229 research outputs found

    A Comparative Evaluation of Heart Rate Estimation Methods using Face Videos

    Full text link
    This paper presents a comparative evaluation of methods for remote heart rate estimation using face videos, i.e., given a video sequence of the face as input, methods to process it to obtain a robust estimation of the subjects heart rate at each moment. Four alternatives from the literature are tested, three based in hand crafted approaches and one based on deep learning. The methods are compared using RGB videos from the COHFACE database. Experiments show that the learning-based method achieves much better accuracy than the hand crafted ones. The low error rate achieved by the learning based model makes possible its application in real scenarios, e.g. in medical or sports environments.Comment: Accepted in "IEEE International Workshop on Medical Computing (MediComp) 2020

    A Reproducible Study on Remote Heart Rate Measurement

    Get PDF
    This paper studies the problem of reproducible research in remote photoplethysmography (rPPG). Most of the work published in this domain is assessed on privately-owned databases, making it difficult to evaluate proposed algorithms in a standard and principled manner. As a consequence, we present a new, publicly available database containing a relatively large number of subjects recorded under two different lighting conditions. Also, three state-of-the-art rPPG algorithms from the literature were selected, implemented and released as open source free software. After a thorough, unbiased experimental evaluation in various settings, it is shown that none of the selected algorithms is precise enough to be used in a real-world scenario

    Exploring remote photoplethysmography signals for deepfake detection in facial videos

    Get PDF
    Abstract. With the advent of deep learning-based facial forgeries, also called "deepfakes", the feld of accurately detecting forged videos has become a quickly growing area of research. For this endeavor, remote photoplethysmography, the process of extracting biological signals such as the blood volume pulse and heart rate from facial videos, offers an interesting avenue for detecting fake videos that appear utterly authentic to the human eye. This thesis presents an end-to-end system for deepfake video classifcation using remote photoplethysmography. The minuscule facial pixel colour changes are used to extract the rPPG signal, from which various features are extracted and used to train an XGBoost classifer. The classifer is then tested using various colour-to-blood volume pulse methods (OMIT, POS, LGI and CHROM) and three feature extraction window lengths of two, four and eight seconds. The classifer was found effective at detecting deepfake videos with an accuracy of 85 %, with minimal performance difference found between the window lengths. The GREEN channel signal was found to be important for this classifcationEtäfotoplethysmografian hyödyntäminen syväväärennösten tunnistamiseen. Tiivistelmä. Syväväärennösten eli syväoppimiseen perustuvien kasvoväärennöksien yleistyessä väärennösten tarkasta tunnistamisesta koneellisesti on tullut nopeasti kasvava tutkimusalue. Etäfotoplethysmografa (rPPG) eli biologisten signaalien kuten veritilavuuspulssin tai sykkeen mittaaminen videokuvasta tarjoaa kiinnostavan keinon tunnistaa väärennöksiä, jotka vaikuttavat täysin aidoilta ihmissilmälle. Tässä diplomityössä esitellään etäfotoplethysmografaan perustuva syväväärennösten tunnistusmetodi. Kasvojen minimaalisia värimuutoksia hyväksikäyttämällä mitataan fotoplethysmografasignaali, josta lasketuilla ominaisuuksilla koulutetaan XGBoost-luokittelija. Luokittelijaa testataan usealla eri värisignaalista veritilavuussignaaliksi muuntavalla metodilla sekä kolmella eri ominaisuuksien ikkunapituudella. Luokittelija pystyy tunnistamaan väärennetyn videon aidosta 85 % tarkkuudella. Eri ikkunapituuksien välillä oli minimaalisia eroja, ja vihreän värin signaalin havaittiin olevan luokittelun suorituskyvyn kannalta merkittävä

    Analisis Photoplethysmography Jarak Jauh dalam berbagai Kondisi Pencahayaan

    Get PDF
    Photoplethysmography (PPG) konvensional untuk mengukur kecepatan jantung memiliki keterbatasan tersendiri, salah satunya yaitu diperlukannya kontak langsung dengan bagian tubuh pasien. rPPG (remote-Photoplethysmography) dapat digunakan untuk melakukan pemantauan jantung dari seorang pasien berbasis citra. Sama halnya dengan sistem lain yang berbasis kamera, algoritma rPPG sangat bergantung pada kondisi pencahayaan. Oleh karena itu diperlukan suatu studi analisis yang mengindahkan aspek tentang pengaruh kondisi dan arah cahaya terhadap subjek yang diamati terhadap hasil estimasi laju denyut jantung dengan algoritma rPPG. Pada penelitian ini diimplementasikan algoritma rPPG dengan Short-Time Fourier Transform (STFT) untuk memperkirakan laju detak jantung dalam berbagai kondisi cahaya. Hasil yang diperoleh merupakan analisa spektral dari perubahan frame video pada area dahi terhadap perubahan waktu dari model input warna Green-Channel dan HSV (Hue, Saturation, Value). Perbandingan dengan pengukuran ground truth pada pencahayaan 260 lux, 19 lux, dan 11 lux, estimasi laju detak jantung yang didapatkan dari input Green Channel menghasilkan persentase error rata-rata 0,038, 0,118, dan 0,229, dimana hasil persentase rata-rata error ini lebih rendah dari masukan HSV, yaitu 0,095, 0,212, dan 0,24

    Remote Assessment of the Cardiovascular Function Using Camera-Based Photoplethysmography

    Get PDF
    Camera-based photoplethysmography (cbPPG) is a novel measurement technique that allows the continuous monitoring of vital signs by using common video cameras. In the last decade, the technology has attracted a lot of attention as it is easy to set up, operates remotely, and offers new diagnostic opportunities. Despite the growing interest, cbPPG is not completely established yet and is still primarily the object of research. There are a variety of reasons for this lack of development including that reliable and autonomous hardware setups are missing, that robust processing algorithms are needed, that application fields are still limited, and that it is not completely understood which physiological factors impact the captured signal. In this thesis, these issues will be addressed. A new and innovative measuring system for cbPPG was developed. In the course of three large studies conducted in clinical and non-clinical environments, the system’s great flexibility, autonomy, user-friendliness, and integrability could be successfully proven. Furthermore, it was investigated what value optical polarization filtration adds to cbPPG. The results show that a perpendicular filter setting can significantly enhance the signal quality. In addition, the performed analyses were used to draw conclusions about the origin of cbPPG signals: Blood volume changes are most likely the defining element for the signal's modulation. Besides the hardware-related topics, the software topic was addressed. A new method for the selection of regions of interest (ROIs) in cbPPG videos was developed. Choosing valid ROIs is one of the most important steps in the processing chain of cbPPG software. The new method has the advantage of being fully automated, more independent, and universally applicable. Moreover, it suppresses ballistocardiographic artifacts by utilizing a level-set-based approach. The suitability of the ROI selection method was demonstrated on a large and challenging data set. In the last part of the work, a potentially new application field for cbPPG was explored. It was investigated how cbPPG can be used to assess autonomic reactions of the nervous system at the cutaneous vasculature. The results show that changes in the vasomotor tone, i.e. vasodilation and vasoconstriction, reflect in the pulsation strength of cbPPG signals. These characteristics also shed more light on the origin problem. Similar to the polarization analyses, they support the classic blood volume theory. In conclusion, this thesis tackles relevant issues regarding the application of cbPPG. The proposed solutions pave the way for cbPPG to become an established and widely accepted technology

    Effectiveness of Remote PPG Construction Methods: A Preliminary Analysis

    Get PDF
    The contactless recording of a photoplethysmography (PPG) signal with a Red-Green-Blue (RGB) camera is known as remote photoplethysmography (rPPG). Studies have reported on the positive impact of using this technique, particularly in heart rate estimation, which has led to increased research on this topic among scientists. Therefore, converting from RGB signals to constructing an rPPG signal is an important step. Eight rPPG methods (plant-orthogonal-to-skin (POS), local group invariance (LGI), the chrominance-based method (CHROM), orthogonal matrix image transformation (OMIT), GREEN, independent component analysis (ICA), principal component analysis (PCA), and blood volume pulse (PBV) methods) were assessed using dynamic time warping, power spectrum analysis, and Pearson’s correlation coefficient, with different activities (at rest, during exercising in the gym, during talking, and while head rotating) and four regions of interest (ROI): the forehead, the left cheek, the right cheek, and a combination of all three ROIs. The best performing rPPG methods in all categories were the POS, LGI, and OMI methods; each performed well in all activities. Recommendations for future work are provided

    Optimal color channel combination across skin tones for remote heart rate measurement in camera-based photoplethysmography

    Get PDF
    Objective: The heart rate is an essential vital sign that can be measured remotely with camera-based photoplethysmography (cbPPG). Systems for cbPPG typically use cameras that deliver red, green, and blue (RGB) channels. The combination of these channels has been proven to increase signal-to-noise ratio (SNR) and heart rate measurement accuracy (ACC). However, many combinations remain untested, the comparison of proposed combinations on large datasets is insufficiently investigated, and the interplay with skin tone is rarely addressed. Methods: Eight regions of interest and eight color spaces with a total of 25 color channels were compared in terms of ACC and SNR based on the Binghamton-Pittsburgh-RPI Multimodal Spontaneous Emotion Database (BP4D+). Additionally, two systematic grid searches were performed to evaluate ACC in the space of linear combinations of the RGB channels. Results: Glabella and forehead regions of interest provided highest ACC (up to 74.1 %) and SNR (> -3 dB) with the hue channel H from HSV color space and the chrominance channel Q from NTSC color space. The grid searches revealed a global optimum of linear RGB combinations (ACC: 79.2 %). This optimum occurred for all skin tones, although ACC dropped for darker skin tones. Conclusion: Through systematic grid searches we were able to identify the skin tone independent optimal linear RGB color combination for measuring heart rate with cbPPG. Our results proved on a large dataset that the identified optimum outperformed conventionally used color channels. Significance: The presented findings provide useful evidence for future considerations of algorithmic approaches for cbPPG

    Remote Bio-Sensing: Open Source Benchmark Framework for Fair Evaluation of rPPG

    Full text link
    Remote Photoplethysmography (rPPG) is a technology that utilizes the light absorption properties of hemoglobin, captured via camera, to analyze and measure blood volume pulse (BVP). By analyzing the measured BVP, various physiological signals such as heart rate, stress levels, and blood pressure can be derived, enabling applications such as the early prediction of cardiovascular diseases. rPPG is a rapidly evolving field as it allows the measurement of vital signals using camera-equipped devices without the need for additional devices such as blood pressure monitors or pulse oximeters, and without the assistance of medical experts. Despite extensive efforts and advances in this field, serious challenges remain, including issues related to skin color, camera characteristics, ambient lighting, and other sources of noise, which degrade performance accuracy. We argue that fair and evaluable benchmarking is urgently required to overcome these challenges and make any meaningful progress from both academic and commercial perspectives. In most existing work, models are trained, tested, and validated only on limited datasets. Worse still, some studies lack available code or reproducibility, making it difficult to fairly evaluate and compare performance. Therefore, the purpose of this study is to provide a benchmarking framework to evaluate various rPPG techniques across a wide range of datasets for fair evaluation and comparison, including both conventional non-deep neural network (non-DNN) and deep neural network (DNN) methods. GitHub URL: https://github.com/remotebiosensing/rppg.Comment: 19 pages, 10 figure
    • …
    corecore