1,941 research outputs found

    Visual enhancements in pick-and-place tasks: Human operators controlling a simulated cylindrical manipulator

    Get PDF
    A teleoperation simulator was constructed with vector display system, joysticks, and a simulated cylindrical manipulator, in order to quantitatively evaluate various display conditions. The first of two experiments conducted investigated the effects of perspective parameter variations on human operators' pick-and-place performance, using a monoscopic perspective display. The second experiment involved visual enhancements of the monoscopic perspective display, by adding a grid and reference lines, by comparison with visual enhancements of a stereoscopic display; results indicate that stereoscopy generally permits superior pick-and-place performance, but that monoscopy nevertheless allows equivalent performance when defined with appropriate perspective parameter values and adequate visual enhancements

    A helmet mounted display to adapt the telerobotic environment to human vision

    Get PDF
    A Helmet Mounted Display system has been developed. It provides the capability to display stereo images with the viewpoint tied to subjects' head orientation. The type of display might be useful in a telerobotic environment provided the correct operating parameters are known. The effects of update frequency were tested using a 3D tracking task. The effects of blur were tested using both tracking and pick-and-place tasks. For both, researchers found that operator performance can be degraded if the correct parameters are not used. Researchers are also using the display to explore the use of head movements as part of gaze as subjects search their visual field for target objects

    Operator vision aids for space teleoperation assembly and servicing

    Get PDF
    This paper investigates concepts for visual operator aids required for effective telerobotic control. Operator visual aids, as defined here, mean any operational enhancement that improves man-machine control through the visual system. These concepts were derived as part of a study of vision issues for space teleoperation. Extensive literature on teleoperation, robotics, and human factors was surveyed to definitively specify appropriate requirements. This paper presents these visual aids in three general categories of camera/lighting functions, display enhancements, and operator cues. In the area of camera/lighting functions concepts are discussed for: (1) automatic end effector or task tracking; (2) novel camera designs; (3) computer-generated virtual camera views; (4) computer assisted camera/lighting placement; and (5) voice control. In the technology area of display aids, concepts are presented for: (1) zone displays, such as imminent collision or indexing limits; (2) predictive displays for temporal and spatial location; (3) stimulus-response reconciliation displays; (4) graphical display of depth cues such as 2-D symbolic depth, virtual views, and perspective depth; and (5) view enhancements through image processing and symbolic representations. Finally, operator visual cues (e.g., targets) that help identify size, distance, shape, orientation and location are discussed

    Displays for telemanipulation

    Get PDF
    Visual displays drive the human operator's highest bandwidth sensory input channel. Thus, no telemanipulation system is adequate which does not make extensive use of visual displays. Although an important use of visual displays is the presentation of a televised image of the work scene, visual displays are examined for presentation of nonvisual information (forces and torques) for simulation and planning, and for management and control of the large numbers of subsystems which make up a modern telemanipulation system

    Stereoscopic bimanual interaction for 3D visualization

    Get PDF
    Virtual Environments (VE) are being widely used in various research fields for several decades such as 3D visualization, education, training and games. VEs have the potential to enhance the visualization and act as a general medium for human-computer interaction (HCI). However, limited research has evaluated virtual reality (VR) display technologies, monocular and binocular depth cues, for human depth perception of volumetric (non-polygonal) datasets. In addition, a lack of standardization of three-dimensional (3D) user interfaces (UI) makes it challenging to interact with many VE systems. To address these issues, this dissertation focuses on evaluation of effects of stereoscopic and head-coupled displays on depth judgment of volumetric dataset. It also focuses on evaluation of a two-handed view manipulation techniques which support simultaneous 7 degree-of-freedom (DOF) navigation (x,y,z + yaw,pitch,roll + scale) in a multi-scale virtual environment (MSVE). Furthermore, this dissertation evaluates auto-adjustment of stereo view parameters techniques for stereoscopic fusion problems in a MSVE. Next, this dissertation presents a bimanual, hybrid user interface which combines traditional tracking devices with computer-vision based "natural" 3D inputs for multi-dimensional visualization in a semi-immersive desktop VR system. In conclusion, this dissertation provides a guideline for research design for evaluating UI and interaction techniques

    Machine vision based teleoperation aid

    Get PDF
    When teleoperating a robot using video from a remote camera, it is difficult for the operator to gauge depth and orientation from a single view. In addition, there are situations where a camera mounted for viewing by the teleoperator during a teleoperation task may not be able to see the tool tip, or the viewing angle may not be intuitive (requiring extensive training to reduce the risk of incorrect or dangerous moves by the teleoperator). A machine vision based teleoperator aid is presented which uses the operator's camera view to compute an object's pose (position and orientation), and then overlays onto the operator's screen information on the object's current and desired positions. The operator can choose to display orientation and translation information as graphics and/or text. This aid provides easily assimilated depth and relative orientation information to the teleoperator. The camera may be mounted at any known orientation relative to the tool tip. A preliminary experiment with human operators was conducted and showed that task accuracies were significantly greater with than without this aid

    Three dimensional tracking with misalignment between display and control axes

    Get PDF
    Human operators confronted with misaligned display and control frames of reference performed three dimensional, pursuit tracking in virtual environment and virtual space simulations. Analysis of the components of the tracking errors in the perspective displays presenting virtual space showed that components of the error due to visual motor misalignment may be linearly separated from those associated with the mismatch between display and control coordinate systems. Tracking performance improved with several hours practice despite previous reports that such improvement did not take place

    Aerospace Medicine and Biology: A continuing bibliography with indexes, supplement 192

    Get PDF
    This bibliography lists 247 reports, articles, and other documents introduced into the NASA scientific and technical information system in March 1979

    Calibration Methods for Head-Tracked 3D Displays

    Get PDF
    Head-tracked 3D displays can provide a compelling 3D effect, but even small inaccuracies in the calibration of the participant’s viewpoint to the display can disrupt the 3D illusion. We propose a novel interactive procedure for a participant to easily and accurately calibrate a head-tracked display by visually aligning patterns across a multi-screen display. Head-tracker measurements are then calibrated to these known viewpoints. We conducted a user study to evaluate the effectiveness of different visual patterns and different display shapes. We found that the easiest to align shape was the spherical display and the best calibration pattern was the combination of circles and lines. We performed a quantitative camera-based calibration of a cubic display and found visual calibration outperformed manual tuning and generated viewpoint calibrations accurate to within a degree. Our work removes the usual, burdensome step of manual calibration when using head-tracked displays and paves the way for wider adoption of this inexpensive and effective 3D display technology

    Software Framework for Customized Augmented Reality Headsets in Medicine

    Get PDF
    The growing availability of self-contained and affordable augmented reality headsets such as the Microsoft HoloLens is encouraging the adoption of these devices also in the healthcare sector. However, technological and human-factor limitations still hinder their routine use in clinical practice. Among them, the major drawbacks are due to their general-purpose nature and to the lack of a standardized framework suited for medical applications and devoid of platform-dependent tracking techniques and/or complex calibration procedures. To overcome such limitations, in this paper we present a software framework that is designed to support the development of augmented reality applications for custom-made head-mounted displays designed to aid high-precision manual tasks. The software platform is highly configurable, computationally efficient, and it allows the deployment of augmented reality applications capable to support in situ visualization of medical imaging data. The framework can provide both optical and video see-through-based augmentations and it features a robust optical tracking algorithm. An experimental study was designed to assess the efficacy of the platform in guiding a simulated task of surgical incision. In the experiments, the user was asked to perform a digital incision task, with and without the aid of the augmented reality headset. The task accuracy was evaluated by measuring the similarity between the traced curve and the planned one. The average error in the augmented reality tests was < 1 mm. The results confirm that the proposed framework coupled with the new-concept headset may boost the integration of augmented reality headsets into routine clinical practice
    • …
    corecore