2,921 research outputs found
A continuum robotic platform for endoscopic non-contact laser surgery: design, control, and preclinical evaluation
The application of laser technologies in surgical interventions has been accepted in the clinical
domain due to their atraumatic properties. In addition to manual application of fibre-guided
lasers with tissue contact, non-contact transoral laser microsurgery (TLM) of laryngeal tumours
has been prevailed in ENT surgery. However, TLM requires many years of surgical training
for tumour resection in order to preserve the function of adjacent organs and thus preserve the
patient’s quality of life. The positioning of the microscopic laser applicator outside the patient
can also impede a direct line-of-sight to the target area due to anatomical variability and limit
the working space. Further clinical challenges include positioning the laser focus on the tissue
surface, imaging, planning and performing laser ablation, and motion of the target area during
surgery. This dissertation aims to address the limitations of TLM through robotic approaches and
intraoperative assistance. Although a trend towards minimally invasive surgery is apparent, no
highly integrated platform for endoscopic delivery of focused laser radiation is available to date.
Likewise, there are no known devices that incorporate scene information from endoscopic imaging
into ablation planning and execution. For focusing of the laser beam close to the target tissue, this
work first presents miniaturised focusing optics that can be integrated into endoscopic systems.
Experimental trials characterise the optical properties and the ablation performance. A robotic
platform is realised for manipulation of the focusing optics. This is based on a variable-length
continuum manipulator. The latter enables movements of the endoscopic end effector in five
degrees of freedom with a mechatronic actuation unit. The kinematic modelling and control of the
robot are integrated into a modular framework that is evaluated experimentally. The manipulation
of focused laser radiation also requires precise adjustment of the focal position on the tissue. For
this purpose, visual, haptic and visual-haptic assistance functions are presented. These support
the operator during teleoperation to set an optimal working distance. Advantages of visual-haptic
assistance are demonstrated in a user study. The system performance and usability of the overall
robotic system are assessed in an additional user study. Analogous to a clinical scenario, the
subjects follow predefined target patterns with a laser spot. The mean positioning accuracy of the
spot is 0.5 mm. Finally, methods of image-guided robot control are introduced to automate laser
ablation. Experiments confirm a positive effect of proposed automation concepts on non-contact
laser surgery.Die Anwendung von Lasertechnologien in chirurgischen Interventionen hat sich aufgrund der atraumatischen Eigenschaften in der Klinik etabliert. Neben manueller Applikation von fasergefĂĽhrten
Lasern mit Gewebekontakt hat sich die kontaktfreie transorale Lasermikrochirurgie (TLM) von
Tumoren des Larynx in der HNO-Chirurgie durchgesetzt. Die TLM erfordert zur Tumorresektion
jedoch ein langjähriges chirurgisches Training, um die Funktion der angrenzenden Organe zu
sichern und damit die Lebensqualität der Patienten zu erhalten. Die Positionierung des mikroskopis chen Laserapplikators außerhalb des Patienten kann zudem die direkte Sicht auf das Zielgebiet
durch anatomische Variabilität erschweren und den Arbeitsraum einschränken. Weitere klinische
Herausforderungen betreffen die Positionierung des Laserfokus auf der Gewebeoberfläche, die
Bildgebung, die Planung und AusfĂĽhrung der Laserablation sowie intraoperative Bewegungen
des Zielgebietes. Die vorliegende Dissertation zielt darauf ab, die Limitierungen der TLM durch
robotische Ansätze und intraoperative Assistenz zu adressieren. Obwohl ein Trend zur minimal
invasiven Chirurgie besteht, sind bislang keine hochintegrierten Plattformen fĂĽr die endoskopische
Applikation fokussierter Laserstrahlung verfĂĽgbar. Ebenfalls sind keine Systeme bekannt, die
Szeneninformationen aus der endoskopischen Bildgebung in die Ablationsplanung und -ausfĂĽhrung
einbeziehen. Für eine situsnahe Fokussierung des Laserstrahls wird in dieser Arbeit zunächst
eine miniaturisierte Fokussieroptik zur Integration in endoskopische Systeme vorgestellt. Experimentelle Versuche charakterisieren die optischen Eigenschaften und das Ablationsverhalten. Zur
Manipulation der Fokussieroptik wird eine robotische Plattform realisiert. Diese basiert auf einem
längenveränderlichen Kontinuumsmanipulator. Letzterer ermöglicht in Kombination mit einer
mechatronischen Aktuierungseinheit Bewegungen des Endoskopkopfes in fĂĽnf Freiheitsgraden.
Die kinematische Modellierung und Regelung des Systems werden in ein modulares Framework
eingebunden und evaluiert. Die Manipulation fokussierter Laserstrahlung erfordert zudem eine
präzise Anpassung der Fokuslage auf das Gewebe. Dafür werden visuelle, haptische und visuell haptische Assistenzfunktionen eingeführt. Diese unterstützen den Anwender bei Teleoperation
zur Einstellung eines optimalen Arbeitsabstandes. In einer Anwenderstudie werden Vorteile der
visuell-haptischen Assistenz nachgewiesen. Die Systemperformanz und Gebrauchstauglichkeit
des robotischen Gesamtsystems werden in einer weiteren Anwenderstudie untersucht. Analog zu
einem klinischen Einsatz verfolgen die Probanden mit einem Laserspot vorgegebene Sollpfade. Die
mittlere Positioniergenauigkeit des Spots beträgt dabei 0,5 mm. Zur Automatisierung der Ablation
werden abschließend Methoden der bildgestützten Regelung vorgestellt. Experimente bestätigen
einen positiven Effekt der Automationskonzepte fĂĽr die kontaktfreie Laserchirurgie
Robot Autonomy for Surgery
Autonomous surgery involves having surgical tasks performed by a robot
operating under its own will, with partial or no human involvement. There are
several important advantages of automation in surgery, which include increasing
precision of care due to sub-millimeter robot control, real-time utilization of
biosignals for interventional care, improvements to surgical efficiency and
execution, and computer-aided guidance under various medical imaging and
sensing modalities. While these methods may displace some tasks of surgical
teams and individual surgeons, they also present new capabilities in
interventions that are too difficult or go beyond the skills of a human. In
this chapter, we provide an overview of robot autonomy in commercial use and in
research, and present some of the challenges faced in developing autonomous
surgical robots
An overview of artificial intelligence and robotics. Volume 2: Robotics
This report provides an overview of the rapidly changing field of robotics. The report incorporates definitions of the various types of robots, a summary of the basic concepts, utilized in each of the many technical areas, review of the state of the art and statistics of robot manufacture and usage. Particular attention is paid to the status of robot development, the organizations involved, their activities, and their funding
Graduate Course Descriptions, 2006 Winter
Wright State University graduate course descriptions from Winter 2006
Graduate Course Descriptions, 2005 Fall
Wright State University graduate course descriptions from Fall 2005
Mobile Robotics
The book is a collection of ten scholarly articles and reports of experiences and perceptions concerning pedagogical practices with mobile robotics.“This work is funded by CIEd – Research Centre on Education, project UID/CED/01661/2019, Institute of Education, University of Minho, through national funds of FCT/MCTES-PT.
Development and Biomechanical Analysis toward a Mechanically Passive Wearable Shoulder Exoskeleton
Shoulder disability is a prevalent health issue associated with various orthopedic and neurological conditions, like rotator cuff tear and peripheral nerve injury. Many individuals with shoulder disability experience mild to moderate impairment and struggle with elevating the shoulder or holding the arm against gravity. To address this clinical need, I have focused my research on developing wearable passive exoskeletons that provide continuous at-home movement assistance. Through a combination of experiments and computational tools, I aim to optimize the design of these exoskeletons.
In pursuit of this goal, I have designed, fabricated, and preliminarily evaluated a wearable, passive, cam-driven shoulder exoskeleton prototype. Notably, the exoskeleton features a modular spring-cam-wheel module, allowing customizable assistive force to compensate for different proportions of the shoulder elevation moment due to gravity. The results of my research demonstrated that this exoskeleton, providing modest one-fourth gravity moment compensation at the shoulder, can effectively reduce muscle activity, including deltoid and rotator cuff muscles.
One crucial aspect of passive shoulder exoskeleton design is determining the optimal anti-gravity assistance level. I have addressed this challenge using computational tools and found that an assistance level within the range of 20-30% of the maximum gravity torque at the shoulder joint yields superior performance for specific shoulder functional tasks.
When facing a new task dynamic, such as wearing a passive shoulder exoskeleton, the human neuro-musculoskeletal system adapts and modulates limb impedance at the end-limb (i.e., hand) to enhance task stability. I have presented development and validation of a realistic neuromusculoskeletal model of the upper limb that can predict stiffness modulation and motor adaptation in response to newly introduced environments and force fields. Future studies will explore the model\u27s applicability in predicting stiffness modulation for 3D movements in novel environments, such as passive assistive devices\u27 force fields
Medical robots for MRI guided diagnosis and therapy
Magnetic Resonance Imaging (MRI) provides the capability of imaging tissue with fine resolution and
superior soft tissue contrast, when compared with conventional ultrasound and CT imaging, which
makes it an important tool for clinicians to perform more accurate diagnosis and image guided therapy.
Medical robotic devices combining the high resolution anatomical images with real-time navigation, are
ideal for precise and repeatable interventions. Despite these advantages, the MR environment imposes
constraints on mechatronic devices operating within it. This thesis presents a study on the design and
development of robotic systems for particular MR interventions, in which the issue of testing the MR
compatibility of mechatronic components, actuation control, kinematics and workspace analysis, and
mechanical and electrical design of the robot have been investigated. Two types of robotic systems
have therefore been developed and evaluated along the above aspects.
(i) A device for MR guided transrectal prostate biopsy: The system was designed from components
which are proven to be MR compatible, actuated by pneumatic motors and ultrasonic motors, and
tracked by optical position sensors and ducial markers. Clinical trials have been performed with the
device on three patients, and the results reported have demonstrated its capability to perform needle
positioning under MR guidance, with a procedure time of around 40mins and with no compromised
image quality, which achieved our system speci cations.
(ii) Limb positioning devices to facilitate the magic angle effect for diagnosis of tendinous injuries:
Two systems were designed particularly for lower and upper limb positioning, which are actuated and
tracked by the similar methods as the first device. A group of volunteers were recruited to conduct
tests to verify the functionality of the systems. The results demonstrate the clear enhancement of the
image quality with an increase in signal intensity up to 24 times in the tendon tissue caused by the
magic angle effect, showing the feasibility of the proposed devices to be applied in clinical diagnosis
- …