11,876 research outputs found

    A robot hand testbed designed for enhancing embodiment and functional neurorehabilitation of body schema in subjects with upper limb impairment or loss.

    Get PDF
    Many upper limb amputees experience an incessant, post-amputation "phantom limb pain" and report that their missing limbs feel paralyzed in an uncomfortable posture. One hypothesis is that efferent commands no longer generate expected afferent signals, such as proprioceptive feedback from changes in limb configuration, and that the mismatch of motor commands and visual feedback is interpreted as pain. Non-invasive therapeutic techniques for treating phantom limb pain, such as mirror visual feedback (MVF), rely on visualizations of postural changes. Advances in neural interfaces for artificial sensory feedback now make it possible to combine MVF with a high-tech "rubber hand" illusion, in which subjects develop a sense of embodiment with a fake hand when subjected to congruent visual and somatosensory feedback. We discuss clinical benefits that could arise from the confluence of known concepts such as MVF and the rubber hand illusion, and new technologies such as neural interfaces for sensory feedback and highly sensorized robot hand testbeds, such as the "BairClaw" presented here. Our multi-articulating, anthropomorphic robot testbed can be used to study proprioceptive and tactile sensory stimuli during physical finger-object interactions. Conceived for artificial grasp, manipulation, and haptic exploration, the BairClaw could also be used for future studies on the neurorehabilitation of somatosensory disorders due to upper limb impairment or loss. A remote actuation system enables the modular control of tendon-driven hands. The artificial proprioception system enables direct measurement of joint angles and tendon tensions while temperature, vibration, and skin deformation are provided by a multimodal tactile sensor. The provision of multimodal sensory feedback that is spatiotemporally consistent with commanded actions could lead to benefits such as reduced phantom limb pain, and increased prosthesis use due to improved functionality and reduced cognitive burden

    Myoelectric forearm prostheses: State of the art from a user-centered perspective

    Get PDF
    User acceptance of myoelectric forearm prostheses is currently low. Awkward control, lack of feedback, and difficult training are cited as primary reasons. Recently, researchers have focused on exploiting the new possibilities offered by advancements in prosthetic technology. Alternatively, researchers could focus on prosthesis acceptance by developing functional requirements based on activities users are likely to perform. In this article, we describe the process of determining such requirements and then the application of these requirements to evaluating the state of the art in myoelectric forearm prosthesis research. As part of a needs assessment, a workshop was organized involving clinicians (representing end users), academics, and engineers. The resulting needs included an increased number of functions, lower reaction and execution times, and intuitiveness of both control and feedback systems. Reviewing the state of the art of research in the main prosthetic subsystems (electromyographic [EMG] sensing, control, and feedback) showed that modern research prototypes only partly fulfill the requirements. We found that focus should be on validating EMG-sensing results with patients, improving simultaneous control of wrist movements and grasps, deriving optimal parameters for force and position feedback, and taking into account the psychophysical aspects of feedback, such as intensity perception and spatial acuity

    Human-centered Electric Prosthetic (HELP) Hand

    Get PDF
    Through a partnership with Indian non-profit Bhagwan Mahaveer Viklang Sahayata Samiti, we designed a functional, robust, and and low cost electrically powered prosthetic hand that communicates with unilateral, transradial, urban Indian amputees through a biointerface. The device uses compliant tendon actuation, a small linear servo, and a wearable garment outfitted with flex sensors to produce a device that, once placed inside a prosthetic glove, is anthropomorphic in both look and feel. The prosthesis was developed such that future groups can design for manufacturing and distribution in India

    Numerical simulation of long and slender cylinders vibrating in axial flow applied to the Myrrha reactor

    Get PDF
    Flow induced vibrations are an important concern in the design of nuclear reactors. One of the possible designs of the 4th generation nuclear reactors is a lead-cooled fast reactor of which MYYRHA is a prototype. The combination of high liquid density, flow velocity, low pitch-to-diameter ratio and the absence of grid spacers makes this design prone to flow induced vibrations. Although most vibrations are induced by cross flow, axial flow around this slender structure could also induce vibrations. In order to gain insight in the possible vibrations (either induced by cross flow, axial flow or an external excitation) this study examines the change of eigenmodes and frequencies of a bare rod due to the lead-bismuth flow. To do so partitioned simulations of the fluid structure interaction are performed in which the structure is initially perturbed according to an in-air eigenmode

    Early Development of Total Hip Replacement

    Get PDF
    Annotated and edited transcript of a Witness Seminar held on 14 March 2006. Introduction by Dr Francis Neary and Professor John Pickstone. First published by the Wellcome Trust Centre for the History of Medicine at UCL, 2007. ©The Trustee of the Wellcome Trust, London, 2007. All volumes are freely available online at: www.history.qmul.ac.uk/research/modbiomed/wellcome_witnesses/Annotated and edited transcript of a Witness Seminar held on 14 March 2006. Introduction by Dr Francis Neary and Professor John Pickstone,Annotated and edited transcript of a Witness Seminar held on 14 March 2006. Introduction by Dr Francis Neary and Professor John Pickstone,Annotated and edited transcript of a Witness Seminar held on 14 March 2006. Introduction by Dr Francis Neary and Professor John Pickstone,Annotated and edited transcript of a Witness Seminar held on 14 March 2006. Introduction by Dr Francis Neary and Professor John Pickstone,Annotated and edited transcript of a Witness Seminar held on 14 March 2006. Introduction by Dr Francis Neary and Professor John Pickstone,Annotated and edited transcript of a Witness Seminar held on 14 March 2006. Introduction by Dr Francis Neary and Professor John Pickstone,Total hip replacement effectively began in the UK in 1938 and has led to widely used, commercially successful, mass-produced devices that relieve pain for an ever increasing period. The Witness Seminar, chaired by Mr Alan Lettin, discussed the remarkable postwar collaboration of British surgeons, engineers and manufacturing firms in the development of efficient alloys, surgical procedures, instruments and the implementation of clean, bacteria-reduced air in enclosed operating theatres, as illustrated by successful prostheses and techniques developed in Norwich (Kenneth McKee), Wrightington (Sir John Charnley), Stanmore (John Scales), Redhill (Peter Ring), and Exeter (Robin Ling and Clive Lee). Early failures - such as loosening from infection, osteolysis, and wear debris - stimulated the search for improved materials and fixation methods, as well as the addition of antibiotics to bone cement to reduce infection. National hip registers that record the survival of different implants were adopted in Europe in the 1970s (2003 in the UK), and they pinpoint the successful devices, as measured by survival and low rates of revision. An introduction to the volume by Dr Francis Neary and Professor John Pickstone, and appendices on materials by Professor Alan Swanson; on international standards by Mr Victor Wheble; and of details of selected prosthesis supplement the transcript. Contributors include: Lady Charnley, the late Mr Harry Craven, Mr Graham Deane, Professor Duncan Dowson, Mr Reg Elson, Dr Alex Faulkner, Professor Michael Freeman, Mrs Phyllis Hampson, Mr Kevin Hardinge, Mr Mike Heywood-Waddington, Mr John Kirkup, Mr Krishna (Ravi) Kunzru, Miss Betty Lee, Mr Alan Lettin (chair), Mr John Older, Mr John Read, Mr Peter Ring, Mr Ian Stephen, Mr Malcolm Swann, Professor Alan Swanson, Sir Rodney Sweetnam, Mr Keith Tucker, Mr Victor Wheble and Professor Michael Wroblewski. Reynolds L A, Tansey E M. (eds) (2007) Early development of total hip replacement, Wellcome Witnesses to Twentieth Century Medicine, vol. 29. London: The Wellcome Trust Centre for the History of Medicine at UCL.The Wellcome Trust Centre for the History of Medicine at UCL is funded by the Wellcome Trust, which is a registered charity, no. 210183

    Keratoprostheses for corneal blindness: a review of contemporary devices

    Get PDF
    According to the World Health Organization, globally 4.9 million are blind due to corneal pathology. Corneal transplantation is successful and curative of the blindness for a majority of these cases. However, it is less successful in a number of diseases that produce corneal neovascularization, dry ocular surface and recurrent inflammation, or infections. A keratoprosthesis or KPro is the only alternative to restore vision when corneal graft is a doomed failure. Although a number of KPros have been proposed, only two devices, Boston type-1 KPro and osteo-odonto-KPro, have came to the fore. The former is totally synthetic and the latter is semi-biological in constitution. These two KPros have different surgical techniques and indications. Keratoprosthetic surgery is complex and should only be undertaken in specialized centers, where expertise, multidisciplinary teams, and resources are available. In this article, we briefly discuss some of the prominent historical KPros and contemporary devices

    New developments in prosthetic arm systems

    Get PDF
    Absence of an upper limb leads to severe impairments in everyday life, which can further influence the social and mental state. For these reasons, early developments in cosmetic and body-driven prostheses date some centuries ago, and they have been evolving ever since. Following the end of the Second World War, rapid developments in technology resulted in powered myoelectric hand prosthetics. In the years to come, these devices were common on the market, though they still suffered high user abandonment rates. The reasons for rejection were trifold - insufficient functionality of the hardware, fragile design, and cumbersome control. In the last decade, both academia and industry have reached major improvements concerning technical features of upper limb prosthetics and methods for their interfacing and control. Advanced robotic hands are offered by several vendors and research groups, with a variety of active and passive wrist options that can be articulated across several degrees of freedom. Nowadays, elbow joint designs include active solutions with different weight and power options. Control features are getting progressively more sophisticated, offering options for multiple sensor integration and multi-joint articulation. Latest developments in socket designs are capable of facilitating implantable and multiple surface electromyography sensors in both traditional and osseointegration-based systems. Novel surgical techniques in combination with modern, sophisticated hardware are enabling restoration of dexterous upper limb functionality. This article is aimed at reviewing the latest state of the upper limb prosthetic market, offering insights on the accompanying technologies and techniques. We also examine the capabilities and features of some of academia’s flagship solutions and methods

    Modelling mitral valvular dynamics–current trend and future directions

    Get PDF
    Dysfunction of mitral valve causes morbidity and premature mortality and remains a leading medical problem worldwide. Computational modelling aims to understand the biomechanics of human mitral valve and could lead to the development of new treatment, prevention and diagnosis of mitral valve diseases. Compared with the aortic valve, the mitral valve has been much less studied owing to its highly complex structure and strong interaction with the blood flow and the ventricles. However, the interest in mitral valve modelling is growing, and the sophistication level is increasing with the advanced development of computational technology and imaging tools. This review summarises the state-of-the-art modelling of the mitral valve, including static and dynamics models, models with fluid-structure interaction, and models with the left ventricle interaction. Challenges and future directions are also discussed
    corecore