44,499 research outputs found

    Applications of MEMS Gyroscope for Human Gait Analysis

    Get PDF
    After decades of development, quantitative instruments for human gait analysis have become an important tool for revealing underlying pathologies manifested by gait abnormalities. However, the gold standard instruments (e.g., optical motion capture systems) are commonly expensive and complex while needing expert operation and maintenance and thereby be limited to a small number of specialized gait laboratories. Therefore, in current clinical settings, gait analysis still mainly relies on visual observation and assessment. Due to recent developments in microelectromechanical systems (MEMS) technology, the cost and size of gyroscopes are decreasing, while the accuracy is being improved, which provides an effective way for qualifying gait features. This chapter aims to give a close examination of human gait patterns (normal and abnormal) using gyroscope-based wearable technology. Both healthy subjects and hemiparesis patients participated in the experiment, and experimental results show that foot-mounted gyroscopes could assess gait abnormalities in both temporal and spatial domains. Gait analysis systems constructed of wearable gyroscopes can be more easily used in both clinical and home environments than their gold standard counterparts, which have few requirements for operation, maintenance, and working environment, thereby suggesting a promising future for gait analysis

    Human Gait Analysis in Neurodegenerative Diseases: a Review

    Get PDF
    This paper reviews the recent literature on technologies and methodologies for quantitative human gait analysis in the context of neurodegnerative diseases. The use of technological instruments can be of great support in both clinical diagnosis and severity assessment of these pathologies. In this paper, sensors, features and processing methodologies have been reviewed in order to provide a highly consistent work that explores the issues related to gait analysis. First, the phases of the human gait cycle are briefly explained, along with some non-normal gait patterns (gait abnormalities) typical of some neurodegenerative diseases. The work continues with a survey on the publicly available datasets principally used for comparing results. Then the paper reports the most common processing techniques for both feature selection and extraction and for classification and clustering. Finally, a conclusive discussion on current open problems and future directions is outlined

    Measuring Glide Reflection Symmetry in Human Movements

    Get PDF
    abstract: Many studies on human walking pattern assume that adult gait is characterized by bilateral symmetrical behavior. It is well understood that maintaining symmetry in walking patterns increases energetic eciency. We present a framework to provide a quantitative assessment of human walking patterns, especially assessments related to symmetric and asymmetric gait patterns purely based on glide reflection. A Gliding symmetry score is calculated from the data obtained from Motion Capture(MoCap) system. Six primary joints (Shoulder, Elbow, Palm, Hip, Knee, Foot) are considered for this study. Two dierent abnormalities were chosen and studied carefully. All the two gaits were mimicked in controlled environment. The framework proposed clearly showed that it could distinguish the abnormal gaits from the ordinary walking patterns. This framework can be widely used by the doctors and physical therapists for kinematics analysis, bio-mechanics, motion capture research, sports medicine and physical therapy, including human gait analysis and injury rehabilitation.Dissertation/ThesisMasters Thesis Electrical Engineering 201

    Knee Joint Angle Measuring Portable Embedded System based on Inertial Measurement Units for Gait Analysis

    Get PDF
    Inside clinical research, gait analysis is a fundamental part of the functional evaluation of the human body's movement. Its evaluation has been carried out through different methods and tools, which allow early diagnosis of diseases, and monitoring and assessing the effectiveness of therapeutic plans applied to patients for rehabilitation. The observational method is one of the most used in specialized centers in Colombia; however, to avoid any possible errors associated with the subjectivity observation, technological tools that provide quantitative data can support this method. This paper deals with the methodological process for developing a computational tool and hardware device for the analysis of gait, specifically on articular kinematics of the knee.  This work develops a prototype based on the fusion of inertial measurement units (IMU) data as an alternative for the attenuation of errors associated with each of these technologies. A videogrammetry technique measured the same human gait patterns to validate the proposed system, in terms of accuracy and repeatability of the recorded data. Results showed that the developed prototype successfully captured the knee-joint angles of the flexion-extension motions with high consistency and accuracy in with the measurements obtained from the videogrammetry technique. Statistical analysis (ICC and RMSE) exhibited a high correlation between the two systems for the measures of the joint angles. These results suggest the possibility of using an IMU-based prototype in realistic scenarios for accurately tracking a patient’s knee-joint kinematics during a human gait

    Stratification of the phase clouds and statistical effects of the non-Markovity in chaotic time series of human gait for healthy people and Parkinson patients

    Full text link
    In this work we develop a new method of diagnosing the nervous system diseases and a new approach in studying human gait dynamics with the help of the theory of discrete non-Markov random processes. The stratification of the phase clouds and the statistical non-Markov effects in the time series of the dynamics of human gait are considered. We carried out the comparative analysis of the data of four age groups of healthy people: children (from 3 to 10 year olds), teenagers (from 11 to 14 year oulds), young people (from 21 up to 29 year oulds), elderly persons (from 71 to 77 year olds) and Parkinson patients. The full data set are analyzed with the help of the phase portraits of the four dynamic variables, the power spectra of the initial time correlation function and the memory functions of junior orders, the three first points in the spectra of the statistical non-Markov parameter. The received results allow to define the predisposition of the probationers to deflections in the central nervous system caused by Parkinson's disease. We have found out distinct differencies between the five submitted groups. On this basis we offer a new method of diagnostics and forecasting Parkinson's disease.Comment: 15 pages, 5 figs, 3 Table

    Development and Application of 3D Kinematic Methodologies for Biomechanical Modelling in Adaptive Sports and Rehabilitation

    Get PDF
    Biomechanical analysis is widely used to assess human movement sciences, specifically using three-dimensional motion capture modelling. There are unprecedented opportunities to increase quantitative knowledge of rehabilitation and recreation for disadvantaged population groups. Specifically, 3D models and movement profiles for human gait analysis were generated with emphasis on post-stroke patients, with direct model translation to analyze equivalent measurements while horseback riding in use of the alternative form of rehabilitation, equine assisted activities and therapies (EAAT) or hippotherapy (HPOT). Significant improvements in gait symmetry and velocity were found within an inpatient rehabilitation setting for patients following a stroke, and the developed movement profiles for patients have the potential to address patient recovery timelines. For population groups, such as those following a cerebral incident, alternative forms of rehabilitation like EAAT and HPOT are largely unexplored. Within these studies, relevant muscular activations were found between healthy human gait and horseback riding, supporting the belief that horseback riding can stimulate similar movements within the rider. Even more, there was a strong correlation between the horse’s pelvic rotations, and the responsive joint moments and rotations of the rider. These findings could have greater implications in choosing horses, depending on the desired physical outcome, for EAAT and HPOT purposes. Similar approaches were also used to address another biomechanically disadvantage population, adaptive sport athletes. Utilizing similar methodologies, a novel 3D wheelchair tennis athlete model was created to analyze match-simulation assessments. Significant findings were present in the energy expenditure between two drill assessments. Overall, the quantitative results, coupled with the qualitative assessment chapter, provide a robust assessment of the effects of 3D movement analysis on rehabilitation and adaptive activities

    Is the timed-up and go test feasible in mobile devices? A systematic review

    Get PDF
    The number of older adults is increasing worldwide, and it is expected that by 2050 over 2 billion individuals will be more than 60 years old. Older adults are exposed to numerous pathological problems such as Parkinson’s disease, amyotrophic lateral sclerosis, post-stroke, and orthopedic disturbances. Several physiotherapy methods that involve measurement of movements, such as the Timed-Up and Go test, can be done to support efficient and effective evaluation of pathological symptoms and promotion of health and well-being. In this systematic review, the authors aim to determine how the inertial sensors embedded in mobile devices are employed for the measurement of the different parameters involved in the Timed-Up and Go test. The main contribution of this paper consists of the identification of the different studies that utilize the sensors available in mobile devices for the measurement of the results of the Timed-Up and Go test. The results show that mobile devices embedded motion sensors can be used for these types of studies and the most commonly used sensors are the magnetometer, accelerometer, and gyroscope available in off-the-shelf smartphones. The features analyzed in this paper are categorized as quantitative, quantitative + statistic, dynamic balance, gait properties, state transitions, and raw statistics. These features utilize the accelerometer and gyroscope sensors and facilitate recognition of daily activities, accidents such as falling, some diseases, as well as the measurement of the subject's performance during the test execution.info:eu-repo/semantics/publishedVersio

    Wearable Platform for Automatic Recognition of Parkinson Disease by Muscular Implication Monitoring

    Get PDF
    The need for diagnostic tools for the characterization of progressive movement disorders - as the Parkinson Disease (PD) - aiming to early detect and monitor the pathology is getting more and more impelling. The parallel request of wearable and wireless solutions, for the real-time monitoring in a non-controlled environment, has led to the implementation of a Quantitative Gait Analysis platform for the extraction of muscular implications features in ordinary motor action, such as gait. The here proposed platform is used for the quantification of PD symptoms. Addressing the wearable trend, the proposed architecture is able to define the real-time modulation of the muscular indexes by using 8 EMG wireless nodes positioned on lower limbs. The implemented system “translates” the acquisition in a 1-bit signal, exploiting a dynamic thresholding algorithm. The resulting 1-bit signals are used both to define muscular indexes both to drastically reduce the amount of data to be analyzed, preserving at the same time the muscular information. The overall architecture has been fully implemented on Altera Cyclone V FPGA. The system has been tested on 4 subjects: 2 affected by PD and 2 healthy subjects (control group). The experimental results highlight the validity of the proposed solution in Disease recognition and the outcomes match the clinical literature results

    Sagittal Subtalar and Talocrural Joint Assessment With Weight-Bearing Fluoroscopy During Barefoot Ambulation

    Get PDF
    Background: Identifying talar position during ambulation has proved difficult as the talus lacks palpable landmarks for skin marker placement and more invasive methodologies such as bone pins are not practical for most clinical subjects. A fluoroscopic motion system was used to track the talus and calcaneus, allowing kinematic analysis of the talocrural and subtalar joints. Methods: Thirteen male subjects (mean age 22.9 ± 3.0 years) previously screened for normal gait were tested. A fluoroscopy unit was used to collect images at 120 fps during stance. Sagittal motion of the talocrural and subtalar joints were analyzed. Results: The intersubject mean and standard deviation values for all 58 trials of 13 subjects are reported. Maximum talocrural joint plantarflexion of 11.2 degrees (4.3 degrees of standard deviation) occurred at 11% stance and maximum dorsiflexion of −6.9 degrees (5.6 degrees of standard deviation) occurred at 85%. Maximum subtalar joint plantarflexion of 4.8 degrees (1.0 degrees of standard deviation) occurred at 96% stance and maximum dorsiflexion of −3.6 degrees (2.3 degrees of standard deviation) occurred at 30%. Talocrural and subtalar range of motion values during stance were 18.1 and 8.4 degrees, respectively. Conclusion: Existing fluoroscopic technology was capable of defining sagittal plane talocrural and subtalar motion during gait. These kinematic results compare favorably with more invasive techniques. This type of assessment could support more routine analysis of in vivo bony motion during gait. Clinical Relevance: Fluoroscopic technology offers improved sagittal plane motion evaluation during weight-bearing with potential application in patients with end-stage ankle arthritis, postoperative ankle replacements and fusions, and orthotics and braces
    • 

    corecore