107 research outputs found

    Proportional EMG Control of Ankle Plantar Flexion in a Powered Transtibial Prosthesis

    Get PDF
    The human calf muscle generates 80% of the mechanical work to walk throughout stance-phase, powered plantar flexion. Powered plantar flexion is not only important for walking energetics, but also to minimize the impact on the leading leg at heel-strike. For unilateral transtibial amputees, it has recently been shown that knee load on the leading, intact limb decreases as powered plantar flexion in the trailing prosthetic ankle increases. Not surprisingly, excessive loads on the leading, intact knee are believed to be causative of knee osteoarthritis, a leading secondary impairment in lowerextremity amputees. In this study, we hypothesize that a transtibial amputee can learn how to control a powered anklefoot prosthesis using a volitional electromyographic (EMG) control to directly modulate ankle powered plantar flexion. We here present preliminary data, and find that an amputee participant is able to modulate toe-off angle, net ankle work and peak power across a broad range of walking speeds by volitionally modulating calf EMG activity. The modulation of these key gait parameters is shown to be comparable to the dynamical response of the same powered prosthesis controlled intrinsically (No EMG), suggesting that transtibial amputees can achieve an adequate level of powered plantar flexion controllability using direct volitional EMG control.United States. Dept. of Defense (award number 6920559)United States. Dept. of Defense (award number 6920877)Swiss National Science Foundation (grant PBELP3_140656

    Volitional control of ankle plantar flexion in a powered transtibial prosthesis during stair-ambulation.

    Get PDF
    Although great advances have been made in the design and control of lower extremity prostheses, walking on different terrains, such as ramps or stairs, and transitioning between these terrains remains a major challenge for the field. In order to generalize biomimetic behaviour of active lower-limb prostheses top-down volitional control is required but has until recently been deemed unfeasible due to the difficulties involved in acquiring an adequate electromyographic (EMG) signal. In this study, we hypothesize that a transtibial amputee can extend the functionality of a hybrid controller, designed for level ground walking, to stair ascent and descent by volitionally modulating powered plantar-flexion of the prosthesis. We here present data illustrating that the participant is able to reproduce ankle push-off behaviour of the intrinsic controller during stair ascent as well as prevent inadvertent push-off during stair descent. Our findings suggest that EMG signal from the residual limb muscles can be used to transition between level-ground walking and stair ascent/descent within a single step and significantly improve prosthesis performance during stair-ambulation

    Within-socket Myoelectric Prediction of Continuous Ankle Kinematics for Control of a Powered Transtibial Prosthesis

    Get PDF
    Objective. Powered robotic prostheses create a need for natural-feeling user interfaces and robust control schemes. Here, we examined the ability of a nonlinear autoregressive model to continuously map the kinematics of a transtibial prosthesis and electromyographic (EMG) activity recorded within socket to the future estimates of the prosthetic ankle angle in three transtibial amputees. Approach. Model performance was examined across subjects during level treadmill ambulation as a function of the size of the EMG sampling window and the temporal \u27prediction\u27 interval between the EMG/kinematic input and the model\u27s estimate of future ankle angle to characterize the trade-off between model error, sampling window and prediction interval. Main results. Across subjects, deviations in the estimated ankle angle from the actual movement were robust to variations in the EMG sampling window and increased systematically with prediction interval. For prediction intervals up to 150 ms, the average error in the model estimate of ankle angle across the gait cycle was less than 6°. EMG contributions to the model prediction varied across subjects but were consistently localized to the transitions to/from single to double limb support and captured variations from the typical ankle kinematics during level walking. Significance. The use of an autoregressive modeling approach to continuously predict joint kinematics using natural residual muscle activity provides opportunities for direct (transparent) control of a prosthetic joint by the user. The model\u27s predictive capability could prove particularly useful for overcoming delays in signal processing and actuation of the prosthesis, providing a more biomimetic ankle response

    Continuous Proportional Myoelectric Control of an Experimental Powered Lower Limb Prosthesis During Walking Using Residual Muscles.

    Full text link
    Current robotic lower limb prostheses rely on intrinsic sensing and finite state machines to control ankle mechanics during walking. State-based controllers are suitable for stereotypical cyclic locomotor tasks (e.g. walking on level ground) where joint mechanics are well defined at specific gait phases (i.e. states) and state transitions are easily detected. However, state-based controllers are not ideal for non-stereotypical acyclic tasks (e.g. freestyle dancing) where joint mechanics cannot be predefined and transitions are unpredictable. An alternative to state-based control is to utilize the amputee's nervous system for myoelectric control. A robotic lower limb prosthesis that uses continuous proportional myoelectric control would allow the amputee to adapt their ankle mechanics freely. One potential source for myoelectric control is the amputee’s residual muscles. I conducted four studies to examine the feasibility of using residual muscles for continuous myoelectric control during walking. In my first study, I demonstrated that it is possible to record residual electromyography from amputees during walking that are viable for continuous myoelectric control. My results showed that the stride-to-stride variability of residual and intact muscle activation patterns was similar. However, residual muscle activation patterns were significantly different across amputee subjects and significantly different than corresponding muscles in intact subjects. In my second study, I built and tested an experimental powered transtibial prosthesis and demonstrated that an amputee subject was able to walk using continuous proportional myoelectric control to alter prosthetic ankle mechanics. In my third study, I showed that five amputee subjects were able to adapt their residual muscles to walk using continuous proportional myoelectric control. With visual feedback of their control signal, amputees were able to generate higher peak ankle power walking with the experimental powered prosthesis compared to their prescribed prosthesis. In my fourth study, I conducted a user experience study and found that despite challenges with the device user interface, walking with continuous proportional myoelectric control gave amputees a sense of empowerment and embodiment. The results of my studies demonstrated the advantages and disadvantages of using continuous proportional myoelectric control for a powered transtibial prosthesis and suggest how next generation prostheses can build upon these findings.PHDBiomedical EngineeringUniversity of Michigan, Horace H. Rackham School of Graduate Studieshttp://deepblue.lib.umich.edu/bitstream/2027.42/110412/1/shuangz_1.pd

    Split-belt adaptation and gait symmetry in transtibial amputees walking with a hybrid EMG controlled ankle-foot prosthesis

    Get PDF
    Our ability to automatically adapt our walking pattern to the demands of our environment is central to maintaining a steady gait. Accordingly, a large effort is being made to extend and integrate this adaptability to lower-limb prostheses. To date, the main focus of this research has been on short term adaptation, such as in response to a terrain transition or a sudden change in the environment. However, long term adaptation and underlying sensorimotor learning processes are critical to optimizing walking patterns and predictively changing our gait when faced with continued perturbations. Furthermore, investigating these processes in lower-limb amputees may provide a unique window into the interplay between sensory driven adaptation and top-down cerebellar modulation of locomotor reflexes and may potentially help alleviate gait asymmetries. In the current exploratory study, we therefore investigated adaptation, sensorimotor learning, and gait symmetry in a group of transtibial amputees walking with a hybrid-EMG controlled powered prosthesis and matched controls (both groups N=3). Participants were asked to perform a split-belt walking trial during which the belt on the affected side ran at twice the speed of the contralateral belt (1.0m/s and 0.5m/s respectively). Adaptation, sensorimotor learning, and symmetry are compared to two baseline conditions. Initial results illustrate that the amputees were readily able to use the hybrid controller, modulated their EMG depending on treadmill speed, and successfully adapted their gait during split-belt walking. However, the temporal gait parameters suggest that amputees used a different adaptation technique and showed reduced sensorimotor learning, while gait symmetry was improved, in the short term, post-adaptation

    EMG-driven control in lower limb prostheses: a topic-based systematic review

    Get PDF
    Background The inability of users to directly and intuitively control their state-of-the-art commercial prosthesis contributes to a low device acceptance rate. Since Electromyography (EMG)-based control has the potential to address those inabilities, research has flourished on investigating its incorporation in microprocessor-controlled lower limb prostheses (MLLPs). However, despite the proposed benefits of doing so, there is no clear explanation regarding the absence of a commercial product, in contrast to their upper limb counterparts. Objective and methodologies This manuscript aims to provide a comparative overview of EMG-driven control methods for MLLPs, to identify their prospects and limitations, and to formulate suggestions on future research and development. This is done by systematically reviewing academical studies on EMG MLLPs. In particular, this review is structured by considering four major topics: (1) type of neuro-control, which discusses methods that allow the nervous system to control prosthetic devices through the muscles; (2) type of EMG-driven controllers, which defines the different classes of EMG controllers proposed in the literature; (3) type of neural input and processing, which describes how EMG-driven controllers are implemented; (4) type of performance assessment, which reports the performance of the current state of the art controllers. Results and conclusions The obtained results show that the lack of quantitative and standardized measures hinders the possibility to analytically compare the performances of different EMG-driven controllers. In relation to this issue, the real efficacy of EMG-driven controllers for MLLPs have yet to be validated. Nevertheless, in anticipation of the development of a standardized approach for validating EMG MLLPs, the literature suggests that combining multiple neuro-controller types has the potential to develop a more seamless and reliable EMG-driven control. This solution has the promise to retain the high performance of the currently employed non-EMG-driven controllers for rhythmic activities such as walking, whilst improving the performance of volitional activities such as task switching or non-repetitive movements. Although EMG-driven controllers suffer from many drawbacks, such as high sensitivity to noise, recent progress in invasive neural interfaces for prosthetic control (bionics) will allow to build a more reliable connection between the user and the MLLPs. Therefore, advancements in powered MLLPs with integrated EMG-driven control have the potential to strongly reduce the effects of psychosomatic conditions and musculoskeletal degenerative pathologies that are currently affecting lower limb amputees

    Electromyography-Based Control of Lower Limb Prostheses: A Systematic Review

    Get PDF
    Most amputations occur in lower limbs and despite improvements in prosthetic technology, no commercially available prosthetic leg uses electromyography (EMG) information as an input for control. Efforts to integrate EMG signals as part of the control strategy have increased in the last decade. In this systematic review, we summarize the research in the field of lower limb prosthetic control using EMG. Four different online databases were searched until June 2022: Web of Science, Scopus, PubMed, and Science Direct. We included articles that reported systems for controlling a prosthetic leg (with an ankle and/or knee actuator) by decoding gait intent using EMG signals alone or in combination with other sensors. A total of 1,331 papers were initially assessed and 121 were finally included in this systematic review. The literature showed that despite the burgeoning interest in research, controlling a leg prosthesis using EMG signals remains challenging. Specifically, regarding EMG signal quality and stability, electrode placement, prosthetic hardware, and control algorithms, all of which need to be more robust for everyday use. In the studies that were investigated, large variations were found between the control methodologies, type of research participant, recording protocols, assessments, and prosthetic hardware

    A Prototype of a Neural, Powered, Transtibial Prosthesis for the Cat: Benchtop Characterization

    Get PDF
    We developed a prototype of a neural, powered, transtibial prosthesis for the use in a feline model of prosthetic gait. The prosthesis was designed for attachment to a percutaneous porous titanium implant integrated with bone, skin, and residual nerves and muscles. In the benchtop testing, the prosthesis was fixed in a testing rig and subjected to rhythmic vertical displacements and interactions with the ground at a cadence corresponding to cat walking. Several prosthesis functions were evaluated. They included sensing ground contact, control of transitions between the finite states of prosthesis loading, and a closed-loop modulation of the linear actuator gain in each loading cycle. The prosthetic design parameters (prosthesis length = 55 mm, mass = 63 g, peak extension moment = 1 Nm) corresponded closely to those of the cat foot-ankle with distal shank and the peak ankle extension moment during level walking. The linear actuator operated the prosthetic ankle joint using inputs emulating myoelectric activity of residual muscles. The linear actuator gain was modulated in each cycle to minimize the difference between the peak of ground reaction forces (GRF) recorded by a ground force sensor and a target force value. The benchtop test results demonstrated a close agreement between the GRF peaks and patterns produced by the prosthesis and by cats during level walking

    EMG control of prosthetic ankle plantar flexion

    Get PDF
    Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Biological Engineering, 2011.Cataloged from PDF version of thesis.Includes bibliographical references (p. 59-60).Similar to biological human ankle, today's commercially available powered ankle-foot prostheses can vary impedance and deliver net positive ankle work. These commercially available prostheses are intrinsically controlled. Users cannot intuitively change ankle controller's behavior to perform movements that are not part of the repetitive walking gait cycle. For example, when transition from level ground walking to descending stairs, user cannot intuitively initiate or control the amount of ankle angle deflexion for a more normative stair descent gait pattern. This paper presents a hybrid controller that adds myoelectric control functionality to an existing intrinsic controller. The system employs input from both mechanical sensors on the ankle as well as myoelectric signals from gastrocnemius muscle of the user. This control scheme lets the user to modulate the gain of command ankle torque upon push off during level ground walking and stair ascent. It also allows the user to interrupt level ground walking control cycle and initiate ankle plantar flexion during stair descent. As a preliminary study, ankle characteristics such as ankle angle and torque were measured and compared to biological ankle characteristics. Results show that the proposed hybrid controller can maintain existing controller's biomimetic characteristics. In addition, it can also recognize to a qualitative extent the intended command torque for ankle push off and user's desire to switch between control modalities for different terrains. The study shows that it is possible and desirable to use neural signals as control signals for prosthetic leg controllers. Keyword: Myoelectric control, powered prosthesis, proportional torque controlby Jing Wang.M.Eng
    • …
    corecore