10 research outputs found

    Lithium-Ion Batteries

    Get PDF
    Lithium-ion batteries (LIBs), as a key part of the 2019 Nobel Prize in Chemistry, have become increasingly important in recent years, owing to their potential impact on building a more sustainable future. Compared with other batteries developed, LIBs offer high energy density, high discharge power, and a long service life. These characteristics have facilitated a remarkable advance of LIBs in many frontiers, including electric vehicles, portable and flexible electronics, and stationary applications. Since the field of LIBs is advancing rapidly and attracting an increasing number of researchers, it is necessary to often provide the community with the latest updates. Therefore, this book was designed to focus on updating the electrochemical community with the latest advances and prospects on various aspects of LIBs. The materials presented in this book cover advances in several fronts of the technology, ranging from detailed fundamental studies of the electrochemical cell to investigations to better improve parameters related to battery packs

    Prussian Blue and Prussian White as electrode materials for Na-ion batteries: AxM{Fe(CN)6] (A=Na, K; M=Fe, Ti; 0<x<2)

    Get PDF
    199 p.Con el advenimiento de fuentes renovables intermitentes, los dispositivos de almacenamiento energético están siendo cada vez más demandados. Las baterías de ion litio son actualmente la tecnología preferida para alimentar dispositivos electrónicos portátiles y son ya una realidad en el mercado de vehículos eléctricos. Sin embargo, el bajo coste y la alta abundancia del sodio frente al litio, hace de las baterías de ion sodio una tecnología prometedora para aplicaciones estacionarias a gran escala, contrarrestando su menor capacidad gravimétrica, debido a su potencial ligeramente inferior. A pesar de las similitudes entre la química del litio y del sodio, se han encontrado diferencias importantes en el funcionamiento electroquímico de sus materiales activos. Las baterías de iones de sodio, requieren de materiales con cavidades suficientemente grandes para alojar al catión sodio, de mayor tamaño. Basándonos en la compresión de las baterías de litio, se han sintetizado y caracterizado mediante diversas técnicas espectroscópicas y de difracción, materiales ya conocidos y otros nuevos basados en el compuesto de Prussian Blue. Se han realizado investigaciones del comportamiento electroquímico de estas fases, que han demostrado que estos materiales pueden actuar como ánodos tanto para baterías de sodio y litio y también como cátodos en semiceldas de ion sodio. Y se han estudiado los mecanismos de inserción con la ayuda de varias técnicas de caracterización como rayos X, IR, SEM, TEM, XAS y Mössbauer. Además, se ha explorado su compatibilidad con electrolitos adecuados, así como la operatividad en celdas de iones de sodio completas de los cátodos previamente estudiados en semiceldas de ion sodio.El contenido del capítulo 2 sección 2.2.4.1.1 está sujeto a confidencialida

    Expanding the Scope of Impedance Spectroscopy for the Analysis of Adherent Cells: Electrode Material, Electrode Design, and Data Analysis

    Get PDF
    This thesis focused on the advancement of impedance-based cellular assays using the electric cell-substrate impedance sensing (ECIS) approach. Three linchpins of ECIS were addressed: electrode material, electrode design, and data analysis. Typically, ECIS measurements are performed by application of ac currents with low amplitude between coplanar gold-film electrodes with adherent cell monolayers growing on top. Different chapters of this work discussed the replacement of the electrode material gold by a conducting polymer, the use of a single bipolar electrode instead of two separate electrodes, and the data analysis by means of the derivatives of impedance spectra. The first part of this work dealt with the fabrication and characterization of screen printed polymer electrode arrays. The arrays, called PDT, were based on the conducting polymer PEDOT:PSS as electrode material, silver leads to reduce the lead resistance, and a silicone passivation layer to delineate the electrode dimensions. The electrodes showed high adhesion stability in aqueous environment at 37 °C, electrical stability in the analytically relevant voltage range between 10 mV and 300 mV, and long-term stability when stored in ambient air in the dark. In comparison with gold electrodes, PEDOT:PSS exhibited a greatly enhanced interface capacitance due to its hydrogel properties. This improved the sensitivity of the impedance magnitude |Z| and the real component of the impedance R at lower frequencies for cell analysis, which is relevant for the analysis of the barrier function and the cell-substrate interaction of adherent cell monolayers. Cell proliferation and adhesion assays are commonly conducted by monitoring the capacitance at 32 kHz or 40 kHz. In this frequency range, the sensitivity of the polymer electrodes surpassed the gold electrodes. A disadvantage of PEDOT:PSS was its high resistivity and thus the high lead resistance, reducing the sensitivities for the parameters |Z| and R at higher frequencies. Alterations in the cell-substrate contact as well as the adhesion and spreading kinetics compared to commercial gold electrodes were discussed with respect to the lower substrate stiffness of PEDOT:PSS compared to gold. Several common analytical assays investigating the micromotion, proliferation, cytotoxicity, and electroporation performance of the PEDOT:PSS electrodes were successfully conducted on both electrode materials, yielding overall similar results. Nevertheless, several differences were established. Due to the high interface capacitance, the PEDOT:PSS electrodes showed an extremely low noise level during micromotion experiments compared to the gold electrodes. This resulted in accordingly high signal-to-noise ratio and sensitivity. The proliferation assay provided more data scattering on PEDOT:PSS electrodes, which could be either attributed to the smaller electrode size or an inhomogeneous distribution of the substrate stiffness across the electrode surface. Due to a reduced generation of cytotoxic species at the electrode surface, the electroporation at lower frequencies (1.5 kHz) was found to be less invasive on PDT electrodes. Different cell lines with individual cell parameters were shown to retain their specific characteristics concerning barrier function, cell-substrate contact, and membrane capacitance on PEDOT:PSS. A remaining challenge is the electrode drift that occurred over the course of several days during the measurement. The drift was less pronounced in the impedance magnitude and appeared more prominently in the capacitance. In the second part of this work, a novel bipolar electrode for impedimetric analysis and manipulation of living cells was developed. The bipolar electrode consisted of a high-resistance conduction path showing a potential gradient along its length. The potential at the respective position on the electrode surface depended on its distance from the contact pads. Thus, upon application of elevated electric fields of 5 V for 60 s, the bipolar electrodes caused a gradient of increasing electric field strength along the conduction path. This property of the bipolar electrodes was explained by an increasing lead resistance with growing distance from the contact pads. The system is suggested to be suitable for the optimization of wounding and electroporation experiments as the position on the electrode indicates the optimal voltage amplitude required for the respective application. In a second approach, bipolar electrodes were fabricated comprising a passivation layer with a small working and a large counter electrode like in the ECIS layout. For this layout, a mathematical model based on the ECIS model was developed. Using this model, it was shown that the low frequency part of the impedance magnitude spectrum was determined by the inherent resistance of the bipolar electrode. Compared to ECIS electrodes, the bipolar electrodes showed a sensitivity shift from the real part to the imaginary part of the complex impedance. The third part of this work aimed to improve the accuracy of data analysis for impedance spectroscopy by calculating the derivatives of the spectra. Therefore, a set of methods was developed to analyze the applicability of derivative impedance spectroscopy (DIS) for the analysis of impedance-based cellular assays. Artificial raw data with known electrode and cell parameters were created by overlaying simulated impedance spectra with computer-generated noise. The derivative orders zero to three of these spectra were fitted using different settings of the fitting conditions and weighting methods. For a quantitative evaluation, the parameter Qrel was introduced, which is a direct measure for the quality of a fit. For certain fitting conditions the first derivative displayed some improvement compared to the zero-order spectrum. However, the overall tendency was a strong decline of the fit quality with increasing derivative order. This was found to be due to insufficient reduction of the noise, which is amplified after each differentiation. In a second approach, DIS was used to discriminate between spectral changes caused by alterations of either one of the cell parameters, α or Rb. Fixed frequencies were found, where simulations showed more distinct differences in the first or second derivative than in the zero-order spectrum. In particular, the first and second derivative exhibited opposing tendencies for the two cell parameters at 400 Hz and 1 kHz, respectively. Moreover, the migration of the zero-points of the second derivative when varying the cell parameters might become useful in a similar fashion. The high-frequency zero-point (~ 10 kHz) was shown to migrate only upon alteration of Rb and was unaffected by α. The results presented in this chapter are only valid for the investigated system and are not applicable to other cell lines

    Engineering Dynamics and Life Sciences

    Get PDF
    From Preface: This is the fourteenth time when the conference “Dynamical Systems: Theory and Applications” gathers a numerous group of outstanding scientists and engineers, who deal with widely understood problems of theoretical and applied dynamics. Organization of the conference would not have been possible without a great effort of the staff of the Department of Automation, Biomechanics and Mechatronics. The patronage over the conference has been taken by the Committee of Mechanics of the Polish Academy of Sciences and Ministry of Science and Higher Education of Poland. It is a great pleasure that our invitation has been accepted by recording in the history of our conference number of people, including good colleagues and friends as well as a large group of researchers and scientists, who decided to participate in the conference for the first time. With proud and satisfaction we welcomed over 180 persons from 31 countries all over the world. They decided to share the results of their research and many years experiences in a discipline of dynamical systems by submitting many very interesting papers. This year, the DSTA Conference Proceedings were split into three volumes entitled “Dynamical Systems” with respective subtitles: Vibration, Control and Stability of Dynamical Systems; Mathematical and Numerical Aspects of Dynamical System Analysis and Engineering Dynamics and Life Sciences. Additionally, there will be also published two volumes of Springer Proceedings in Mathematics and Statistics entitled “Dynamical Systems in Theoretical Perspective” and “Dynamical Systems in Applications”

    HASTECS: Hybrid Aircraft: reSearch on Thermal and Electric Components and Systems

    Get PDF
    In 2019, transportation was the fastest growing sector, contributing to environmental degradation. Finding sustainable solutions that pollute less is a key element in solving this problem, particularly for the aviation sector, which accounts for around 2-3% of global CO2 emissions. With the advent of Covid-19, air traffic seems to have come to a fairly permanent halt, but this pandemic reinforces the need to move towards a "cleaner sky" and respect for the environment, which is the objective of the Clean Sky2 program (H2020 EU), the context in which the HASTECS project has been launched in September 2016
    corecore