4,562 research outputs found

    The effect of boundary slip on transient non-Newtonian blood flows under pulsatile pressure

    Get PDF
    In this work, we investigate the influence of boundary slip for two pulsatile flow problems. The first problem is considered with the transient axially symmetric flows of fluids through vessels taking into account the Fahraeus-Lindqvist effect. The second problem is on general three-dimensional blood flows in the human right coronary artery. Both analytical and numerical results are presented to show the flow phenomena and the influence of the slip parameter on the flow behaviour

    The effect of boundary slip on the transient pulsatile flow of a modified second-grade fluid

    Get PDF
    We investigate the effect of boundary slip on the transient pulsatile fluid flow through a vessel with body acceleration. The Fahraeus-Lindqvist effect, expressing the fluid behavior near the wall by the Newtonian fluid while in the core by a non-Newtonian fluid, is also taken into account. To describe the non-Newtonian behavior, we use the modified second-grade fluid model in which the viscosity and the normal stresses are represented in terms of the shear rate. The complete set of equations are then established and formulated in a dimensionless form. For a special case of the material parameter, we derive an analytical solution for the problem, while for the general case, we solve the problem numerically. Our subsequent analytical and numerical results show that the slip parameter has a very significant influence on the velocity profile and also on the convergence rate of the numerical solutions

    Unsteady two-layered blood flow through a w-shape stenosed artery using the generalized oldroyd-b fluid model

    Get PDF
    A theoretical study of unsteady two-layered blood flow through a stenosed artery is presented in this article. The geometry of rigid stenosed artery is assumed to be w-shaped. The flow regime is assumed to be laminar, unsteady and uni-directional. The characteristics of blood are modeled by the generalized Oldroyd-B non-Newtonian fluid model in the core region and a Newtonian fluid in the periphery region. The governing partial differential are derived for each region by using mass and momentum conservation equations. In order to facilitate numerical solutions, the derived differential equations are non-dimensionalized. A well-tested explicit finite difference scheme (FDM) which is forward in time and central in space is employed for the solution of nonlinear initial-boundary value problem corresponding to each region. Validation of the FDM computations is achieved with a variational finite element method (FEM) algorithm. The influence of the emerging geometric and rheological parameters on axial velocity, resistance impedance and wall shear stress are displayed graphically. The instantaneous patterns of streamlines are also presented to illustrate the global behavior of blood flow. The simulations are relevant to hemodynamics of small blood vessels and capillary transport wherein rheological effects are dominant

    Physiologically-based testing system for the mechanical characterization of prosthetic vein valves

    Get PDF
    Due to the relatively limited amount of work done to date on developing prosthetic vein (as opposed to cardiac) valves, advances in this topic require progress in three distinct areas: 1) improved device design, 2) relevant device testing conditions, and, 3) appropriate parameters for evaluation of results. It is the purpose of this paper to address two of these issues (#2 and #3) by: 1) performing a study of normal volunteers to quantify the anatomy and hemodynamic features of healthy venous valves, 2) construction of a 2-step, in vitro testing procedure, which simulates both physiologic and postural conditions seen in the lower extremity venous system, and, 3) defining several modified and new parameters which quantify dynamic valve characteristics

    Haemodynamics analysis of carotid artery stenosis and carotid artery stenting

    Get PDF
    Carotid stenosis is a local narrowing of the carotid artery, and is usually found in the internal carotid artery. The presence of a high-degree stenosis in a carotid artery may provoke transition from laminar to turbulent flow during part of the cardiac cycle. Turbulence in blood flow can influence haemodynamic parameters such as velocity profiles, shear stress and pressure, which are important in wall remodelling. Patients with severe stenosis could be treated with a minimally invasive clinical procedure, carotid artery stenting (CAS). Although CAS has been widely adopted in clinical practice, the complication of in-stent restenosis (ISR) has been reported after CAS. The incidence of ISR is influenced by stent characteristics and vessel geometry, and correlates strongly with regions of neointimal hyperplasia (NH). Therefore, the main purpose of this study is to provide more insights into the haemodynamics in stenosed carotid artery and in post-CAS geometries via computational simulation. The first part of the thesis presents a computational study on flow features in a stenotic carotid artery bifurcation using two computational approaches, large eddy simulation (LES) and Reynolds-averaged Navier-Stokes (RANS) incorporating the Shear Stress Transport model with the γ-Reθ transition (SST-Tran) models. The computed flow patterns are compared with those measured with particle image velocimetry (PIV). The results show that both SST-Tran and LES can predict the PIV results reasonably well, but LES is more accurate especially at locations distal to the stenosis where flow is highly disturbed. The second part of the thesis is to determine how stent strut design may influence the development of ISR at the carotid artery bifurcation following CAS. Key parameters that can be indicative of ISR are obtained for different stent designs and compared; these include low and oscillating wall shear stress (WSS), high residence time, and wall stress. A computationally efficient methodology is employed to reproduce stent strut geometry. This method facilitates the accurate reconstruction of actual stent geometry and details of strut configuration and its inclusion in the fluid domain. Computational simulations for flow patterns and low-density lipoprotein (LDL) transport are carried out in order to investigate spatial and temporal variations of WSS and LDL accumulation in the stented carotid geometries. Furthermore, finite element (FE) analysis is performed to evaluate the wall stress distribution with different stent designs. The results reveal that the closed-cell stent design is more likely to create atheroprone and procoagulant flow conditions, causing larger area to be exposed to low wall shear stress (WSS), elevated oscillatory shear index, as well as to induce higher wall stress compared to the open-cell stent design. This study also demonstrates the suitability of SST-Tran and LES models in capturing the presence of complex flow patterns in post-stenotic region.Open Acces

    A Short Review of Advances in the Modelling of Blood Rheology and Clot Formation

    Get PDF
    Several advances have taken place since the early 2000s in the field of blood flow modelling. These advances have been driven by the development of assist devices such as Left Ventricular Assist Devices (LVADs), etc., and by the acceptance of in silico tests for the generation of hypotheses concerning clot formation and lysis. We give an overview of the developments in modelling of blood rheology and clot formation/lysis in the last 10 to 15 years. In blood rheology, advances are increasingly supplemented by flow simulation studies. In clot formation (or coagulation), advances have taken place in both single-scale modeling under quiescent conditions as well as in multi-scale modeling in the presence of flow. The future will possibly see more blood flow simulations in complex geometries and, simultaneously, development and simulation of multi-scale models for clot formation and lysis

    Laboratory Development of a Self-Powered Fontan for Treatment of Congenital Heart Disease

    Get PDF
    Around 8% of all newborns with a Congenital Heart Defect (CHD) have only a single functioning ventricle. The Fontan operation has served as a palliation for this anomaly for decades, but the surgery entails multiple complications and survival rate is less than 50% by adulthood. A rapidly testable novel alternative is proposed by creating a bifurcating graft, or Injection Jet Shunt (IJS), used to “entrain” the pulmonary flow and thus provide assistance while reducing the caval pressure. A benchtop Mock Flow Loop (MFL) is configured to validate this hypothesis. The MFL is based on a Lumped-Parameter Model (LPM) of the Fontan circulation and is comprised of upper and lower systemic as well as left and right pulmonary compartments. Needle valves are used to accurately replicate vascular resistance (R) while compliance chambers are used to mimic vascular compliance values (C). The Fontan MFL is driven with cardiac pulsatility provided by a Harvard Apparatus medical pump. Patient-specific models of the centerpiece of the MFL along with the grafts (IJS) are produced via 3D printing. Baseline values are validated against patient-specific waveforms. Flow and pressure sensor data at specific points in the MFL are acquired via a National Instruments multichannel data acquisition board and processed using LabView. Several IJS nozzle diameters are tested to validate the hypothesis and optimize the improvement

    Peristaltic transport of bi-viscosity fluids through a curved tube : a mathematical model for intestinal flow

    Get PDF
    The human intestinal tract is a long curved tube constituting the final section of the digestive system in which nutrients and water are mostly absorbed. Motivated by the dynamics of chyme in the intestine, a mathematical model is developed to simulate the associated transport phenomena via peristaltic transport. Rheology of chyme is modelled using the Nakamura-Sawada bi-viscosity non-Newtonian formulation. The intestinal tract is considered as a curved tube geometric model. Low Reynolds number (creeping hydrodynamics) and long wavelength approximations are taken into consideration.Analytical solutions of the moving boundary value problem are derived for velocity field,pressure gradient and pressure rise. Streamline flow visualization is achieved with Mathematica symbolic software. Peristaltic pumping phenomenon and trapping of the bolus are also examined. The influence of curvature parameter, apparent viscosity coefficient (rheological parameter) and volumetric flow rate on flow characteristics is described. Validation of analytical solutions is achieved with a MAPLE17 numerical quadrature algorithm. The work is relevant to improving understanding of gastric hydrodynamics and provides a benchmark for further computational fluid dynamics (CFD) simulations

    NASA contributions to - Cardiovascular monitoring

    Get PDF
    NASA contributions to cardiovasular monitorin
    corecore