Efficient solid state power amplifiers: power combining and highly accurate AM/AM and AM/PM behavioural models with application to linearisation
Radio Frequency (RF) Power Amplifiers (PAs) are a major contributor to modern communication
systems, both in terms of being an enabling technology as well as having
the most impact on overall system availability, linearity and power consumption. In
order to achieve the most optimum system outcome there needs to be an appropriate
method for selecting the most suitable RF PA design approach, as well as being able to
select the most appropriate RF PA output device, based on a range of varying requirements,
specifications and technologies. The ability to perform these tasks quickly, with
improved accuracy, using existing available device data, with minimal or no further
device testing and from a range of existing and emerging technologies would provide
RF PA designers with significant benefits.
The investigations and research provided in this thesis consider a range of existing and
emerging RF PA technologies and power combining methods and compares them via
a new selection and design methodology developed in this thesis. The new methodology
builds on modern design and statistical approaches including manufacturing
options that enable an appropriate technology to be selected for Solid State Power Amplifier
(SSPA) design. In addition to hard design specifications, the current thesis also
considers less tangible specifications, such as graceful degradation, time tomarket and
ease of use, as well as alternative design approaches, such as fuzzy logic approaches.
With a suitable technology approach determined, a selection of a suitable RF output
device(s) is considered. As the demand for new communication services continues
to increase, requiring tighter specifications and reduced product delivery time scales,
then the ability to accurately and quickly compare available RF PA devices from a
range of device technologies or devices from different manufacturers, at both the system
and component level, makes such a selection paramount. In this thesis, simplememoryless
(AmplitudeModulation/AmplitudeModulation (AM/AM) only) and
Quasi-Memoryless (QM) Behavioural Models (BMs) (AM/AM combined with Amplitude
Modulation/Phase Modulation (AM/PM)) are reviewed, extended and improved
upon, with up to 20 dB Normalised Mean Squared Error (NMSE) modelling
improvement achieved over a range of technologies, allowing effective RF PA device selection using these newly developed simple and fast models. This thesis uses recent
existing accurate and powerful semi-physical memoryless BMs, suited to RF PA
devices, and develops and extends their use for QM modelling. The trade-off from
the improvement in the overall accuracy is some further simple processing steps. Furthermore,
this thesis also provides a comparison of other models, presented in the
literature. The improved simple RF PA device models and extension techniques presented
in this thesis show, via simulation and measurement, that the new models are
suitable for use over a wide range. Lineariser improvements, linked to the accuracy
improvements of the proposed models of this thesis, are also investigated, showing
further benefits from this research.
Physically based simple QM BMs are also used to model thermal and bias network
memory effects, which are becomingmore relevant tomodern communication services
that use wider bandwidths, enabling the impacts of RF PA device memory effects to be
determined and compared.
The feasibility of the developed models and improvements are also utilised in the simulation
of a low cost RF PA lineariser. With the trend to smaller localised low cost
and power RF mobile wireless repeater cells being away from larger more expensive
and complex hardware, used to perform linearisation, this thesis presents a trade-off
between complexity and linearisation performance and demonstrates, through modelling
and simulation, that 8-10 dB improvement in linearisation performance is achievable
with the use of the newly developed models.Thesis (Ph.D.) -- University of Adelaide, School of Electrical and Electronic Engineering, 201
Amplitude and phase sonar calibration and the use of target phase for enhanced acoustic target characterisation
This thesis investigates the incorporation of target phase into sonar signal processing, for enhanced information in the context of acoustical oceanography. A sonar system phase calibration method, which includes both the amplitude and phase response is proposed. The technique is an extension of the widespread standard-target sonar calibration method, based on the use of metallic spheres as standard targets. Frequency domain data processing is used, with target phase measured as a phase angle difference between two frequency components. This approach minimizes the impact of range uncertainties in the calibration process. Calibration accuracy is examined by comparison to theoretical full-wave modal solutions. The system complex response is obtained for an operating frequency of 50 to 150 kHz, and sources of ambiguity are examined. The calibrated broadband sonar system is then used to study the complex scattering of objects important for the modelling of marine organism echoes, such as elastic spheres, fluid-filled shells, cylinders and prolate spheroids. Underlying echo formation mechanisms and their interaction are explored. Phase-sensitive sonar systems could be important for the acquisition of increased levels of information, crucial for the development of automated species identification. Studies of sonar system phase calibration and complex scattering from fundamental shapes are necessary in order to incorporate this type of fully-coherent processing into scientific acoustic instruments
Analog dithering techniques for highly linear and efficient transmitters
The current thesis is about investigation of new methods and techniques to be able to utilize the switched mode amplifiers, for linear and efficient applications. Switched mode amplifiers benefit from low overlap between the current and voltage wave forms in their output terminals, but they seriously suffer from nonlinearity. This makes it impossible to use them to amplify non-constant envelope message signals, where very high linearity is expected. In order to do that, dithering techniques are studied and a full linearity analysis approach is developed, by which the linearity performance of the dithered amplifier can be analyzed, based on the dithering level and frequency. The approach was based on orthogonalization of the equivalent nonlinearity and is capable of prediction of both co-channel and adjacent channel nonlinearity metrics, for a Gaussian complex or real input random signal. Behavioral switched mode amplifier models are studied and new models are developed, which can be utilized to predict the nonlinear performance of the dithered power amplifier, including the nonlinear capacitors effects. For HFD application, self-oscillating and asynchronous sigma delta techniques are currently used, as pulse with modulators (PWM), to encode a generic RF message signal, on the duty cycle of an output pulse train. The proposed models and analysis techniques were applied to this architecture in the first phase, and the method was validated with measurement on a prototype sample, realized in 65 nm TSMC CMOS technology. Afterwards, based on the same dithering phenomenon, a new linearization technique was proposed, which linearizes the switched mode class D amplifier, and at the same time can reduce the reactive power loss of the amplifier. This method is based on the dithering of the switched mode amplifier with frequencies lower than the band-pass message signal and is called low frequency dithering (LFD). To test this new technique, two test circuits were realized and the idea was applied to them. Both of the circuits were of the hard nonlinear type (class D) and are integrated CMOS and discrete LDMOS technologies respectively. The idea was successfully tested on both test circuits and all of the linearity metric predictions for a digitally modulated RF signal and a random signal were compared to the measurements. Moreover a search method to find the optimum dither frequency was proposed and validated. Finally, inspired by averaging interpretation of the dithering phenomenon, three new topologies were proposed, which are namely DLM, RF-ADC and area modulation power combining, which are all nonlinear systems linearized with dithering techniques. A new averaging method was developed and used for analysis of a Gilbert cell mixer topology, which resulted in a closed form relationship for the conversion gain, for long channel devices
Wired, wireless and wearable bioinstrumentation for high-precision recording of bioelectrical signals in bidirectional neural interfaces
It is widely accepted by the scientific community that bioelectrical signals, which can be used for the identification of neurophysiological biomarkers indicative of a diseased or pathological state, could direct patient treatment towards more effective therapeutic strategies. However, the design and realisation of an instrument that can precisely record weak bioelectrical signals in the presence of strong interference stemming from a noisy clinical environment is one of the most difficult challenges associated with the strategy of monitoring bioelectrical signals for diagnostic purposes. Moreover, since patients often have to cope with the problem of limited mobility being connected to bulky and mains-powered instruments, there is a growing demand for small-sized, high-performance and ambulatory biopotential acquisition systems in the Intensive Care Unit (ICU) and in High-dependency wards.
Furthermore, electrical stimulation of specific target brain regions has been shown to alleviate symptoms of neurological disorders, such as Parkinson’s disease, essential tremor, dystonia, epilepsy etc. In recent years, the traditional practice of continuously stimulating the brain using static stimulation parameters has shifted to the use of disease biomarkers to determine the intensity and timing of stimulation. The main motivation behind closed-loop stimulation is minimization of treatment side effects by providing only the necessary stimulation required within a certain period of time, as determined from a guiding biomarker. Hence, it is clear that high-quality recording of local field potentials (LFPs) or electrocorticographic (ECoG) signals during deep brain stimulation (DBS) is necessary to investigate the instantaneous brain response to stimulation, minimize time delays for closed-loop neurostimulation and maximise the available neural data.
To our knowledge, there are no commercial, small, battery-powered, wearable and wireless recording-only instruments that claim the capability of recording ECoG signals, which are of particular importance in closed-loop DBS and epilepsy DBS. In addition, existing recording systems lack the ability to provide artefact-free high-frequency (> 100 Hz) LFP recordings during DBS in real time primarily because of the contamination of the neural signals of interest by the stimulation artefacts.
To address the problem of limited mobility often encountered by patients in the clinic and to provide a wide variety of high-precision sensor data to a closed-loop neurostimulation platform, a low-noise (8 nV/√Hz), eight-channel, battery-powered, wearable and wireless multi-instrument (55 × 80 mm2) was designed and developed. The performance of the realised instrument was assessed by conducting both ex vivo and in vivo experiments. The combination of desirable features and capabilities of this instrument, namely its small size (~one business card), its enhanced recording capabilities, its increased processing capabilities, its manufacturability (since it was designed using discrete off-the-shelf components), the wide bandwidth it offers (0.5 – 500 Hz) and the plurality of bioelectrical signals it can precisely record, render it a versatile tool to be utilized in a wide range of applications and environments.
Moreover, in order to offer the capability of sensing and stimulating via the same electrode, novel real-time artefact suppression methods that could be used in bidirectional (recording and stimulation) system architectures are proposed and validated. More specifically, a novel, low-noise and versatile analog front-end (AFE), which uses a high-order (8th) analog Chebyshev notch filter to suppress the artefacts originating from the stimulation frequency, is presented. After defining the system requirements for concurrent LFP recording and DBS artefact suppression, the performance of the realised AFE is assessed by conducting both in vitro and in vivo experiments using unipolar and bipolar DBS (monophasic pulses, amplitude ranging from 3 to 6 V peak-to-peak, frequency 140 Hz and pulse width 100 µs). Under both in vitro and in vivo experimental conditions, the proposed AFE provided real-time, low-noise and artefact-free LFP recordings (in the frequency range 0.5 – 250 Hz) during stimulation. Finally, a family of tunable hardware filter designs and a novel method for real-time artefact suppression that enables wide-bandwidth biosignal recordings during stimulation are also presented. This work paves the way for the development of miniaturized research tools for closed-loop neuromodulation that use a wide variety of bioelectrical signals as control signals.Open Acces
Recommended from our members
Proposed automobile steering wheel test method for vibration
This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University.This thesis proposes a test method for evaluating the perceived vibration which occurs at the driver's hand in automotive steering wheel interface. The objective of the research was to develop frequency weightings for quantifying the human perception of steering wheel hand-arm vibration. Family of frequency weightings were developed from equal sensation curves obtained from the psychophysical laboratory experimental tests.
The previous literature suggests that the only internationally standardised frequency weighting Wh is not accurate to predict human perception of steering wheel hand-arm vibration (Amman et. al, 2005) because Wh was developed originally for health effects, not for the human perception. In addition, most of the data in hand-arm vibration are based upon responses from male subjects (Neely and Burström, 2006) and previous studies based only on sinusoidal stimuli. Further, it has been continuously suggested by researchers (Gnanasekarna et al., 2006; Morioka and Griffin, 2006; Ajovalasit and Giacomin, 2009) that only one weighting is not optimal to estimate the human perception at all vibrational magnitudes.
In order to address these problems, the investigation of the effect of gender, body mass and the signal type on the equal sensation curves has been performed by means of psychophysical laboratory experimental tests. The test participants were seated on a steering wheel simulator which consists of a rigid frame, a rigid steering wheel, an automobile seat, an electrodynamic shaker unit, a power amplifier and a signal generator. The category-ratio Borg CR10 scale procedure was used to quantify the perceived vibration intensity. A same test protocol was used for each test and for each test subject.
The first experiment was conducted to investigate the effect of gender using sinusoidal vibration with 40 test participants (20 males and 20 females). The results suggested that the male participants provided generally lower subjective ratings than the female participants. The second experiment was conducted using band-limited random vibration to investigate the effect of signal type between sinusoidal and band-limited random vibration with 30 test participants (15 males and 15 females). The results suggested that the equal sensation curves obtained using random vibration were generally steeper and deeper in the shape of the curves than those obtained using sinusoidal vibration. These differences may be due to the characteristics of random vibration which produce generally higher crest factors than sinusoidal vibration. The third experiment was conducted to investigate the effect of physical body mass with 40 test participants (20 light and 20 heavy participants) using sinusoidal vibration. The results suggested that the light participants produced generally higher subjective ratings than the heavy participants. From the results it can be suggested that the equal sensation curves for steering wheel rotational vibration differ mainly due to differences of body size rather than differences of gender. The final experiments was conducted using real road signals to quantify the human subjective response to representative driving condition and to use the results to define the selection method for choosing the adequate frequency weightings for the road signals by means of correlation analysis. The final experiment was performed with 40 test participants (20 light and 20 heavy participants) using 21 real road signals obtained from the road tests. From the results the hypothesis was established that different amplitude groups may require different frequency weightings. Three amplitude groups were defined and the frequency weightings were selected for each amplitude group.
The following findings can be drawn from the research:
• the equal sensation curves suggest a nonlinear dependency on both the frequency and the amplitude.
• the subjective responses obtained from band-limited random stimuli were steeper and the deeper in the shape of the equal sensation curves than those obtained using sinusoidal vibration stimuli.
• females provided higher perceived intensity values than the males for the same physical stimulus at most frequencies.
• light test participants provided higher perceived intensity than the heavy test participants for the same physical stimulus at most frequencies.
• the equal sensation curves for steering wheel rotational vibration differ mainly due to differences in body size, rather than differences of gender.
• at least three frequency weightings may be necessary to estimate the subjective intensity for road surface stimuli
On-line measurement of partial discharges in high voltage rotating machines.
The on-line condition monitoring of rotating machines is given paramount importance, particularly in Oils and Gas industries where the financial implications of machine shutdown is very high. This project work was directed towards the on-line condition monitoring of high voltage rotating machines by detection of partial discharges (PD) which are indicative of stator insulation degradation. Partial discharge manifests itself in various forms which can be detected using various electrical and non-electrical techniques. The electrical method of detecting small current pulses generated by PD using a Rogowski coil as a sensor has been investigated in this work. Dowding & Mills, who are commercially involved in the condition monitoring of rotating machines, currently use a system called StatorMonotor® for PD detection. The research is intended to develop a new partial discharge detection system that will replace the existing system which is getting obsolete. A three phase partial discharge detection unit was specified, designed and developed that is capable of filtering, amplifying and digitising the discharge signals. The associated data acquisition software was developed using LabVIEW software that was capable of acquiring, displaying and storing the discharge signals. Additional software programs were devised to investigate the removal of external noise. A data compression algorithm was developed to store the discharge data in an efficient manner; also ensuring the backward compatibility to the existing analysis software. Tests were performed in laboratory and on machines on-site and the results are presented. Finally, the data acquisition (DAQ) cards that used the PCMCIA bus was replaced with new USB based DAQ cards with the software modified accordingly. The three phase data acquisition unit developed as a result of this project has produced encouraging results and will be implemented in an industrial environment to evaluate and benchmark its performance with the existing system. Most importantly, a hardware data acquisition platform for the detection of PD pulses has been established within the company which is easily maintainable and expandable to suit any future requirements
Dirty RF Signal Processing for Mitigation of Receiver Front-end Non-linearity
Moderne drahtlose Kommunikationssysteme stellen hohe und teilweise
gegensätzliche Anforderungen an die Hardware der Funkmodule, wie z.B.
niedriger Energieverbrauch, große Bandbreite und hohe Linearität. Die
Gewährleistung einer ausreichenden Linearität ist, neben anderen analogen
Parametern, eine Herausforderung im praktischen Design der Funkmodule. Der
Fokus der Dissertation liegt auf breitbandigen HF-Frontends für
Software-konfigurierbare Funkmodule, die seit einigen Jahren kommerziell
verfügbar sind. Die praktischen Herausforderungen und Grenzen solcher
flexiblen Funkmodule offenbaren sich vor allem im realen Experiment. Eines
der Hauptprobleme ist die Sicherstellung einer ausreichenden analogen
Performanz über einen weiten Frequenzbereich. Aus einer Vielzahl an
analogen Störeffekten behandelt die Arbeit die Analyse und Minderung von
Nichtlinearitäten in Empfängern mit direkt-umsetzender Architektur. Im
Vordergrund stehen dabei Signalverarbeitungsstrategien zur Minderung
nichtlinear verursachter Interferenz - ein Algorithmus, der besser unter
"Dirty RF"-Techniken bekannt ist. Ein digitales Verfahren nach der
Vorwärtskopplung wird durch intensive Simulationen, Messungen und
Implementierung in realer Hardware verifiziert. Um die Lücken zwischen
Theorie und praktischer Anwendbarkeit zu schließen und das Verfahren in
reale Funkmodule zu integrieren, werden verschiedene Untersuchungen
durchgeführt. Hierzu wird ein erweitertes Verhaltensmodell entwickelt, das
die Struktur direkt-umsetzender Empfänger am besten nachbildet und damit
alle Verzerrungen im HF- und Basisband erfasst. Darüber hinaus wird die
Leistungsfähigkeit des Algorithmus unter realen Funkkanal-Bedingungen
untersucht. Zusätzlich folgt die Vorstellung einer ressourceneffizienten
Echtzeit-Implementierung des Verfahrens auf einem FPGA. Abschließend
diskutiert die Arbeit verschiedene Anwendungsfelder, darunter spektrales
Sensing, robuster GSM-Empfang und GSM-basiertes Passivradar. Es wird
gezeigt, dass nichtlineare Verzerrungen erfolgreich in der digitalen
Domäne gemindert werden können, wodurch die Bitfehlerrate gestörter
modulierter Signale sinkt und der Anteil nichtlinear verursachter
Interferenz minimiert wird. Schließlich kann durch das Verfahren die
effektive Linearität des HF-Frontends stark erhöht werden. Damit wird der
zuverlässige Betrieb eines einfachen Funkmoduls unter dem Einfluss der
Empfängernichtlinearität möglich. Aufgrund des flexiblen Designs ist der
Algorithmus für breitbandige Empfänger universal einsetzbar und ist nicht
auf Software-konfigurierbare Funkmodule beschränkt.Today's wireless communication systems place high requirements on the
radio's hardware that are largely mutually exclusive, such as low power
consumption, wide bandwidth, and high linearity. Achieving a sufficient
linearity, among other analogue characteristics, is a challenging issue in
practical transceiver design. The focus of this thesis is on wideband
receiver RF front-ends for software defined radio technology, which became
commercially available in the recent years. Practical challenges and
limitations are being revealed in real-world experiments with these radios.
One of the main problems is to ensure a sufficient RF performance of the
front-end over a wide bandwidth. The thesis covers the analysis and
mitigation of receiver non-linearity of typical direct-conversion receiver
architectures, among other RF impairments. The main focus is on DSP-based
algorithms for mitigating non-linearly induced interference, an approach
also known as "Dirty RF" signal processing techniques. The conceived
digital feedforward mitigation algorithm is verified through extensive
simulations, RF measurements, and implementation in real hardware. Various
studies are carried out that bridge the gap between theory and practical
applicability of this approach, especially with the aim of integrating that
technique into real devices. To this end, an advanced baseband behavioural
model is developed that matches to direct-conversion receiver architectures
as close as possible, and thus considers all generated distortions at RF
and baseband. In addition, the algorithm's performance is verified under
challenging fading conditions. Moreover, the thesis presents a
resource-efficient real-time implementation of the proposed solution on an
FPGA. Finally, different use cases are covered in the thesis that includes
spectrum monitoring or sensing, GSM downlink reception, and GSM-based
passive radar. It is shown that non-linear distortions can be successfully
mitigated at system level in the digital domain, thereby decreasing the bit
error rate of distorted modulated signals and reducing the amount of
non-linearly induced interference. Finally, the effective linearity of the
front-end is increased substantially. Thus, the proper operation of a
low-cost radio under presence of receiver non-linearity is possible. Due to
the flexible design, the algorithm is generally applicable for wideband
receivers and is not restricted to software defined radios
- …