    The Design of Digital Heart Rate Meter Using Microcontroller

    Get PDF
    Cardiac tests generally use an electrocardiograph, the results of which are used by medical teams to diagnose heart conditions. Individual ECG examination is held in a health care institution so that it cannot be held independently, considering the high costs and the need for analysis by a specialist.  It is, therefore, necessary to have a functional and portable device to detect heart rate. The heart rate measuring device, equipped with a finger sensor, was designed for adults. The 15-second measurement interval showed the heart rate in one minute and the results were shown on an LCD. The minimum system circuit used ATMega 16

    A Photoplethysmography System Optimised for Pervasive Cardiac Monitoring

    No full text
    Photoplethysmography is a non-invasive sensing technique which infers instantaneous cardiac function from an optical measurement of blood vessels. This thesis presents a photoplethysmography based sensor system that has been developed speci fically for the requirements of a pervasive healthcare monitoring system. Continuous monitoring of patients requires both the size and power consumption of the chosen sensor solution to be minimised to ensure the patients will be willing to use the device. Pervasive sensing also requires that the device be scalable for manufacturing in high volume at a build cost that healthcare providers are willing to accept. System level choice of both electronic circuits and signal processing techniques are based on their sensitivity to cardiac biosignals, robustness against noise inducing artefacts and simplicity of implementation. Numerical analysis is used to justify the implementation of a technique in hardware. Circuit prototyping and experimental data collection is used to validate a technique's application. The entire signal chain operates in the discrete-time domain which allows all of the signal processing to be implemented in firmware on an embedded processor which minimised the number of discrete components while optimising the trade-off between power and bandwidth in the analogue front-end. Synchronisation of the optical illumination and detection modules enables high dynamic range rejection of both AC and DC independent light sources without compromising the biosignal. Signal delineation is used to reduce the required communication bandwidth as it preserves both amplitude and temporal resolution of the non-stationary photoplethysmography signals allowing more complicated analytical techniques to be performed at the other end of communication channel. The complete sensing system is implemented on a single PCB using only commercial-off -the-shelf components and consumes less than 7.5mW of power. The sensor platform is validated by the successful capture of physiological data in a harsh optical sensing environment

    A Photoplethysmography System Optimised for Pervasive Cardiac Monitoring

    Get PDF
    Photoplethysmography is a non-invasive sensing technique which infers instantaneous cardiac function from an optical measurement of blood vessels. This thesis presents a photoplethysmography based sensor system that has been developed speci fically for the requirements of a pervasive healthcare monitoring system. Continuous monitoring of patients requires both the size and power consumption of the chosen sensor solution to be minimised to ensure the patients will be willing to use the device. Pervasive sensing also requires that the device be scalable for manufacturing in high volume at a build cost that healthcare providers are willing to accept. System level choice of both electronic circuits and signal processing techniques are based on their sensitivity to cardiac biosignals, robustness against noise inducing artefacts and simplicity of implementation. Numerical analysis is used to justify the implementation of a technique in hardware. Circuit prototyping and experimental data collection is used to validate a technique's application. The entire signal chain operates in the discrete-time domain which allows all of the signal processing to be implemented in firmware on an embedded processor which minimised the number of discrete components while optimising the trade-off between power and bandwidth in the analogue front-end. Synchronisation of the optical illumination and detection modules enables high dynamic range rejection of both AC and DC independent light sources without compromising the biosignal. Signal delineation is used to reduce the required communication bandwidth as it preserves both amplitude and temporal resolution of the non-stationary photoplethysmography signals allowing more complicated analytical techniques to be performed at the other end of communication channel. The complete sensing system is implemented on a single PCB using only commercial-off -the-shelf components and consumes less than 7.5mW of power. The sensor platform is validated by the successful capture of physiological data in a harsh optical sensing environment

    Reduction of Periodic Motion Artifacts in Photoplethysmography

    Full text link

    Increasing Signal to Noise Ratio and Minimising Artefacts in Biomedical Instrumentation Systems

    Get PDF
    The research work described in this thesis was concerned with finding a novel method of minimising motion artefacts in biomedical instrumentation systems. The proposed solution, an Analog Frontend (AFE), was designed to detect any vertical (Y-Plane) or horizontal (X-Plane) movement of the electrode using two strain gauges, which were separated by 90° and fitted onto the electrode. The detected motion was fed back to the system for the removal of any motion artefact. The research started by emphasising the importance of minimising motion artefacts from biomedical signals and explaining how important it is for a clinical misinterpretation of the results. Hence, various motion artefact minimisation techniques undertaken by other researchers in the field were reviewed. This study covered different sources of artefacts, including the 40kHz powerline interference (PLI), 50/60kHz common-mode noise, white noise, and motion artefacts. The system was fully developed and tested and was firstly simulated using MATLAB Simulink tools to prove the effectiveness of the system before starting the implementation and build phase in the lab. The AFE system successfully produced a clean output signal, achieving an average correlation coefficient of 0.995. Also, the system output had a 98% SNR similarity with the clean source signal. Further, the system was then built and tested in the lab and successfully minimised the motion artefacts, achieving an average correlation coefficient of 0.974. Additionally, the final output had a 97.8% SNR similarity with the clean source signal. A novel test rig was developed to test the system with strain gauges. The system was able to remove the detected signal from the test rig and had an average correlation coefficient of 0.957. Lastly, the final output had a 94.2% SNR similarity with the clean source signal

    Evaluation of Wearable Optical Heart Rate Monitoring Sensors

    Get PDF
    Heart rate monitoring provides valuable information about an individual’s physiological condition. The information obtained from heart rate monitoring can be used for a wide range of purposes such as clinical diagnostics, assessment of the efficiency of training for sports and fitness, or of sleep quality and stress levels in wellbeing applications. Other useful parameters for describing a person’s fitness, such as maximal oxygen uptake and energy expenditure, can also be estimated using heart rate measurement. The traditional ‘gold standard’ for heart rate monitoring is the electrocardiograph, but nowadays there are a number of alternative methods too. Of these, optical sensors provide a relatively simple, lowcost and unobtrusive technology for monitoring heart rate and they are widely accepted by users. There are many factors affecting the measurement of optical signals that have an effect on the accuracy of heart rate estimation. However, there is a lack of standardized and unified methodology for comparing the accuracy of optical heart rate sensors to the ‘gold standard’ methods of measuring heart rate. The widespread use of optical sensors for different purposes has led to a pressing need for a common objective methodology for the evaluation of how accurate these sensors are. This thesis presents a methodology for the objective evaluation of optical heart-rate sensors. The methodology is applied in evaluation studies of four commercially available optical sensors. These evaluations were carried out during both controlled and non-controlled sporting and daily life activities. In addition, evaluation of beat detection accuracy was carried out in non-controlled sleep conditions. The accuracy of wrist-worn optical heart-rate sensors in estimating of maximal oxygen uptake during submaximal exercise and energy expenditure during maximal exercise using heart rate as input parameter were also evaluated. The accuracy of a semi-continuous heart rate estimation algorithm designed to reduce power consumption for long-term monitoring was also evaluated in various conditions. The main findings show that optical heart-rate sensors may be highly accurate during rhythmic sports activities, such as jogging, running, and cycling, including ramp-up running during maximal exercise testing. During non-rhythmic activities, such as intermittent hand movements, the sensors’ accuracy depends on where they are worn. During sleep and motionless conditions, the optical heart-rate sensors’ estimates for beat detection and inter-beat interval showed less than one percent inaccuracy against the values obtained using standard measurement techniques. The sensors were also sufficiently accurate at measuring the interbeat intervals to be used for calculating the heart rate variability parameters. The estimation accuracy of the fitness parameters derived from measured heart rate can be described as follows. An assessment of the maximal oxygen uptake estimation during a sub-maximal outdoor exercise had a precision close to a sport laboratory measurement. The energy expenditure estimation during a maximal exercise was more accurate during higher intensity of exercise above aerobic threshold but the accuracy decreased at lower intensity of exercise below the aerobic threshold, in comparison with the standardized reference measurement. The semi-continuous algorithm was nearly as accurate as continuous heart-rate detection, and there was a significant reduction in the power consumption of the optical chain components up to eighty percent. The results obtained from these studies show that, under certain conditions, optical sensors may be similarly accurate in measuring heart rate as the ‘gold standard’ methods and they can be relied on to monitor heart rate for various purposes during sport, everyday activities, or sleep

    Advanced sensors technology survey

    Get PDF
    This project assesses the state-of-the-art in advanced or 'smart' sensors technology for NASA Life Sciences research applications with an emphasis on those sensors with potential applications on the space station freedom (SSF). The objectives are: (1) to conduct literature reviews on relevant advanced sensor technology; (2) to interview various scientists and engineers in industry, academia, and government who are knowledgeable on this topic; (3) to provide viewpoints and opinions regarding the potential applications of this technology on the SSF; and (4) to provide summary charts of relevant technologies and centers where these technologies are being developed

    Fall detectors for people with dementia