    Reduction of Current Harmonic Distortion in Three-Phase Grid-Connected Photovoltaic Inverters via Resonant Current Control

    Get PDF
    The resonant current control has been extensively employed to reduce the current harmonic distortion in a wide range of grid-connected distributed generation applications, including photovoltaic (PV) inverters, wind and water turbines, and fuel-cell inverters. However, the performance of these systems is deteriorated when the utility grid voltage experiences abnormal conditions such as voltage harmonics and imbalances. Several advanced control solutions have been recently introduced to cope with this problem but at the cost of a significant increase in the control computational load. This paper first analyzes the limitations of the standard resonant current control operating under abnormal grid conditions and then introduces a control scheme that improves the current harmonic distortion in such adverse conditions without increasing the computational load of the standard current control. This theoretical contribution is validated by means of selected experimental results from a three-phase PV inverterPostprint (published version

    Low order harmonic cancellation in a grid connected multiple inverter system via current control parameter randomization

    Get PDF
    In grid connected multiple inverter systems, it is normal to synchronize the output current of each inverter to the common network voltage. Any current controller deficiencies, which result in low order harmonics, are also synchronized to the common network voltage. As a result the harmonics produced by individual converters show a high degree of correlation and tend to be additive. Each controller can be tuned to achieve a different harmonic profile so that harmonic cancellation can take place in the overall system, thus reducing the net current total harmonic distortion level. However, inter-inverter communication is required. This paper presents experimental results demonstrating an alternative approach, which is to arrange for the tuning within each inverter to be adjusted automatically with a random component. This results in a harmonic output spectrum that varies with time, but is uncorrelated with the harmonic spectrum of any other inverter in the system. The net harmonics from all the inverters undergo a degree of cancellation and the overall system yields a net improvement in power quality

    Low order harmonics mitigation in grid connected, parallel PV inverters

    Get PDF
    PhD ThesisThis research is concerned with the problem of network power quality when grid connected systems are used to feed the network distribution grid. A parallel connection of photovoltaic (PV) system is the main interest of study for this research. This type of PV system uses power electronic components such as inverter and current controller that produce harmonics which adversely affect the power quality of the distribution network. Development and simulation of current controller using the proportional resonance (PR) scheme is considered to overcome the harmonic problems in single and parallel PV inverters. This scheme eliminates specific harmonic in the low order part. The control parameter randomisation technique is added to the scheme to produce a more efficient current controller system. Thus, the inverter harmonic performance (inverter output current) is improved. This concept is extended to parallel inverter based systems, where opportunities for harmonic cancellation improve the inverter harmonic performance further. Experimental hardware setup using TMS320F2812 is also developed to verify the promising simulation results

    Power quality and electromagnetic compatibility: special report, session 2

    Get PDF
    The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems. Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages). The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks: Block 1: Electric and Magnetic Fields, EMC, Earthing systems Block 2: Harmonics Block 3: Voltage Variation Block 4: Power Quality Monitoring Two Round Tables will be organised: - Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13) - Reliability Benchmarking - why we should do it? What should be done in future? (RT 15

    Review of Harmonic Mitigation Methods in Microgrid: From a Hierarchical Control Perspective

    Get PDF

    Mitigation of DC Current Injection in Transformerless Grid-Connected Inverters

    Get PDF
    PhD ThesisWith a large number of small-scale PV plants being connected to the utility grid, there is increasing interest in the use of transformerless systems for grid-connected inverter photovoltaic applications. Compared to transformer-coupled solutions, transformerless systems offer a typical efficiency increase of 1-2%, reduced system size and weight, and reductions in cost. However, the removal of the transformer has technical implications. In addition to the loss of galvanic isolation, DC current injection into the grid is a potential risk. Whilst desirable, the complete mitigation of DC current injection via conventional current control methods is known to be particularly challenging, and there are remaining implementation issues in previous studies. For this reason, this thesis aims to minimize DC current injection in grid-connected transformerless PV inverter systems. The first part of the thesis reviews the technical challenges and implementation issues in published DC measurement techniques and suppression methods. Given mathematical models, the performance of conventional current controllers in terms of DC and harmonics mitigation is analyzed and further confirmed in simulations and experiments under different operating conditions. As a result, the second part of the thesis introduces two DC suppression methods, a DC voltage mitigation approach and a DC link current sensing technique. The former method uses a combination of a passive attenuation circuit and a software filter stage to extract the DC voltage component, which allows for further digital control and DC component mitigation at the inverter output. It is proven to be a simple and highly effective solution, applicable for any grid-connected PV inverter systems. The DC link sensing study then investigates a control-based solution in which the dc injection is firstly accurately determined via extraction of the line frequency component from the DC link current and then mitigated with a closed loop. With an output current reconstruction process, this technique provides robust current control and effective DC suppression based on DC link current measurement, eliminating the need for the conventional output current sensor. Results from rated simulation models and a laboratory grid-connected inverter system are presented to demonstrate the accurate and robust performance of the proposed techniques. This thesis makes a positive contribution in the area of power quality control in grid-connected inverters, specifically mitigating the impact of DC injection into the grid which has influences on the network operating conditions and the design and manufacture of the PV power converter itsel

    A multifunctional dynamic voltage restorer for power quality improvement

    Get PDF
    Power quality is a major concern in electrical power systems. The power quality disturbances such as sags, swells, harmonic distortion and other interruptions have an impact on the electrical devices and machines and in severe cases can cause serious damages. Therefore it is necessary to recognize and compensate all types of disturbances at an earliest time to ensure normal and efficient operation of the power system. To solve these problems, many types of power devices are used. At the present time, one of those devices, Dynamic Voltage Restorer (DVR) is the most efficient and effective device used in power distribution systems. In this paper, design and modeling of a new structure and a new control method of multifunctional DVRs for voltage quality correction are presented. The new control method was built in the stationary frame by combining Proportional Resonant controllers and Sequence-Decouple Resonant controllers. The performance of the device and this method under different conditions such as voltage swell, voltage sag due to symmetrical and unsymmetrical short circuit, starting of motors, and voltage distortion are described. Simulation result show the superior capability of the proposed DVR to improve power quality under different operating conditions and the effectiveness of the proposed method. The proposed new DVR controller is able to detect the voltage disturbances and control the converter to inject appropriate voltages independently for each phase and compensate to load voltage through three single-phase transformers.Web of Science116art. no. 135