4,411 research outputs found

    Debatable issues in automated ECG reporting

    Get PDF
    Although automated ECG analysis has been available for many years, there are some aspects which require to be re-assessed with respect to their value while newer techniques which are worthy of review are beginning to find their way into routine use. At the annual International Society of Computerized Electrocardiology conference held in April 2017, four areas in particular were debated. These were a) automated 12 lead resting ECG analysis; b) real time out of hospital ECG monitoring; c) ECG imaging; and d) single channel ECG rhythm interpretation. One speaker presented the positive aspects of each technique and another outlined the more negative aspects. Debate ensued. There were many positives set out for each technique but equally, more negative features were not in short supply, particularly for out of hospital ECG monitoring

    Assessment of the feasibility of an ultra-low power, wireless digital patch for the continuous ambulatory monitoring of vital signs.

    Get PDF
    BACKGROUND AND OBJECTIVES: Vital signs are usually recorded at 4–8 h intervals in hospital patients, and deterioration between measurements can have serious consequences. The primary study objective was to assess agreement between a new ultra-low power, wireless and wearable surveillance system for continuous ambulatory monitoring of vital signs and a widely used clinical vital signs monitor. The secondary objective was to examine the system's ability to automatically identify and reject invalid physiological data. SETTING: Single hospital centre. PARTICIPANTS: Heart and respiratory rate were recorded over 2 h in 20 patients undergoing elective surgery and a second group of 41 patients with comorbid conditions, in the general ward. OUTCOME MEASURES: Primary outcome measures were limits of agreement and bias. The secondary outcome measure was proportion of data rejected. RESULTS: The digital patch provided reliable heart rate values in the majority of patients (about 80%) with normal sinus rhythm, and in the presence of abnormal ECG recordings (excluding aperiodic arrhythmias such as atrial fibrillation). The mean difference between systems was less than ±1 bpm in all patient groups studied. Although respiratory data were more frequently rejected as invalid because of the high sensitivity of impedance pneumography to motion artefacts, valid rates were reported for 50% of recordings with a mean difference of less than ±1 brpm compared with the bedside monitor. Correlation between systems was statistically significant (p<0.0001) for heart and respiratory rate, apart from respiratory rate in patients with atrial fibrillation (p=0.02). CONCLUSIONS: Overall agreement between digital patch and clinical monitor was satisfactory, as was the efficacy of the system for automatic rejection of invalid data. Wireless monitoring technologies, such as the one tested, may offer clinical value when implemented as part of wider hospital systems that integrate and support existing clinical protocols and workflows

    Electrocardiographic patch devices and contemporary wireless cardiac monitoring.

    Get PDF
    Cardiac electrophysiologic derangements often coexist with disorders of the circulatory system. Capturing and diagnosing arrhythmias and conduction system disease may lead to a change in diagnosis, clinical management and patient outcomes. Standard 12-lead electrocardiogram (ECG), Holter monitors and event recorders have served as useful diagnostic tools over the last few decades. However, their shortcomings are only recently being addressed by emerging technologies. With advances in device miniaturization and wireless technologies, and changing consumer expectations, wearable “on-body” ECG patch devices have evolved to meet contemporary needs. These devices are unobtrusive and easy to use, leading to increased device wear time and diagnostic yield. While becoming the standard for detecting arrhythmias and conduction system disorders in the outpatient setting where continuous ECG monitoring in the short to medium term (days to weeks) is indicated, these cardiac devices and related digital mobile health technologies are reshaping the clinician-patient interface with important implications for future healthcare delivery

    Design and evaluation of a person-centric heart monitoring system over fog computing infrastructure

    Get PDF
    Heart disease and stroke are becoming the leading cause of death worldwide. Electrocardiography monitoring devices (ECG) are the only tool that helps physicians diagnose cardiac abnormalities. Although the design of ECGs has followed closely the electronics miniaturization evolution over the years, existing wearable ECG have limited accuracy and rely on external resources to analyze the signal and evaluate heart activity. In this paper, we work towards empowering the wearable device with processing capabilities to locally analyze the signal and identify abnormal behavior. The ability to differentiate between normal and abnormal heart activity significantly reduces (a) the need to store the signals, (b) the data transmitted to the cloud and (c) the overall power consumption. Based on this concept, the HEART platform is presented that combines wearable embedded devices, mobile edge devices, and cloud services to provide on-the-spot, reliable, accurate and instant monitoring of the heart. The performance of the system is evaluated concerning the accuracy of detecting abnormal events and the power consumption of the wearable device. Results indicate that a very high percentage of success can be achieved in terms of event detection ratio and the device being operative up to a several days without the need for a recharge

    Automatic Mode Switching in Atrial Fibrillation

    Get PDF
    Automatic mode switching (AMS) algorithms were designed to prevent tracking of atrial tachyarrhythmias (ATA) or other rapidly occurring signals sensed by atrial channels, thereby reducing the adverse hemodynamic and symptomatic consequences of a rapid ventricular response. The inclusion of an AMS function in most dual chamber pacemaker now provides optimal management of atrial arrhythmias and allows the benefit of atrioventricular synchrony to be extended to a population with existing atrial fibrillation. Appropriate AMS depends on several parameters: a) the programmed parameters; b) the characteristics of the arrhythmia; c) the characteristics of the AMS algorithm. Three qualifying aspects constitute an AMS algorithm: onset, AMS response, and resynchronization. Since AMS programs also provide data on the time of onset and duration of AMS episodes, AMS data may be interpreted as a surrogate marker of ATAs recurrence. Recently, stored electrograms corresponding to episodes of ATAs have been introduced, thus clarifying the accuracy of AMS in detecting ATAs Clinically this information may be used to assess the efficacy of an antiarrhythmic intervention or the risk of thromboembolic events, and it may serve as a valuable research tool for evaluating the natural history and burden of ATAs
    • …