Robust energy disaggregation using appliance-specific temporal contextual information
An extension of the baseline non-intrusive load monitoring approach for energy disaggregation using temporal contextual information is presented in this paper. In detail, the proposed approach uses a two-stage disaggregation methodology with appliance-specific temporal contextual information in order to capture time-varying power consumption patterns in low-frequency datasets. The proposed methodology was evaluated using datasets of different sampling frequency, number and type of appliances. When employing appliance-specific temporal contextual information, an improvement of 1.5% up to 7.3% was observed. With the two-stage disaggregation architecture and using appliance-specific temporal contextual information, the overall energy disaggregation accuracy was further improved across all evaluated datasets with the maximum observed improvement, in terms of absolute increase of accuracy, being equal to 6.8%, thus resulting in a maximum total energy disaggregation accuracy improvement equal to 10.0%.Peer reviewedFinal Published versio
NILM techniques for intelligent home energy management and ambient assisted living: a review
The ongoing deployment of smart meters and different commercial devices has made electricity disaggregation feasible in buildings and households, based on a single measure of the current and, sometimes, of the voltage. Energy disaggregation is intended to separate the total power consumption into specific appliance loads, which can be achieved by applying Non-Intrusive Load Monitoring (NILM) techniques with a minimum invasion of privacy. NILM techniques are becoming more and more widespread in recent years, as a consequence of the interest companies and consumers have in efficient energy consumption and management. This work presents a detailed review of NILM methods, focusing particularly on recent proposals and their applications, particularly in the areas of Home Energy Management Systems (HEMS) and Ambient Assisted Living (AAL), where the ability to determine the on/off status of certain devices can provide key information for making further decisions. As well as complementing previous reviews on the NILM field and providing a discussion of the applications of NILM in HEMS and AAL, this paper provides guidelines for future research in these topics.Agência financiadora:
Programa Operacional Portugal 2020 and Programa Operacional Regional do Algarve
01/SAICT/2018/39578
Fundação para a Ciência e Tecnologia through IDMEC, under LAETA:
SFRH/BSAB/142998/2018
SFRH/BSAB/142997/2018
UID/EMS/50022/2019
Junta de Comunidades de Castilla-La-Mancha, Spain:
SBPLY/17/180501/000392
Spanish Ministry of Economy, Industry and Competitiveness (SOC-PLC project):
TEC2015-64835-C3-2-R MINECO/FEDERinfo:eu-repo/semantics/publishedVersio
Energy Disaggregation Using Elastic Matching Algorithms
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/)In this article an energy disaggregation architecture using elastic matching algorithms is presented. The architecture uses a database of reference energy consumption signatures and compares them with incoming energy consumption frames using template matching. In contrast to machine learning-based approaches which require significant amount of data to train a model, elastic matching-based approaches do not have a model training process but perform recognition using template matching. Five different elastic matching algorithms were evaluated across different datasets and the experimental results showed that the minimum variance matching algorithm outperforms all other evaluated matching algorithms. The best performing minimum variance matching algorithm improved the energy disaggregation accuracy by 2.7% when compared to the baseline dynamic time warping algorithm.Peer reviewedFinal Published versio
Load Demand Disaggregation Based on Simple Load Signature and User's Feedback
Abstract A detailed and on-line knowledge of the electrical load demand by the users is a critical issue for an effective and responsive deployment of home/building energy management. An approach based on the application of Non Intrusive Appliance Load Monitoring (NIALM) techniques copes with the goal of disaggregating composite loads; but to get a high level of precision, NIALM algorithms need a complete load signature and complex optimization algorithms to find the right combination of single loads that fits the real electrical measurements. On the other hand, it is practically impossible to get the detailed signature of all appliances inside a house/building and sophisticated optimization algorithm are not suitable for on-line applications. To overcome such problems a straightforward NIALM algorithm is proposed, it is based on both a simple load signature, rated active and reactive power and a heuristic disaggregation algorithm. Of course, it is expected that on real applications, this approach cannot reach very high performances; this is the reason why an active involvement of users is considered. The users' feedback aims to: correct the load signatures, reduce the error of disaggregation algorithm and increase the active participation of users in saving energy politics. The NIALM algorithm has been accurately tested numerically using as input load curves generated randomly but under given constraints. In this way, the causes of inefficiency of the proposed approach are quantitatively analyzed both separately and in different combinations. Finally, the increase of the efficiency of the NIALM algorithm due to the application of different feedback actions is evaluated and discussed
Integration of Legacy Appliances into Home Energy Management Systems
The progressive installation of renewable energy sources requires the
coordination of energy consuming devices. At consumer level, this coordination
can be done by a home energy management system (HEMS). Interoperability issues
need to be solved among smart appliances as well as between smart and
non-smart, i.e., legacy devices. We expect current standardization efforts to
soon provide technologies to design smart appliances in order to cope with the
current interoperability issues. Nevertheless, common electrical devices affect
energy consumption significantly and therefore deserve consideration within
energy management applications. This paper discusses the integration of smart
and legacy devices into a generic system architecture and, subsequently,
elaborates the requirements and components which are necessary to realize such
an architecture including an application of load detection for the
identification of running loads and their integration into existing HEM
systems. We assess the feasibility of such an approach with a case study based
on a measurement campaign on real households. We show how the information of
detected appliances can be extracted in order to create device profiles
allowing for their integration and management within a HEMS
- …