1,530 research outputs found

    The Essential Role and the Continuous Evolution of Modulation Techniques for Voltage-Source Inverters in the Past, Present, and Future Power Electronics

    Get PDF
    The cost reduction of power-electronic devices, the increase in their reliability, efficiency, and power capability, and lower development times, together with more demanding application requirements, has driven the development of several new inverter topologies recently introduced in the industry, particularly medium-voltage converters. New more complex inverter topologies and new application fields come along with additional control challenges, such as voltage imbalances, power-quality issues, higher efficiency needs, and fault-tolerant operation, which necessarily requires the parallel development of modulation schemes. Therefore, recently, there have been significant advances in the field of modulation of dc/ac converters, which conceptually has been dominated during the last several decades almost exclusively by classic pulse-width modulation (PWM) methods. This paper aims to concentrate and discuss the latest developments on this exciting technology, to provide insight on where the state-of-the-art stands today, and analyze the trends and challenges driving its future

    Online control of AC/AC converter based SHEPWM technique

    Get PDF
    Conventional online control of AC/AC converter controlled by the selective harmonic elimination pulse width modulation technique (SHEPWM) is based on storing the offline calculated switching angle values in a form of lookup table. Then the required switching pattern of certain modulation index (M) is searched through the lookup table. This methodology suffers from limited system flexibility. This paper introduces a novel implementation scheme based on real-time calculation of the required SHEPWM switching pattern with linear control of the fundamental voltage component magnitude based on curve fitting technique for the exact switching angle trajectories. The accuracy of the derived polynomials is evaluated by calculating converter performance parameters using the approximated switching angles solutions obtained from the introduced method and the exact switching angles solutions. Detail of the introduced methodology is presented. Simulation and experimental results have been carried out to confirm the validity of the introduced algorithm

    Fuzzy Controller for Matrix Converter System to Improve its Quality of Output

    Full text link
    In this paper, Fuzzy Logic controller is developed for ac/ac Matrix Converter. Furthermore, Total Harmonic Distortion is reduced significantly. Space Vector Algorithm is a method to improve power quality of the converter output. But its quality is limited to 86.7%.We are introduced a Cross coupled DQ axis controller to improve power quality. The Matrix Converter is an attractive topology for High voltage transformation ratio. A Matlab / Simulink simulation analysis of the Matrix Converter system is provided. The design and implementation of fuzzy controlled Matrix Converter is described. This AC-AC system is proposed as an effective replacement for the conventional AC-DC-AC system which employs a two-step power conversion.Comment: 11 page

    Multilevel Converters: An Enabling Technology for High-Power Applications

    Get PDF
    | Multilevel converters are considered today as the state-of-the-art power-conversion systems for high-power and power-quality demanding applications. This paper presents a tutorial on this technology, covering the operating principle and the different power circuit topologies, modulation methods, technical issues and industry applications. Special attention is given to established technology already found in industry with more in-depth and self-contained information, while recent advances and state-of-the-art contributions are addressed with useful references. This paper serves as an introduction to the subject for the not-familiarized reader, as well as an update or reference for academics and practicing engineers working in the field of industrial and power electronics.Ministerio de Ciencia y Tecnología DPI2001-3089Ministerio de Eduación y Ciencia d TEC2006-0386

    Implementation of a Digital Signal Processor (DSP) Based Space Vector Control of AC Induction Motor Drives

    Get PDF
    The inverters transfer energy from a DC source to a controlled process in the form of pulse trains, using semiconductor switches which are turned on and off at fast repetition rates. This thesis explains in depth how these pulse trains synthesize sine waves. AC waveform generation techniques such as the square wave and Pulse Width Modulation (PWM) are compared in terms of their harmonic elimination capability and fundamental gain control. Various PWM techniques such as bipolar switching, unipolar switching, selective harmonic elimination switching and Space Vector PWM (SVPWM) switching are analyzed and compared in terms of their ability to control harmonic distortion (THD), minimize switching losses, control fundamental gain and maximize DC bus utilization capacity. The selective harmonic elimination technique is covered in depth including a technique that utilizes a neural network controller to remove a selected set of harmonics. This thesis focuses on Space Vector PWM (SVPWM) technique since it has many advantages over other conventional methods such as sine wave PWM. Thus, the SVPWM theory and experimental analysis is presented in depth. The SVPWM technique was realized using the state-of-the- art power electronics hardware and Digital Signal Processing (DSP) software. The experimental procedure and harmonics analysis of the DSP based SVPWM output waveforms and inverter output voltages and currents are presented. The experiments were carried out using power electronics development modules such as the Texas Instrument’s TMS320LF2407 DSK (eZdsp), Digital Motor Controller (DMC1500), and the VisSim™/TI C2000 Rapid Prototyper software package and a three-phase AC induction motor. The VisSim™/TI C2000 Rapid Prototyper was extensively used to model an AC induction motor control sub system that generates real time SVPWM waveforms to control a three-phase induction motor. The AC induction motor control sub-system was implemented using the principle of constant Volts/Hertz (V/Hz) profile. S\u27 averal measurements and observations of the phase-voltages, line-voltages and phase currents were made to observe the quality of the power produced using the SVPWM technique. The SVPWM waveforms were simulated using MATi_AB™ software and the VisSim™/TI C2000 Rapid Protctyper software. These simulated SVPWM waveforms were compared with the DSP generated SVPWM waveforms and the inverter output. The completed project will give the user the ability to use the VisSim™/TI C2000 Rapid Prototyper software to generate SVPWM waveform and power the DSP controller (eZdsp), interface the DMC1500 (inverter) with the eZdsp and control a three-phase induction motor. An extension of the conventional three-phase SVPWM to higher order phase systems is reviewed. An overview of the principle of sensorless variable speed three-phase AC motor drives with closed-loop speed control is included

    Control Strategies for Open-End Winding Drives Operating in the Flux-Weakening Region

    Get PDF
    This paper presents and compares control strategies for three-phase open-end winding drives operating in the flux-weakening region. A six-leg inverter with a single dc-link is associated with the machine in order to use a single energy source. With this topology, the zero-sequence circuit has to be considered since the zero-sequence current can circulate in the windings. Therefore, conventional over-modulation strategies are not appropriate when the machine enters in the flux-weakening region. A few solutions dealing with the zero-sequence circuit have been proposed in literature. They use a modified space vector modulation or a conventional modulation with additional voltage limitations. The paper describes the aforementioned strategies and then a new strategy is proposed. This new strategy takes into account the magnitudes and phase angles of the voltage harmonic components. This yields better voltage utilization in the dq frame. Furthermore, inverter saturation is avoided in the zero-sequence frame and therefore zero-sequence current control is maintained. Three methods are implemented on a test bed composed of a three-phase permanent-magnet synchronous machine, a six-leg inverter and a hybrid DSP/FPGA controller. Experimental results are presented and compared for all strategies. A performance analysis is conducted as regards the region of operation and the machine parameters.Projet SOFRACI/FU

    New optimal PWM strategies for a VSI induction motor drive

    Get PDF
    The applications of robust squirrel-cage induction motors in variable speed inverter drive systems have increased considerably due to the availability of easily controlled semiconductor switching devices. One problem encountered in inverter drives is the non-sinusoidal nature of the supply voltage, which results in increased motor losses and harmful torque pulsations producing undesirable speed oscillations. The latter effects are negligible at high frequency operation, due to the damping effect of the rotor and load inertia. However, torque pulsations and speed ripple may be appreciable at low frequency, wore they may result in abnormal wear of gear-teeth or torsional shaft failure. Hence, in applications where constant or precise speed control is important, eg; machine tool, antenna positioning, traction drives etc., it is essential to establish a method for determining the magnitudes of these torque pulsations and speed ripple, as a first stage in minimizing or eliminating them. When a voltage source inverter is used in such applications, pulse width modulation (PWM) techniques are usually employed, whereby the quasi square waveshape is modulated so as to minimize or eliminate the low order harmonic voltage components and thereby reduce the torque pulsations. Recent investigations have shown that total elimination of low order components does not produce optimal efficiency or torque pulsations and speed ripple. minimization. This thesis describes new PWM strategies which does not rely on complete elimination of low order harmonics, but on controlling the magnitude and phase of these components to achieve a smooth rotor motion. Initially, a mathematical model for the inverter/induction motor drive was developed, based on numerical integration of the system differential equations. The changing topology of the inverter bridge was simulated using tensor techniques. Then an analytical method, based on harmonic equivalent circuit analysis was proposed for calculating the induction motor pulsating torque components under steady-state operating conditions, in terms of stator and rotor current harmonics. The accuracy of this method was verified by comparing its results with those obtained from the mathematical model developed earlier. This provided an extremely rapid, numerically stable and efficient means for evaluating harmonic current and torque components with balanced non-sinusoidal applied voltages. This method was then used to formulate the torque performance function necessary to determine the new optimal PWM switching strategies. Throughout the work, the predicted performance was extensively validated and supported by practical results obtained from an experimental rig specifically designed to drive the machine under different PWM techniques

    Direct usage of photovoltaic solar panels to supply a freezer motor with variable DC input voltage

    Get PDF
    In this paper, a single-phase photovoltaic (PV) inverter fed by a boost converter to supply a freezer motor with variable DC input is investigated. The proposed circuit has two stages. Firstly, the DC output of the PV panel that varies between 150 and 300 V will be applied to the boost converter. The boost converter will boost the input voltage to a fixed 300 V DC. Next, this voltage is supplied to the single-phase full-bridge inverter to obtain 230 V AC. In the end, The output of the inverter will feed a freezer motor. The PV panels can be stand-alone or grid-connected. The grid-connected PV is divided into two categories, such as with a transformer and without a transformer, a transformer type has galvanic isolation resulting in increasing the security and also provides no further DC current toward the grid, but it is expensive, heavy and bulky. The transformerless type holds high efficiency and it is cheaper, but it suffers from leakage current between PV and the grid. This paper proposes a stand-alone direct use of PV to supply a freezer; therefore, no grid connection will result in no leakage current between the PV and Grid. The proposed circuit has some features such as no filtering circuit at the output of the inverter, no battery in the system, DC-link instead of AC link that reduces no-loads, having a higher efficiency, and holding enough energy in the DC-link capacitor to get the motor started. The circuit uses no transformers, thus, it is cheaper and has a smaller size. In addition, the system does not require a complex pulse width modulation (PWM) technique, because the motor can operate with a pulsed waveform. The control strategy uses the PWM signal with the desired timing. With this type of square wave, the harmonics (5th and 7th) of the voltage are reduced. The experimental and simulation results are presented to verify the feasibility of the proposed strategy

    Non-intrusive efficiency estimation of inverter-fed induction machines

    Get PDF
    Motorised loads using induction machines use approximately 60% of the electricity globally. Most of these systems use three-phase induction motors due to their robustness and lower cost. They are often installed in continuously operating industrial plants/applications that require no operational interruptions. Whilst most of these induction machines are supplied from ideally sinusoidal supplies, applications are emerging where induction machines are fed from non-sinusoidal supplies. In particular, pulse width modulated inverters realize efficient control of induction machines in many automated industrial applications. From an energy management perspective, it is vital to continually assess the efficiency of induction machines in order to initiate replacement or economic repair. It is therefore of paramount importance that reliable and non-intrusive techniques for efficiency estimation of induction machines be investigated, that consider sinusoidal and non-sinusoidal supplies. This work proposes a non-intrusive efficiency estimation technique for inverter–fed induction motors that is based on harmonic regression analysis, harmonic equivalent circuit parameter estimation and harmonic loss analysis using limited measured data. Firstly, considerations for inverter-fed induction motor equivalent circuit modelling and parameter estimation techniques suitable for non-intrusive efficiency estimation are presented and the selection of one equivalent circuit for analysis is justified. Measured data is obtained from two different induction motors on a flexible 110kW test rig that utilises an HBM Gen 7i data acquisition system. By measuring voltage, current and input power at the supply terminals of the inverter-fed motor, the fundamental equivalent circuit parameters are estimated using population based incremental learning algorithm and compared with those obtained from the IEC 60034-2-1 Standard. The harmonic parameters are estimated using the bacterial foraging algorithm basing on the input impedance of the motor at each harmonic order. A finite harmonic loss analysis is carried out on the tested induction motors. The proposed techniques and harmonic loss analysis provide accurate efficiency estimates of within 1.5% error when compared to the direct method. Lastly, a related non-intrusive efficiency estimation technique is proposed that caters for a holistic loss contribution by all harmonics. The efficiency results from the proposed techniques are compared to those obtained from the IEC-TS 60034-2-3 Technical Specification and a direct method. The estimated efficiencies are comparable to those measured by the Technical Specification and a direct method within 2% error when tested on 37kW and 45kW PWM inverter-fed motors across the loading range. Furthermore, this work conducts a comprehensive non-intrusive rotor speed estimation comparative analysis in order to recommend the best technique(s), in terms of intrusiveness, accuracy and computational overhead. Errors of less than 1% have been reported in literature and experimental verification when using vibration analysis, Motor Current Signature Analysis (MCSA), Rotor Slot Harmonic (RSH) and Rotor Eccentricity Harmonic (REH) analysis techniques in inverter-fed IMs
    corecore