57,825 research outputs found
Self-Calibration Methods for Uncontrolled Environments in Sensor Networks: A Reference Survey
Growing progress in sensor technology has constantly expanded the number and
range of low-cost, small, and portable sensors on the market, increasing the
number and type of physical phenomena that can be measured with wirelessly
connected sensors. Large-scale deployments of wireless sensor networks (WSN)
involving hundreds or thousands of devices and limited budgets often constrain
the choice of sensing hardware, which generally has reduced accuracy,
precision, and reliability. Therefore, it is challenging to achieve good data
quality and maintain error-free measurements during the whole system lifetime.
Self-calibration or recalibration in ad hoc sensor networks to preserve data
quality is essential, yet challenging, for several reasons, such as the
existence of random noise and the absence of suitable general models.
Calibration performed in the field, without accurate and controlled
instrumentation, is said to be in an uncontrolled environment. This paper
provides current and fundamental self-calibration approaches and models for
wireless sensor networks in uncontrolled environments
Real-time sweat pH monitoring based on a wearable chemical barcode micro-fluidic platform incorporating ionic liquids
This work presents the fabrication, characterisation and the performance of a wearable, robust, flexible
and disposable chemical barcode device based on a micro-fluidic platform that incorporates ionic
liquid polymer gels (ionogels). The device has been applied to the monitoring of the pH of sweat in
real time during an exercise period. The device is an ideal wearable sensor for measuring the pH of
sweat since it does not contents any electronic part for fluidic handle or pH detection and because it can
be directly incorporated into clothing, head- or wristbands, which are in continuous contact with the
skin. In addition, due to the micro-fluidic structure, fresh sweat is continuously passing through the sensing area providing the capability to perform continuous real time analysis. The approach presented here ensures immediate feedback regarding sweat composition. Sweat analysis is attractive for monitoring purposes as it can provide physiological information directly relevant to the health and performance of the wearer without the need for an invasive sampling approac
Recommended from our members
Hydrologic evaluation of satellite precipitation products over a mid-size basin
Since the past three decades a great deal of effort is devoted to development of satellite-based precipitation retrieval algorithms. More recently, several satellite-based precipitation products have emerged that provide uninterrupted precipitation time series with quasi-global coverage. These satellite-based precipitation products provide an unprecedented opportunity for hydrometeorological applications and climate studies. Although growing, the application of satellite data for hydrological applications is still very limited. In this study, the effectiveness of using satellite-based precipitation products for streamflow simulation at catchment scale is evaluated. Five satellite-based precipitation products (TMPA-RT, TMPA-V6, CMORPH, PERSIANN, and PERSIANN-adj) are used as forcing data for streamflow simulations at 6-h and monthly time scales during the period of 2003-2008. SACramento Soil Moisture Accounting (SAC-SMA) model is used for streamflow simulation over the mid-size Illinois River basin.The results show that by employing the satellite-based precipitation forcing the general streamflow pattern is well captured at both 6-h and monthly time scales. However, satellites products, with no bias-adjustment being employed, significantly overestimate both precipitation inputs and simulated streamflows over warm months (spring and summer months). For cold season, on the other hand, the unadjusted precipitation products result in under-estimation of streamflow forecast. It was found that bias-adjustment of precipitation is critical and can yield to substantial improvement in capturing both streamflow pattern and magnitude. The results suggest that along with efforts to improve satellite-based precipitation estimation techniques, it is important to develop more effective near real-time precipitation bias adjustment techniques for hydrologic applications. © 2010 Elsevier B.V
Dial It In: Rotating RF Sensors to Enhance Radio Tomography
A radio tomographic imaging (RTI) system uses the received signal strength
(RSS) measured by RF sensors in a static wireless network to localize people in
the deployment area, without having them to carry or wear an electronic device.
This paper addresses the fact that small-scale changes in the position and
orientation of the antenna of each RF sensor can dramatically affect imaging
and localization performance of an RTI system. However, the best placement for
a sensor is unknown at the time of deployment. Improving performance in a
deployed RTI system requires the deployer to iteratively "guess-and-retest",
i.e., pick a sensor to move and then re-run a calibration experiment to
determine if the localization performance had improved or degraded. We present
an RTI system of servo-nodes, RF sensors equipped with servo motors which
autonomously "dial it in", i.e., change position and orientation to optimize
the RSS on links of the network. By doing so, the localization accuracy of the
RTI system is quickly improved, without requiring any calibration experiment
from the deployer. Experiments conducted in three indoor environments
demonstrate that the servo-nodes system reduces localization error on average
by 32% compared to a standard RTI system composed of static RF sensors.Comment: 9 page
Characterization of the on-body path Loss at 2.45 GHz and energy efficient WBAN design for dairy cows
Wireless body area networks (WBANs) provide promising applications in the healthcare monitoring of dairy cows. The characterization of the path loss (PL) between on-body nodes constitutes an important step in the deployment of a WBAN. In this paper, the PL between nodes placed on the body of a dairy cow was determined at 2.45 GHz. Finite-difference time domain simulations with two half-wavelength dipoles placed 20 mm above a cow model were performed using a 3-D electromagnetic solver. Measurements were conducted on a live cow to validate the simulation results. Excellent agreement between measurements and simulations was achieved and the obtained PL values as a function of the transmitter-receiver separation were well fitted by a lognormal PL model with a PL exponent of 3.1 and a PL at reference distance ( 10 cm) of 44 dB. As an application, the packet error rate ( PER) and the energy efficiency of different WBAN topologies for dairy cows (i.e., single-hop, multihop, and cooperative networks) were investigated. The analysis results revealed that exploiting multihop and cooperative communication schemes decrease the PER and increase the optimal payload packet size. The analysis results revealed that exploiting multihop and cooperative communication schemes increase the optimal payload packet size and improve the energy efficiency by 30%
Drift Correction Methods for gas Chemical Sensors in Artificial Olfaction Systems: Techniques and Challenges
In this chapter the authors introduce the main challenges faced when developing drift correction techniques and will propose a deep overview of state-of-the-art methodologies that have been proposed in the scientific literature trying to underlying pros and cons of these techniques and focusing on challenges still open and waiting for solution
Recommended from our members
A review of machine learning techniques in photoplethysmography for the non-invasive cuff-less measurement of blood pressure
Hypertension or high blood pressure is a leading cause of death throughout the world and a critical factor for increasing the risk of serious diseases, including cardiovascular diseases such as stroke and heart failure. Blood pressure is a primary vital sign that must be monitored regularly for the early detection, prevention and treatment of cardiovascular diseases. Traditional blood pressure measurement techniques are either invasive or cuff-based, which are impractical, intermittent, and uncomfortable for patients. Over the past few decades, several indirect approaches using photoplethysmogram (PPG) have been investigated, namely, pulse transit time, pulse wave velocity, pulse arrival time and pulse wave analysis, in an effort to utilise PPG for estimating blood pressure. Recent advancements in signal processing techniques, including machine learning and artificial intelligence, have also opened up exciting new horizons for PPG-based cuff less and continuous monitoring of blood pressure. Such a device will have a significant and transformative impact in monitoring patients’ vital signs, especially those at risk of cardiovascular disease. This paper provides a comprehensive review for non-invasive cuff-less blood pressure estimation using the PPG approach along with their challenges and limitations
- …