138,113 research outputs found

    A portable load cell for in-situ ore impact breakage testing

    Get PDF
    This paper discusses the design and characterisation of a short, and hence portable impact load cell for in-situ quantification of ore breakage properties under impact loading conditions. Much literature has been published in the past two decades about impact load cells for ore breakage testing. It has been conclusively shown that such machines yield significant quantitative energy-fragmentation information about industrial ores. However, documented load cells are all laboratory systems that are not adapted for in-situ testing due to their dimensions and operating requirements. The authors report on a new portable impact load cell designed specifically for in-situ testing. The load cell is 1.5 m in height and weighs 30 kg. Its physical and operating characteristics are detailed in the paper. This includes physical dimensions, calibration and signal deconvolution. Emphasis is placed on the deconvolution issue, which is significant for such a short load cell. Finally, it is conclusively shown that the short load cell is quantitatively as accurate as its larger laboratory analogues

    Assessing Ageing Condition of Mineral Oil-Paper Insulation by Polarization/Depolarization Current

    No full text
    Accurately assessing the ageing status of oil-paper insulation in transformer is essential and important. Polarization and Depolarization Current (PDC) technique is effective in assessing the condition of oil-paper insulation system. Though the PDC behaviour of mineral oil-paper insulation has been widely investigated, there is no report about how to make the quantitative analysis of mineral oil-paper insulation ageing condition by PDC. The PDC characteristics of mineral oil-paper insulation samples were investigated over the ageing period at 110°C. A new method for assessing the ageing condition of mineral oil-paper insulation by calculating the depolarization charge quantity was proposed. Results show that the depolarization charge quantity of mineral oil-paper insulation sample is very sensitive to its ageing condition. The stable depolarization charge quantity could be used to predict the ageing condition of mineral oil-paper insulation

    Validating Cable "Diagnostic Tests"

    Get PDF
    Presented at Jicable '07.Diagnostic Techniques are increasingly employed by utilities to manage their infrastructure assets. These are sophisticated techniques being applied to complicated and diverse real world networks. Consequently there are many concerns that these techniques a) are not accurate and b) damage the system by, at the very least, robbing other areas of vitally short resources. Thus there is a compelling need to develop and deploy simple and robust analytical techniques that can address these problems. These evaluation approaches would then identify the effective programmes such that support could be strengthened to these areas, whilst minimizing the resources deployed on approaches that are ineffective

    Evaluation of Lightning Impulse Test by Frequency Response Analysis

    Get PDF
    In this work are presented the basis for improving the interpretation of transformer lightning impulse test and the development of a graphical user interface system, which allows comparisons of time domain data and frequency response. The frequency response is obtained from deconvolution of voltage and neutral current records. A quantitative comparison of frequency response is performed using the techniques applied to displacement detection through Frequency Response Analysis, such as correlation and spectral deviation. The system is implemented using 8 bit digitizers to acquire the voltage and neutral current records. The quantization error and reliability of the frequency response obtained is handled through the use of the coherence function and tolerance bands. The system is thoroughly tested applying a lightning impulse test to a dry type distribution transformer, simulating an interdisc fault with a spark gap. Failure detection is confirmed

    Voltage dip immunity aspects of power-electronic equipment : recommendations from CIGRE/CIRED/UIE JWG C4.110

    Get PDF
    This paper presents some of the results from an international working group on voltage-dip immunity. The working group has made a number of recommendations to reduce the adverse impact of voltage dips. Specific recommendations to researchers and manufacturers of powerelectronic equipment are considering all voltage dip characteristics early in the design of equipment; characterize performance of equipment by means of voltage-dip immunity curves; and made equipment with different immunity available

    Inter-laboratory comparison of a WDS-EDS quantitative X-ray microanalysis of a metallic glass

    Get PDF
    We conducted an inter-laboratory study of a metallic glass whose main component is nickel. Two determinations of the mass fractions of the different elements present within the sample were asked to the participants: one at an acceleration voltage of 15 or 20 kV and another one at 5 kV. We compare the mass fractions obtained from wavelength dispersive (WDS) and energy dispersive spectrometries (EDS) and also try to find an influence of the kind of EDS detector and its entrance window, the background subtraction method, the use or not of standards as well as the quantification method. Both means of WDS and EDS mass fractions are close to the reference values. The dispersion of the results was larger at 5 kV than at 15-20 kV owing to the use of the L lines rather than K lines and to the lowest collected intensities. There is an exception with the case of boron because at the lowest voltage, the excitation condition is more favourable for the production of the K line. It appears that the dispersion of the results is larger with EDS than with WDS but it was not possible to find a correlation between the large dispersion and one of the considered experimental parameters and quantification factors. Thus, one can think that electron microprobes are inherently better for the determination of mass fractions or that the implementation of quantitative analysis must be optimized for some cases, especially in SEMs.Comment: Members of the GN-MEBA, SEMPA users group and Belgian laboratories coordinated by Universite Catholique de Louvain are thanked for their participation to this inter-laboratory stud

    Requirements to Testing of Power System Services Provided by DER Units

    Get PDF
    The present report forms the Project Deliverable ‘D 2.2’ of the DERlab NoE project, supported by the EC under Contract No. SES6-CT-518299 NoE DERlab. The present document discuss the power system services that may be provided from DER units and the related methods to test the services actually provided, both at component level and at system level

    Pulse position type fluxgate sensors

    Get PDF
    • 

    corecore