1,899 research outputs found

    ECG Signal Compression Using Discrete Wavelet Transform

    Get PDF

    Improving Maternal and Fetal Cardiac Monitoring Using Artificial Intelligence

    Get PDF
    Early diagnosis of possible risks in the physiological status of fetus and mother during pregnancy and delivery is critical and can reduce mortality and morbidity. For example, early detection of life-threatening congenital heart disease may increase survival rate and reduce morbidity while allowing parents to make informed decisions. To study cardiac function, a variety of signals are required to be collected. In practice, several heart monitoring methods, such as electrocardiogram (ECG) and photoplethysmography (PPG), are commonly performed. Although there are several methods for monitoring fetal and maternal health, research is currently underway to enhance the mobility, accuracy, automation, and noise resistance of these methods to be used extensively, even at home. Artificial Intelligence (AI) can help to design a precise and convenient monitoring system. To achieve the goals, the following objectives are defined in this research: The first step for a signal acquisition system is to obtain high-quality signals. As the first objective, a signal processing scheme is explored to improve the signal-to-noise ratio (SNR) of signals and extract the desired signal from a noisy one with negative SNR (i.e., power of noise is greater than signal). It is worth mentioning that ECG and PPG signals are sensitive to noise from a variety of sources, increasing the risk of misunderstanding and interfering with the diagnostic process. The noises typically arise from power line interference, white noise, electrode contact noise, muscle contraction, baseline wandering, instrument noise, motion artifacts, electrosurgical noise. Even a slight variation in the obtained ECG waveform can impair the understanding of the patient's heart condition and affect the treatment procedure. Recent solutions, such as adaptive and blind source separation (BSS) algorithms, still have drawbacks, such as the need for noise or desired signal model, tuning and calibration, and inefficiency when dealing with excessively noisy signals. Therefore, the final goal of this step is to develop a robust algorithm that can estimate noise, even when SNR is negative, using the BSS method and remove it based on an adaptive filter. The second objective is defined for monitoring maternal and fetal ECG. Previous methods that were non-invasive used maternal abdominal ECG (MECG) for extracting fetal ECG (FECG). These methods need to be calibrated to generalize well. In other words, for each new subject, a calibration with a trustable device is required, which makes it difficult and time-consuming. The calibration is also susceptible to errors. We explore deep learning (DL) models for domain mapping, such as Cycle-Consistent Adversarial Networks, to map MECG to fetal ECG (FECG) and vice versa. The advantages of the proposed DL method over state-of-the-art approaches, such as adaptive filters or blind source separation, are that the proposed method is generalized well on unseen subjects. Moreover, it does not need calibration and is not sensitive to the heart rate variability of mother and fetal; it can also handle low signal-to-noise ratio (SNR) conditions. Thirdly, AI-based system that can measure continuous systolic blood pressure (SBP) and diastolic blood pressure (DBP) with minimum electrode requirements is explored. The most common method of measuring blood pressure is using cuff-based equipment, which cannot monitor blood pressure continuously, requires calibration, and is difficult to use. Other solutions use a synchronized ECG and PPG combination, which is still inconvenient and challenging to synchronize. The proposed method overcomes those issues and only uses PPG signal, comparing to other solutions. Using only PPG for blood pressure is more convenient since it is only one electrode on the finger where its acquisition is more resilient against error due to movement. The fourth objective is to detect anomalies on FECG data. The requirement of thousands of manually annotated samples is a concern for state-of-the-art detection systems, especially for fetal ECG (FECG), where there are few publicly available FECG datasets annotated for each FECG beat. Therefore, we will utilize active learning and transfer-learning concept to train a FECG anomaly detection system with the least training samples and high accuracy. In this part, a model is trained for detecting ECG anomalies in adults. Later this model is trained to detect anomalies on FECG. We only select more influential samples from the training set for training, which leads to training with the least effort. Because of physician shortages and rural geography, pregnant women's ability to get prenatal care might be improved through remote monitoring, especially when access to prenatal care is limited. Increased compliance with prenatal treatment and linked care amongst various providers are two possible benefits of remote monitoring. If recorded signals are transmitted correctly, maternal and fetal remote monitoring can be effective. Therefore, the last objective is to design a compression algorithm that can compress signals (like ECG) with a higher ratio than state-of-the-art and perform decompression fast without distortion. The proposed compression is fast thanks to the time domain B-Spline approach, and compressed data can be used for visualization and monitoring without decompression owing to the B-spline properties. Moreover, the stochastic optimization is designed to retain the signal quality and does not distort signal for diagnosis purposes while having a high compression ratio. In summary, components for creating an end-to-end system for day-to-day maternal and fetal cardiac monitoring can be envisioned as a mix of all tasks listed above. PPG and ECG recorded from the mother can be denoised using deconvolution strategy. Then, compression can be employed for transmitting signal. The trained CycleGAN model can be used for extracting FECG from MECG. Then, trained model using active transfer learning can detect anomaly on both MECG and FECG. Simultaneously, maternal BP is retrieved from the PPG signal. This information can be used for monitoring the cardiac status of mother and fetus, and also can be used for filling reports such as partogram

    Wireless body area sensor networks signal processing and communication framework: Survey on sensing, communication technologies, delivery and feedback

    Get PDF
    Problem statement: The Wireless Body Area Sensor Networks (WBASNs) is a wireless network used for communication among sensor nodes operating on or inside the human body in order to monitor vital body parameters and movements.This study surveys the state-of-the-art on Wireless Body Area Networks, discussing the major components of research in this area including physiological sensing and preprocessing, WBASNs communication techniques and data fusion for gathering data from sensors.In addition, data analysis and feedback will be presented including feature extraction, detection and classification of human related phenomena.Approach: Comparative studies of the technologies and techniques used in such systems will be provided in this study, using qualitative comparisons and use case analysis to give insight on potential uses for different techniques.Results and Conclusion: Wireless Sensor Networks (WSNs) technologies are considered as one of the key of the research areas in computer science and healthcare application industries.Sensor supply chain and communication technologies used within the system and power consumption therein, depend largely on the use case and the characteristics of the application.Authors conclude that Life-saving applications and thorough studies and tests should be conducted before WBANs can be widely applied to humans, particularly to address the challenges related to robust techniques for detection and classification to increase the accuracy and hence the confidence of applying such techniques without physician intervention

    Review of sensors for remote patient monitoring

    Get PDF
    Remote patient monitoring (RPM) of physiological measurements can provide an efficient method and high quality care to patients. The physiological signals measurement is the initial and the most important factor in RPM. This paper discusses the characteristics of the most popular sensors, which are used to obtain vital clinical signals in prevalent RPM systems. The sensors discussed in this paper are used to measure ECG, heart sound, pulse rate, oxygen saturation, blood pressure and respiration rate, which are treated as the most important vital data in patient monitoring and medical examination

    Modeling of electrocardiogram signals using predefined signature and envelope vector sets

    Get PDF
    A novel method is proposed to model ECG signals by means of "predefined signature and envelope vector sets (PSEVS)." On a frame basis, an ECG signal is reconstructed by multiplying three model parameters, namely, predefined signature vector (PSV)(R)," "predefined envelope vector (PEV)(K)," and frame-scaling coefficient (FSC). All the PSVs and PEVs are labeled and stored in their respective sets to describe the signal in the reconstruction process. In this case, an ECG signal frame is modeled by means of the members of these sets labeled with indices R and K and the frame-scaling coefficient, in the least mean square sense. The proposed method is assessed through the use of percentage root-mean-square difference (PRD) and visual inspection measures. Assessment results reveal that the proposed method provides significant data compression ratio (CR) with low-level PRD values while preserving diagnostic information. This fact significantly reduces the bandwidth of communication in telediagnosis operations. Copyright (c) 2007 Hakan Gurkan et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.Publisher's Versio

    Biomedical Applications of the Discrete Wavelet Transform

    Get PDF

    Design of a secure architecture for the exchange of biomedical information in m-Health scenarios

    Get PDF
    El paradigma de m-Salud (salud móvil) aboga por la integración masiva de las más avanzadas tecnologías de comunicación, red móvil y sensores en aplicaciones y sistemas de salud, para fomentar el despliegue de un nuevo modelo de atención clínica centrada en el usuario/paciente. Este modelo tiene por objetivos el empoderamiento de los usuarios en la gestión de su propia salud (p.ej. aumentando sus conocimientos, promocionando estilos de vida saludable y previniendo enfermedades), la prestación de una mejor tele-asistencia sanitaria en el hogar para ancianos y pacientes crónicos y una notable disminución del gasto de los Sistemas de Salud gracias a la reducción del número y la duración de las hospitalizaciones. No obstante, estas ventajas, atribuidas a las aplicaciones de m-Salud, suelen venir acompañadas del requisito de un alto grado de disponibilidad de la información biomédica de sus usuarios para garantizar una alta calidad de servicio, p.ej. fusionar varias señales de un usuario para obtener un diagnóstico más preciso. La consecuencia negativa de cumplir esta demanda es el aumento directo de las superficies potencialmente vulnerables a ataques, lo que sitúa a la seguridad (y a la privacidad) del modelo de m-Salud como factor crítico para su éxito. Como requisito no funcional de las aplicaciones de m-Salud, la seguridad ha recibido menos atención que otros requisitos técnicos que eran más urgentes en etapas de desarrollo previas, tales como la robustez, la eficiencia, la interoperabilidad o la usabilidad. Otro factor importante que ha contribuido a retrasar la implementación de políticas de seguridad sólidas es que garantizar un determinado nivel de seguridad implica unos costes que pueden ser muy relevantes en varias dimensiones, en especial en la económica (p.ej. sobrecostes por la inclusión de hardware extra para la autenticación de usuarios), en el rendimiento (p.ej. reducción de la eficiencia y de la interoperabilidad debido a la integración de elementos de seguridad) y en la usabilidad (p.ej. configuración más complicada de dispositivos y aplicaciones de salud debido a las nuevas opciones de seguridad). Por tanto, las soluciones de seguridad que persigan satisfacer a todos los actores del contexto de m-Salud (usuarios, pacientes, personal médico, personal técnico, legisladores, fabricantes de dispositivos y equipos, etc.) deben ser robustas y al mismo tiempo minimizar sus costes asociados. Esta Tesis detalla una propuesta de seguridad, compuesta por cuatro grandes bloques interconectados, para dotar de seguridad a las arquitecturas de m-Salud con unos costes reducidos. El primer bloque define un esquema global que proporciona unos niveles de seguridad e interoperabilidad acordes con las características de las distintas aplicaciones de m-Salud. Este esquema está compuesto por tres capas diferenciadas, diseñadas a la medidas de los dominios de m-Salud y de sus restricciones, incluyendo medidas de seguridad adecuadas para la defensa contra las amenazas asociadas a sus aplicaciones de m-Salud. El segundo bloque establece la extensión de seguridad de aquellos protocolos estándar que permiten la adquisición, el intercambio y/o la administración de información biomédica -- por tanto, usados por muchas aplicaciones de m-Salud -- pero no reúnen los niveles de seguridad detallados en el esquema previo. Estas extensiones se concretan para los estándares biomédicos ISO/IEEE 11073 PHD y SCP-ECG. El tercer bloque propone nuevas formas de fortalecer la seguridad de los tests biomédicos, que constituyen el elemento esencial de muchas aplicaciones de m-Salud de carácter clínico, mediante codificaciones novedosas. Finalmente el cuarto bloque, que se sitúa en paralelo a los anteriores, selecciona herramientas genéricas de seguridad (elementos de autenticación y criptográficos) cuya integración en los otros bloques resulta idónea, y desarrolla nuevas herramientas de seguridad, basadas en señal -- embedding y keytagging --, para reforzar la protección de los test biomédicos.The paradigm of m-Health (mobile health) advocates for the massive integration of advanced mobile communications, network and sensor technologies in healthcare applications and systems to foster the deployment of a new, user/patient-centered healthcare model enabling the empowerment of users in the management of their health (e.g. by increasing their health literacy, promoting healthy lifestyles and the prevention of diseases), a better home-based healthcare delivery for elderly and chronic patients and important savings for healthcare systems due to the reduction of hospitalizations in number and duration. It is a fact that many m-Health applications demand high availability of biomedical information from their users (for further accurate analysis, e.g. by fusion of various signals) to guarantee high quality of service, which on the other hand entails increasing the potential surfaces for attacks. Therefore, it is not surprising that security (and privacy) is commonly included among the most important barriers for the success of m-Health. As a non-functional requirement for m-Health applications, security has received less attention than other technical issues that were more pressing at earlier development stages, such as reliability, eficiency, interoperability or usability. Another fact that has contributed to delaying the enforcement of robust security policies is that guaranteeing a certain security level implies costs that can be very relevant and that span along diferent dimensions. These include budgeting (e.g. the demand of extra hardware for user authentication), performance (e.g. lower eficiency and interoperability due to the addition of security elements) and usability (e.g. cumbersome configuration of devices and applications due to security options). Therefore, security solutions that aim to satisfy all the stakeholders in the m-Health context (users/patients, medical staff, technical staff, systems and devices manufacturers, regulators, etc.) shall be robust and, at the same time, minimize their associated costs. This Thesis details a proposal, composed of four interrelated blocks, to integrate appropriate levels of security in m-Health architectures in a cost-efcient manner. The first block designes a global scheme that provides different security and interoperability levels accordingto how critical are the m-Health applications to be implemented. This consists ofthree layers tailored to the m-Health domains and their constraints, whose security countermeasures defend against the threats of their associated m-Health applications. Next, the second block addresses the security extension of those standard protocols that enable the acquisition, exchange and/or management of biomedical information | thus, used by many m-Health applications | but do not meet the security levels described in the former scheme. These extensions are materialized for the biomedical standards ISO/IEEE 11073 PHD and SCP-ECG. Then, the third block proposes new ways of enhancing the security of biomedical standards, which are the centerpiece of many clinical m-Health applications, by means of novel codings. Finally the fourth block, with is parallel to the others, selects generic security methods (for user authentication and cryptographic protection) whose integration in the other blocks results optimal, and also develops novel signal-based methods (embedding and keytagging) for strengthening the security of biomedical tests. The layer-based extensions of the standards ISO/IEEE 11073 PHD and SCP-ECG can be considered as robust, cost-eficient and respectful with their original features and contents. The former adds no attributes to its data information model, four new frames to the service model |and extends four with new sub-frames|, and only one new sub-state to the communication model. Furthermore, a lightweight architecture consisting of a personal health device mounting a 9 MHz processor and an aggregator mounting a 1 GHz processor is enough to transmit a 3-lead electrocardiogram in real-time implementing the top security layer. The extra requirements associated to this extension are an initial configuration of the health device and the aggregator, tokens for identification/authentication of users if these devices are to be shared and the implementation of certain IHE profiles in the aggregator to enable the integration of measurements in healthcare systems. As regards to the extension of SCP-ECG, it only adds a new section with selected security elements and syntax in order to protect the rest of file contents and provide proper role-based access control. The overhead introduced in the protected SCP-ECG is typically 2{13 % of the regular file size, and the extra delays to protect a newly generated SCP-ECG file and to access it for interpretation are respectively a 2{10 % and a 5 % of the regular delays. As regards to the signal-based security techniques developed, the embedding method is the basis for the proposal of a generic coding for tests composed of biomedical signals, periodic measurements and contextual information. This has been adjusted and evaluated with electrocardiogram and electroencephalogram-based tests, proving the objective clinical quality of the coded tests, the capacity of the coding-access system to operate in real-time (overall delays of 2 s for electrocardiograms and 3.3 s for electroencephalograms) and its high usability. Despite of the embedding of security and metadata to enable m-Health services, the compression ratios obtained by this coding range from ' 3 in real-time transmission to ' 5 in offline operation. Complementarily, keytagging permits associating information to images (and other signals) by means of keys in a secure and non-distorting fashion, which has been availed to implement security measures such as image authentication, integrity control and location of tampered areas, private captioning with role-based access control, traceability and copyright protection. The tests conducted indicate a remarkable robustness-capacity tradeoff that permits implementing all this measures simultaneously, and the compatibility of keytagging with JPEG2000 compression, maintaining this tradeoff while setting the overall keytagging delay in only ' 120 ms for any image size | evidencing the scalability of this technique. As a general conclusion, it has been demonstrated and illustrated with examples that there are various, complementary and structured manners to contribute in the implementation of suitable security levels for m-Health architectures with a moderate cost in budget, performance, interoperability and usability. The m-Health landscape is evolving permanently along all their dimensions, and this Thesis aims to do so with its security. Furthermore, the lessons learned herein may offer further guidance for the elaboration of more comprehensive and updated security schemes, for the extension of other biomedical standards featuring low emphasis on security or privacy, and for the improvement of the state of the art regarding signal-based protection methods and applications

    Design and evaluation of echocardiograms codification and transmission for Teleradiology systems

    Get PDF
    Las enfermedades cardiovasculares son la mayor causa de muerte en el mundo. Aunque la mayoría de muertes por cardiopatías se puede evitar, si las medidas preventivas no son las adecuadas el paciente puede fallecer. Es por esto, que el seguimiento y diagnóstico de pacientes con cardiopatías es muy importante. Numerosos son las pruebas médicas para el diagnostico y seguimiento de enfermedades cardiovasculares, siendo los ecocardiogramas una de las técnicas más ampliamente utilizada. Un ecocardiograma consiste en la adquisición de imágenes del corazón mediante ultrasonidos. Presenta varias ventajas con respecto otras pruebas de imagen: no es invasiva, no produce radiación ionizante y es barata. Por otra parte, los sistemas de telemedicina han crecido rápidamente ya que ofrecen beneficios de acceso a los servicios médicos, una reducción del coste y una mejora de la calidad de los servicios. La telemedicina proporciona servicios médicos a distancia. Estos servicios son de especial ayuda en casos de emergencia médica y para áreas aisladas donde los hospitales y centros de salud están alejados. Los sistemas de tele-cardiología pueden ser clasificados de acuerdo al tipo de pruebas. En esta Tesis nos hemos centrado en los sistemas de tele-ecocardiografia, ya que los ecocardiogramas son ampliamente usados y presentan el mayor reto al ser la prueba médica con mayor flujo de datos. Los mayores retos en los sistemas de tele-ecocardiografia son la compresión y la transmisión garantizando que el mismo diagnóstico es posible tanto en el ecocardiograma original como en el reproducido tras la compresión y transmisión. Los ecocardiogramas deben ser comprimidos tanto para su almacenamiento como para su transmisión ya que estos presentan un enorme flujo de datos que desbordaría el espacio de almacenamiento y no se podría transmitir eficientemente por las redes actuales. Sin embargo, la compresión produce pérdidas que pueden llevar a un diagnostico erróneo de los ecocardiogramas comprimidos. En el caso de que las pruebas ecocardiograficas quieran ser guardadas, una compresión clínica puede ser aplicada previa al almacenamiento. Esta compresión clínica consiste en guardar las partes del ecocardiograma que son importantes para el diagnóstico, es decir, ciertas imágenes y pequeños vídeos del corazón en movimiento que contienen de 1 a 3 ciclos cardiacos. Esta compresión clínica no puede ser aplicada en el caso de transmisión en tiempo real, ya que es el cardiólogo especialista quien debe realizar la compresión clínica y éste se encuentra en recepción, visualizando el echocardiograma transmitido. En cuanto a la transmisión, las redes sin cables presentan un mayor reto que las redes cableadas. Las redes sin cables tienen un ancho de banda limitado, son propensas a errores y son variantes en tiempo lo que puede resultar problemático cuando el ecocardiograma quiere ser transmitido en tiempo real. Además, las redes sin cables han experimentado un gran desarrollo gracias a que permiten un mejor acceso y movilidad, por lo que pueden ofrecer un mayor servicio que las redes cableadas. Dos tipos de sistemas se pueden distinguir acorde a los retos que presenta cada uno de ellos: los sistemas de almacenamiento y reenvió y los sistemas de tiempo real. Los sistemas de almacenamiento y reenvió consisten en la adquisición, almacenamiento y el posterior envió del ecocardiograma sin requerimientos temporales. Una compresión clínica puede ser llevada a cabo previa al almacenamiento. Además de la compresión clínica, una compresión con pérdidas es recomendada para reducir el espacio de almacenamiento y el tiempo de envío, pero sin perder l ainformación diagnóstica de la prueba. En cuanto a la transmisión, al no haber requerimientos temporales, la transmisión no presenta ninguna dificultad. Cualquier protocolo de transmisión fiable puede ser usado para no perder calidad en la imagen debido a la transmisión. Por lo tanto, para estos sistemas sólo nos hemos centrado en la codificación de los ecocardiogramas. Los sistemas de tiempo real consisten en la transmisión del ecocardiograma al mismo tiempo que éste es adquirido. Dado que el envío de video clínico es una de las aplicaciones con mayor demanda de ancho de banda, la compresión para la transmisión es requerida, pero manteniendo la calidad diagnóstica de la imagen. La transmisión en canales sin cables puede ser afectada por errores que distorsionan la calidad del ecocardiograma reconstruido en recepción. Por lo tanto, métodos de control de errores son requeridos para minimizar los errores de transmisión y el retardo introducido. Sin embargo, aunque el ecocardiograma sea visualizado con errores debido a la transmisión, esto no implica que el diagnóstico no sea posible. Dados los retos previamente descritos, las siguientes soluciones para la evaluación clínica, compresión y transmisión han sido propuestas: - Para garantizar que el ecocardiograma es visualizado sin perder información diagnóstica 2 tests han sido diseñados. El primer test define recomendaciones para la compresión de los ecocardiogramas. Consiste en dos fases para un ahorro en el tiempo de realización, pero sin perder por ello exactitud en el proceso de evaluación. Gracias a este test el ecocardiograma puede ser comprimido al máximo sin perder calidad diagnóstica y utilizando así más eficientemente los recursos. El segundo test define recomendaciones para la visualización del ecocardiograma. Este test define rangos de tiempo en los que el ecocardiograma puede ser visualizado con inferior calidad a la establecida en el primer test. Gracias a este test se puede saber si el ecocardiograma es visualizado sin pérdida de calidad diagnóstica cuando se introducen errores en la visualización, sin la necesidad de realizar una evaluación para cada video transmitido o diferentes condiciones de canal. Además, esta metodología puede ser aplicada para la evaluación de otras técnicas de diagnóstico por imagen. - Para la compresión de ecocardiogramas dos métodos de compresión han sido diseñados, uno para el almacenamiento y otro para la transmisión. Diferentes propuestas son diseñadas, ya que los ecocardiogramas para los dos propósitos tienen características diferentes. Para ambos propósitos un método de compresión en la que las facilidades que incorporan los dispositivos de segmentar la imagen y en la que las características de visualización de los ecocardiogramas han sido tenidas en cuenta ha sido diseñado. Para la compresión del ecocardiograma con el propósito de almacenarlo un formato de almacenamiento fácilmente integrable con DICOM basado en regiones y en el que el tipo de datos y la importancia clínica de cada región es tenido en cuenta ha sido diseñado. DICOM es el formato para el almacenamiento y transmisión de imágenes más ampliamente utilizado actualmente. El formato de compresión propuesto supone un ahorra de hasta el 75 % del espacio de almacenamiento con respecto a la compresión con JPEG 2000, actualmente soportado por DICOM, sin perder calidad diagnostica de la imagen. Los ratios de compresión para el formato propuesto dependen de la distribución de la imagen, pero para una base de datos de 105 ecocardiogramas correspondientes a 4 ecógrafos los ratios obtenidos están comprendidos entre 19 y 41. Para la compresión del ecocardiograma con el propósito de la transmisión en tiempo real un método de compresión basado en regiones en el que el tipo de dato y el modo de visualización han sido tenidos en cuenta se ha diseñado. Dos modos de visualización son distinguidos para la compresión de la región con mayor importancia clínica (ultrasonido), los modos de barrido y los modos 2-D. La evaluación clínica diseñada para las recomendaciones de compresión fue llevada a cabo por 3 cardiologos, 9 ecocardiogramas correspondientes a diferentes pacientes y 3 diferentes ecógrafos. Los ratios de transmisión recomendados fueron de 200 kbps para los modos 2-D y de 40 kbps para los modos de barrido. Si se comparan estos resultados con previas soluciones en la literatura un ahorro mínimo de entre 5 % y el 78 % es obtenido dependiendo del modo. - Para la transmisión en tiempo real de ecocardiogramas un protocolo extremo a extremo basada en el método de compresión por regiones ha sido diseñado. Este protocolo llamado ETP de las siglas en inglés Echocardiogram Transmssion Protocol está diseñado para la compresión y transmisión de las regiones por separado, pudiendo así ofrecer diferentes ratios de compresión y protección de errores para las diferentes regiones de acuerdo a su importancia diagnostica. Por lo tanto, con ETP el ratio de transmisión mínimo recomendado para el método de compresión propuesto puede ser utilizado, usando así eficientemente el ancho de banda y siendo menos sensible a los errores introducidos por la red. ETP puede ser usado en cualquier red, sin embargo, en el caso de que la red introduzca errores se ha diseñado un método de corrección de errores llamado SECM, de las siglas en inglés State Error Control Method. SECM se adapta a las condiciones de canal usando más protección cuando las condiciones empeoran y usando así el ancho de banda eficientemente. Además, la evaluación clínica diseñada para las recomendaciones de visualización ha sido llevada a cabo con la base de datos de la evaluación previa. De esta forma se puede saber si el ecocardiograma es visualizado sin pérdida diagnostica aunque se produzcan errores de transmisión. En esta tesis, por lo tanto, se ha ofrecido una solución para la transmisión en tiempo real y el almacenamiento de ecocardiogramas preservando la información diagnóstica y usando eficientemente los recursos (disco de almacenamiento y ratio de transmisión). Especial soporte se da para la transmisión en redes sin cables, dando soluciones a las limitaciones que estas introducen. Además, las soluciones propuestas han sido probadas y comparadas con otras técnicas con una red de acceso móvil WiMAX, demostrando que el ancho de banda es eficientemente utilizado y que el ecocardiograma es correctamente visualizado de acuerdo con las recomendaciones de visualización dadas por la evaluación clínica
    corecore