1,074 research outputs found

    Molecular Imaging of Inflammation in Aortic Aneurysmal Disease

    Get PDF
    The high mortality rate of diseases of the aorta has its foundation in imaging methods that define anatomy and disease burden but less so upon the diagnosis of asymptomatic conditions, rate of aneurysm expansion, or prediction of rupture. However, anatomical features can now be co-localized with molecular and physiological activity. The advancement of nanoparticles based upon iron oxide will also serve to bring a trio of magnetic, radionuclide, and optical imaging modalities together. The combinations of these technologies are still at the preclinical refinement stage but already enzyme-activatable probes have b

    A New Image Quantitative Method for Diagnosis and Therapeutic Response

    Get PDF
    abstract: Accurate quantitative information of tumor/lesion volume plays a critical role in diagnosis and treatment assessment. The current clinical practice emphasizes on efficiency, but sacrifices accuracy (bias and precision). In the other hand, many computational algorithms focus on improving the accuracy, but are often time consuming and cumbersome to use. Not to mention that most of them lack validation studies on real clinical data. All of these hinder the translation of these advanced methods from benchside to bedside. In this dissertation, I present a user interactive image application to rapidly extract accurate quantitative information of abnormalities (tumor/lesion) from multi-spectral medical images, such as measuring brain tumor volume from MRI. This is enabled by a GPU level set method, an intelligent algorithm to learn image features from user inputs, and a simple and intuitive graphical user interface with 2D/3D visualization. In addition, a comprehensive workflow is presented to validate image quantitative methods for clinical studies. This application has been evaluated and validated in multiple cases, including quantifying healthy brain white matter volume from MRI and brain lesion volume from CT or MRI. The evaluation studies show that this application has been able to achieve comparable results to the state-of-the-art computer algorithms. More importantly, the retrospective validation study on measuring intracerebral hemorrhage volume from CT scans demonstrates that not only the measurement attributes are superior to the current practice method in terms of bias and precision but also it is achieved without a significant delay in acquisition time. In other words, it could be useful to the clinical trials and clinical practice, especially when intervention and prognostication rely upon accurate baseline lesion volume or upon detecting change in serial lesion volumetric measurements. Obviously, this application is useful to biomedical research areas which desire an accurate quantitative information of anatomies from medical images. In addition, the morphological information is retained also. This is useful to researches which require an accurate delineation of anatomic structures, such as surgery simulation and planning.Dissertation/ThesisDoctoral Dissertation Biomedical Informatics 201

    Near-wall hemodynamic parameters quantification in in vitro intracranial aneurysms with 7 T PC-MRI.

    Get PDF
    OBJECTIVE Wall shear stress (WSS) and its derived spatiotemporal parameters have proven to play a major role on intracranial aneurysms (IAs) growth and rupture. This study aims to demonstrate how ultra-high field (UHF) 7 T phase contrast magnetic resonance imaging (PC-MRI) coupled with advanced image acceleration techniques allows a highly resolved visualization of near-wall hemodynamic parameters patterns in in vitro IAs, paving the way for more robust risk assessment of their growth and rupture. MATERIALS AND METHODS We performed pulsatile flow measurements inside three in vitro models of patient-specific IAs using 7 T PC-MRI. To this end, we built an MRI-compatible test bench, which faithfully reproduced a typical physiological intracranial flow rate in the models. RESULTS The ultra-high field 7 T images revealed WSS patterns with high spatiotemporal resolution. Interestingly, the high oscillatory shear index values were found in the core of low WSS vortical structures and in flow stream intersecting regions. In contrast, maxima of WSS occurred around the impinging jet sites. CONCLUSIONS We showed that the elevated signal-to-noise ratio arising from 7 T PC-MRI enabled to resolve high and low WSS patterns with a high degree of detail
    • …
    corecore