14 research outputs found

    Leveraging Spatiotemporal Relationships of High-frequency Activation in Human Electrocorticographic Recordings for Speech Brain-Computer-Interface

    Get PDF
    Speech production is one of the most intricate yet natural human behaviors and is most keenly appreciated when it becomes difficult or impossible; as is the case for patients suffering from locked-in syndrome. Burgeoning understanding of the various cortical representations of language has brought into question the viability of a speech neuroprosthesis using implanted electrodes. The temporal resolution of intracranial electrophysiological recordings, frequently billed as a great asset of electrocorticography (ECoG), has actually been a hindrance as speech decoders have struggled to take advantage of this timing information. There have been few demonstrations of how well a speech neuroprosthesis will realistically generalize across contexts when constructed using causal feature extraction and language models that can be applied and adapted in real-time. The research detailed in this dissertation aims primarily to characterize the spatiotemporal relationships of high frequency activity across ECoG arrays during word production. Once identified, these relationships map to motor and semantic representations of speech through the use of algorithms and classifiers that rapidly quantify these relationships in single-trials. The primary hypothesis put forward by this dissertation is that the onset, duration and temporal profile of high frequency activity in ECoG recordings is a useful feature for speech decoding. These features have rarely been used in state-of-the-art speech decoders, which tend to produce output from instantaneous high frequency power across cortical sites, or rely upon precise behavioral time-locking to take advantage of high frequency activity at several time-points relative to behavioral onset times. This hypothesis was examined in three separate studies. First, software was created that rapidly characterizes spatiotemporal relationships of neural features. Second, semantic representations of speech were examined using these spatiotemporal features. Finally, utterances were discriminated in single-trials with low latency and high accuracy using spatiotemporal matched filters in a neural keyword-spotting paradigm. Outcomes from this dissertation inform implant placement for a human speech prosthesis and provide the scientific and methodological basis to motivate further research of an implant specifically for speech-based brain-computer-interfaces

    The real-time molecular characterisation of human brain tumours during surgery using Rapid Evaporative Ionization Mass Spectrometry [REIMS] and Raman spectroscopy: a platform for precision medicine in neurosurgery

    Get PDF
    Aim: To investigate new methods for the chemical detection of tumour tissue during neurosurgery. Rationale: Surgeons operating on brain tumours currently lack the ability to directly and immediately assess the presence of tumour tissue to help guide resection. Through developing a first in human application of new technology we hope to demonstrate the proof of concept that chemical detection of tumour tissue is possible. It will be further demonstrated that information can be obtained to potentially aid treatment decisions. This new technology could, therefore, become a platform for more effective surgery and introducing precision medicine to Neurosurgery. Methods: Molecular analysis was performed using Raman spectroscopy and Rapid Evaporative Ionization Mass Spectrometry (REIMS). These systems were first developed for use in brain surgery. A single centre prospective observational study of both modalities was designed involving a total of 75 patients undergoing craniotomy and resection of a range of brain tumours. A neuronavigation system was used to register spectral readings in 3D space. Precise intraoperative readings from different tumour zones were taken and compared to matched core biopsy samples verified by routine histopathology. Results: Multivariate statistics including PCA/LDA analysis was used to analyse the spectra obtained and compare these to the histological data. The systems identified normal versus tumour tissue, tumour grade, tumour type, tumour density and tissue status of key markers of gliomagenesis. Conclusions: The work in this thesis provides proof of concept that useful real time intraoperative spectroscopy is possible. It can integrate well with the current operating room setup to provide key information which could potentially enhance surgical safety and effectiveness in increasing extent of resection. The ability to group tissue samples with respect to genomic data opens up the possibility of using this information during surgery to speed up treatment, escalate/deescalate surgery in specific phenotypic groups to introduce precision medicine to Neurosurgery.Open Acces

    Developmental delays and subcellular stress as downstream effects of sonoporation

    Get PDF
    Posters: no. 2Control ID: 1672434OBJECTIVES: The biological impact of sonoporation has often been overlooked. Here we seek to obtain insight into the cytotoxic impact of sonoporation by gaining new perspectives on anti-proliferative characteristics that may emerge within sonoporated cells. We particularly focused on investigating the cell-cycle progression kinetics of sonoporated cells and identifying organelles that may be stressed in the recovery process. METHODS: In line with recommendations on exposure hardware design, an immersion-based ultrasound platform has been developed. It delivers 1 MHz ultrasound pulses (100 cycles; 1 kHz PRF; 60 s total duration) with 0.45 MPa peak negative pressure to a cell chamber that housed HL-60 leukemia cells and lipid-shelled microbubbles at a 10:1 cell-tobubble ratio (for 1e6/ml cell density). Calcein was used to facilitate tracking of sonoporated cells with enhanced uptake of exogenous molecules. The developmental trend of sonoporated cells was quantitatively analyzed using BrdU/DNA flow cytometry that monitors the cell population’s DNA synthesis kinetics. This allowed us to measure the temporal progression of DNA synthesis of sonoporated cells. To investigate whether sonoporation would upset subcellular homeostasis, post-exposure cell samples were also assayed for various proteins using Western blot analysis. Analysis focus was placed on the endoplasmic reticulum (ER): an important organelle with multi-faceted role in cellular functioning. The post-exposure observation time spanned between 0-24 h. RESULTS: Despite maintaining viability, sonoporated cells were found to exhibit delays in cell-cycle progression. Specifically, their DNA synthesis time was lengthened substantially (for HL-60 cells: 8.7 h for control vs 13.4 h for the sonoporated group). This indicates that sonoporated cells were under stress: a phenomenon that is supported by our Western blot assays showing upregulation of ER-resident enzymes (PDI, Ero1), ER stress sensors (PERK, IRE1), and ER-triggered pro-apoptotic signals (CHOP, JNK). CONCLUSIONS: Sonoporation, whilst being able to facilitate internalization of exogenous molecules, may inadvertently elicit a cellular stress response. These findings seem to echo recent calls for reconsideration of efficiency issues in sonoporation-mediated drug delivery. Further efforts would be necessary to improve the efficiency of sonoporation-based biomedical applications where cell death is not desirable.postprin

    A study on the change in plasma membrane potential during sonoporation

    Get PDF
    Posters: no. 4Control ID: 1680329OBJECTIVES: There has been validated that the correlation of sonoporation with calcium transients is generated by ultrasound-mediated microbubbles activity. Besides calcium, other ionic flows are likely involved in sonoporation. Our hypothesis is the cell electrophysiological properties are related to the intracellular delivery by ultrasound and microbubbles. In this study, a real-time live cell imaging platform is used to determine whether plasma membrane potential change is related to the sonoporation process at the cellular level. METHODS: Hela cells were cultured in DMEM supplemented with 10% FBS in Opticell Chamber at 37 °C and 5% CO2, and reached 80% confluency before experiments. The Calcein Blue-AM, DiBAC4(3) loaded cells in the Opticell chamber filled with PI solution and Sonovue microbubbles were immerged in a water tank on a inverted fluorescence microscope. Pulsed ultrasound (1MHz freq., 20 cycles, 20Hz PRF, 0.2-0.5MPa PNP) was irradiated at the angle of 45° to the region of interest for 1s.The real-time fluorescence imaging for different probes was acquired by a cooled CCD camera every 20s for 10min. The time-lapse fluorescence images were quantitatively analyzed to evaluate the correlation of cell viability, intracellular delivery with plasma membrane potential change. RESULTS: Our preliminary data showed that the PI fluorescence, which indicated intracellular delivery, was immediately accumulated in cells adjacent to microbubbles after exposure, suggesting that their membranes were damaged by ultrasound-activated microbubbles. However, the fluorescence reached its highest level within 4 to 6 minutes and was unchanged thereafter, indicating the membrane was gradually repaired within this period. Furthermore, using DIBAC4(3), which detected the change in the cell membrane potential, we found that the loss of membrane potential might be associated with intracellular delivery, because the PI fluorescence accumulation was usually accompanied with the change in DIBAC4 (3) fluorescence. CONCLUSIONS: Our study suggests that there may be a linkage between the cell membrane potential change and intracellular delivery mediated by ultrasound and microbubbles. We also suggest that other ionic flows or ion channels may be involved in the cell membrane potential change in sonoporation. Further efforts to explore the cellular mechanism of this phenomenon will improve our understanding of sonoporation.postprin

    Imaging Sensors and Applications

    Get PDF
    In past decades, various sensor technologies have been used in all areas of our lives, thus improving our quality of life. In particular, imaging sensors have been widely applied in the development of various imaging approaches such as optical imaging, ultrasound imaging, X-ray imaging, and nuclear imaging, and contributed to achieve high sensitivity, miniaturization, and real-time imaging. These advanced image sensing technologies play an important role not only in the medical field but also in the industrial field. This Special Issue covers broad topics on imaging sensors and applications. The scope range of imaging sensors can be extended to novel imaging sensors and diverse imaging systems, including hardware and software advancements. Additionally, biomedical and nondestructive sensing applications are welcome

    Separator fluid volume requirements in multi-infusion settings

    Get PDF
    INTRODUCTION. Intravenous (IV) therapy is a widely used method for the administration of medication in hospitals worldwide. ICU and surgical patients in particular often require multiple IV catheters due to incompatibility of certain drugs and the high complexity of medical therapy. This increases discomfort by painful invasive procedures, the risk of infections and costs of medication and disposable considerably. When different drugs are administered through the same lumen, it is common ICU practice to flush with a neutral fluid between the administration of two incompatible drugs in order to optimally use infusion lumens. An important constraint for delivering multiple incompatible drugs is the volume of separator fluid that is sufficient to safely separate them. OBJECTIVES. In this pilot study we investigated whether the choice of separator fluid, solvent, or administration rate affects the separator volume required in a typical ICU infusion setting. METHODS. A standard ICU IV line (2m, 2ml, 1mm internal diameter) was filled with methylene blue (40 mg/l) solution and flushed using an infusion pump with separator fluid. Independent variables were solvent for methylene blue (NaCl 0.9% vs. glucose 5%), separator fluid (NaCl 0.9% vs. glucose 5%), and administration rate (50, 100, or 200 ml/h). Samples were collected using a fraction collector until <2% of the original drug concentration remained and were analyzed using spectrophotometry. RESULTS. We did not find a significant effect of administration rate on separator fluid volume. However, NaCl/G5% (solvent/separator fluid) required significantly less separator fluid than NaCl/NaCl (3.6 ± 0.1 ml vs. 3.9 ± 0.1 ml, p <0.05). Also, G5%/G5% required significantly less separator fluid than NaCl/NaCl (3.6 ± 0.1 ml vs. 3.9 ± 0.1 ml, p <0.05). The significant decrease in required flushing volume might be due to differences in the viscosity of the solutions. However, mean differences were small and were most likely caused by human interactions with the fluid collection setup. The average required flushing volume is 3.7 ml. CONCLUSIONS. The choice of separator fluid, solvent or administration rate had no impact on the required flushing volume in the experiment. Future research should take IV line length, diameter, volume and also drug solution volumes into account in order to provide a full account of variables affecting the required separator fluid volume
    corecore