes in cerebral blood flow (CBF) and cerebral oxygen metabolism (CMRO(2)) that occur in response to neural stimuli. To date, however, the range of neural stimuli amenable to quantitative analysis is limited to those that may be presented in a simple block or event related design such that measurements may be repeated and averaged to improve precision. Here we examined the feasibility of using the relationship between cerebral blood flow and the BOLD signal to improve dynamic estimates of blood flow fluctuations as well as to estimate metabolic-hemodynamic coupling under conditions where a stimulus pattern is unknown. We found that by combining the information contained in simultaneously acquired BOLD and ASL signals through a method we term BOLD Constrained Perfusion (BCP) estimation, we could significantly improve the precision of our estimates of the hemodynamic response to a visual stimulus and, under the conditions of a calibrated BOLD experiment, accurately determine the ratio of the oxygen metabolic response to the hemodynamic response. Importantly we were able to accomplish this without utilizing a priori knowledge of the temporal nature of the neural stimulus, suggesting that BOLD Constrained Perfusion estimation may make it feasible to quantitatively study the cerebral metabolic and hemodynamic responses to more natural stimuli that cannot be easily repeated or averaged
Recommended from our members
Monitoring of the central blood pressure waveform via a conformal ultrasonic device.
Continuous monitoring of the central-blood-pressure waveform from deeply embedded vessels, such as the carotid artery and jugular vein, has clinical value for the prediction of all-cause cardiovascular mortality. However, existing non-invasive approaches, including photoplethysmography and tonometry, only enable access to the superficial peripheral vasculature. Although current ultrasonic technologies allow non-invasive deep-tissue observation, unstable coupling with the tissue surface resulting from the bulkiness and rigidity of conventional ultrasound probes introduces usability constraints. Here, we describe the design and operation of an ultrasonic device that is conformal to the skin and capable of capturing blood-pressure waveforms at deeply embedded arterial and venous sites. The wearable device is ultrathin (240 μm) and stretchable (with strains up to 60%), and enables the non-invasive, continuous and accurate monitoring of cardiovascular events from multiple body locations, which should facilitate its use in a variety of clinical environments
The Integration of Positron Emission Tomography With Magnetic Resonance Imaging
A number of laboratories and companies are currently exploring the development of integrated imaging systems for magnetic resonance imaging (MRI) and positron emission tomography (PET). Scanners for both preclinical and human research applications are being pursued. In contrast to the widely distributed and now quite mature PET/computed tomography technology, most PET/MRI designs allow for simultaneous rather than sequential acquisition of PET and MRI data. While this offers the possibility of novel imaging strategies, it also creates considerable challenges for acquiring artifact-free images from both modalities. This paper discusses the motivation for developing combined PET/MRI technology, outlines the obstacles in realizing such an integrated instrument, and presents recent progress in the development of both the instrumentation and of novel imaging agents for combined PET/MRI studies. The performance of the first-generation PET/MRI systems is described. Finally, a range of possible biomedical applications for PET/MRI are outlined
Recommended from our members
Dissociation of Cerebral Blood Flow and Femoral Artery Blood Pressure Pulsatility After Cardiac Arrest and Resuscitation in a Rodent Model: Implications for Neurological Recovery.
Background Impaired neurological function affects 85% to 90% of cardiac arrest (CA) survivors. Pulsatile blood flow may play an important role in neurological recovery after CA. Cerebral blood flow (CBF) pulsatility immediately, during, and after CA and resuscitation has not been investigated. We characterized the effects of asphyxial CA on short-term (<2 hours after CA) CBF and femoral arterial blood pressure (ABP) pulsatility and studied their relationship to cerebrovascular resistance (CVR) and short-term neuroelectrical recovery. Methods and Results Male rats underwent asphyxial CA followed by cardiopulmonary resuscitation. A multimodal platform combining laser speckle imaging, ABP, and electroencephalography to monitor CBF, peripheral blood pressure, and brain electrophysiology, respectively, was used. CBF and ABP pulsatility and CVR were assessed during baseline, CA, and multiple time points after resuscitation. Neuroelectrical recovery, a surrogate for neurological outcome, was assessed using quantitative electroencephalography 90 minutes after resuscitation. We found that CBF pulsatility differs significantly from baseline at all experimental time points with sustained deficits during the 2 hours of postresuscitation monitoring, whereas ABP pulsatility was relatively unaffected. Alterations in CBF pulsatility were inversely correlated with changes in CVR, but ABP pulsatility had no association to CVR. Interestingly, despite small changes in ABP pulsatility, higher ABP pulsatility was associated with worse neuroelectrical recovery, whereas CBF pulsatility had no association. Conclusions Our results reveal, for the first time, that CBF pulsatility and CVR are significantly altered in the short-term postresuscitation period after CA. Nevertheless, higher ABP pulsatility appears to be inversely associated with neuroelectrical recovery, possibly caused by impaired cerebral autoregulation and/or more severe global cerebral ischemia
Use of a right ventricular continuous flow pump to validate the distensible model of the pulmonary vasculature
In the pulmonary circulation, resistive and compliant properties overlap in the same vessels. Resistance varies nonlinearly with pressure and flow; this relationship is driven by the elastic properties of the vessels. Linehan et al. (1982) correlated the mean pulmonary arterial pressure and mean flow with resistance using an original equation incorporating the distensibility of the pulmonary arteries. The goal of this study was to validate this equation in an in vivo porcine model. In vivo measurements were acquired in 6 pigs. The distensibility coefficient (DC) was measured by placing piezo-electric crystals around the pulmonary artery (PA). In addition to experiments under pulsatile conditions, a right ventricular (RV) bypass system was used to induce a continuous pulmonary flow state. The Linehan's equation was then used to predict the pressure from the flow under continuous flow conditions. The diameter-derived DC was 2.4 %/mmHg (+/- 0.4 %), whereas the surface area-based DC was 4.1 %/mmHg (+/- 0.1 %). An increase in continuous flow was associated with a constant decrease in resistance, which correlated with the diameter-based DC (r=-0.8407, p=0.044) and the surface area-based DC (r=-0.8986, p=0.028). In contrast to the Linehan's equation, our results showed constant or even decreasing pressure as flow increased. Using a model of continuous pulmonary flow induced by an RV assist system, pulmonary pressure could not be predicted based on the flow using the Linehan's equation. Measurements of distensibility based on the diameter of the PA were inversely correlated with the resistance
Confocal and multiphoton imaging of intracellular Ca<sup>2+</sup>
This chapter compares the imaging capabilities of a range of systems including multiphoton microscopy in regard to measurements of intracellular Ca<sup>2+</sup> within living cells. In particular, the excitation spectra of popular fluorescent Ca<sup>2+</sup> indicators are shown during 1P and 2P excitation. The strengths and limitations of the current indicators are discussed along with error analysis which highlights the value of matching the Ca<sup>2+</sup> affinity of the dye to a particular aspect of Ca<sup>2+</sup> signaling. Finally, the combined emission spectra of Ca<sup>2+</sup> and voltage sensitive dyes are compared to allow the choice of the optimum combination to allow simultaneous intracellular Ca<sup>2+</sup> and membrane voltage measurement
An ultra-fast digital diffuse optical spectroscopic imaging system for neoadjuvant chemotherapy monitoring
Up to 20% of breast cancer patients who undergo presurgical (neoadjuvant) chemotherapy have no response to treatment. Standard-of-care imaging modalities, including MRI, CT, mammography, and ultrasound, measure anatomical features and tumor size that reveal response only after months of treatment. Recently, non-invasive, near-infrared optical markers have shown promise in indicating the efficacy of treatment at the outset of the chemotherapy treatment. For example, frequency domain Diffuse Optical Spectroscopic Imaging (DOSI) can be used to characterize the optical scattering and absorption properties of thick tissue, including breast tumors. These parameters can then be used to calculate tissue concentrations of chromophores, including oxyhemoglobin, deoxyhemoglobin, water, and lipids. Tumors differ in hemoglobin concentration, as compared with healthy background tissue, and changes in hemoglobin concentration during neoadjuvant chemotherapy have been shown to correlate with efficacy of treatment. Using DOSI early in treatment to measure chromophore concentrations may be a powerful tool for guiding neoadjuvant chemotherapy treatment.
Previous frequency-domain DOSI systems have been limited by large device footprints, complex electronics, high costs, and slow acquisition speeds, all of which complicate access to patients in the clinical setting. In this work a new digital DOSI (dDOSI) system has been developed, which is relatively inexpensive and compact, allowing for use at the bedside, while providing unprecedented measurement speeds. The system builds on, and significantly advances, previous dDOSI setups developed by our group and, for the first time, utilizes hardware-integrated custom board-level direct digital synthesizers (DDS) and analog to digital converters (ADC) to generate and directly measure signals utilizing undersampling techniques. The dDOSI system takes high-speed optical measurements by utilizing wavelength multiplexing while sweeping through hundreds of modulation frequencies in tens of milliseconds. The new dDOSI system is fast, inexpensive, and compact without compromising accuracy and precision
Collateral donor artery physiology and the influence of a chronic total occlusion on fractional flow reserve
Background— The presence of a concomitant chronic total coronary occlusion (CTO) and a large collateral contribution might alter the fractional flow reserve (FFR) of an interrogated vessel, rendering the FFR unreliable at predicting ischemia should the CTO vessel be revascularized and potentially affecting the decision on optimal revascularization strategy. We tested the hypothesis that donor vessel FFR would significantly change after percutaneous coronary intervention of a concomitant CTO. Methods and Results— In consecutive patients undergoing percutaneous coronary intervention of a CTO, coronary pressure and flow velocity were measured at baseline and hyperemia in proximal and distal segments of both nontarget vessels, before and after percutaneous coronary intervention. Hemodynamics including FFR, absolute coronary flow, and the coronary flow velocity–pressure gradient relation were calculated. After successful percutaneous coronary intervention in 34 of 46 patients, FFR in the predominant donor vessel increased from 0.782 to 0.810 (difference, 0.028 [0.012 to 0.044]; P=0.001). Mean decrease in baseline donor vessel absolute flow adjusted for rate pressure product: 177.5 to 139.9 mL/min (difference −37.6 [−62.6 to −12.6]; P=0.005), mean decrease in hyperemic flow: 306.5 to 272.9 mL/min (difference, −33.5 [−58.7 to −8.3]; P=0.011). Change in predominant donor vessel FFR correlated with angiographic (%) diameter stenosis severity (r=0.44; P=0.009) and was strongly related to stenosis severity measured by the coronary flow velocity–pressure gradient relation (r=0.69; P<0.001). Conclusions— Recanalization of a CTO results in a modest increase in the FFR of the predominant collateral donor vessel associated with a reduction in coronary flow. A larger increase in FFR is associated with greater coronary stenosis severity
- …