1,164 research outputs found

    The Effect of Body Weight Support on Squat Biomechanics

    Get PDF
    Syed, Najam. MSME, Purdue University, December 2015. The Effect of Body Weight Support on Squat Biomechanics. Major Professor: Justin Seipel, School of Mechanical Engineering

    Evaluation of a Soft Robotic Knee Exosuit for Assistance in Stair Ascent

    Get PDF
    abstract: Muscular weakness is a common manifestation for Stroke survivors and for patients with Anterior Cruciate Ligament reconstruction leading to reduced functional independence, especially mobility. Several rigid orthotic devices are being designed to assist mobility. However, limitations in majority of these devices are: 1) that they are constrained only to level walking applications, 2) are mostly bulky and rigid lacking user comfort. For these reasons, rehabilitation using soft-robotics can serve as a powerful modality in gait assistance and potentially accelerate functional recovery. The characteristics of soft robotic exosuit is that it’s more flexible, delivers high power to weight ratio, and conforms with the user’s body structure making it a suitable choice. This work explores the implementation of an existing soft robotic exosuit in assisting knee joint mechanism during stair ascent for patients with muscular weakness. The exosuit assists by compensating the lack of joint moment and minimizing the load on the affected limb. It consists of two I-cross-section soft pneumatic actuators encased within a sleeve along with insole sensor shoes and control electronics. The exosuit actuators were mechanically characterized at different angles, in accordance to knee flexion in stair gait, to enable the generation of the desired joint moments. A linear relation between the actuator stiffness and internal pressure as a function of the knee angle was obtained. Results from this characterization along with the insole sensor outputs were used to provide assistance to the knee joint. Analysis of stair gait with and without the exosuit ‘active’ was performed, using surface electromyography (sEMG) sensors, for two healthy participants at a slow walking speed. Preliminary user testing with the exosuit presented a promising 16% reduction in average muscular activity of Vastus Lateralis muscle and a 3.6% reduction on Gluteus Maximus muscle during the stance phase and unrestrained motion during the swing phase of ascent thereby demonstrating the applicability of the soft-inflatable exosuit in rehabilitation.Dissertation/ThesisMasters Thesis Biomedical Engineering 201

    Design of a wearable active ankle-foot orthosis for both sides

    Get PDF
    Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Biomateriais, Reabilitação e Biomecânica)Portugal is the west European country with the highest rate of stroke-related mortality, being that, of those who suffer cerebrovascular accidents, 40% feature an impairment which can manifest itself through motor sequelae, namely drop foot. An ankle-foot orthosis is often recommended to passively accommodate these motor problems; however, active/powered exoskeletons are also a suitable solution for post-stroke patients. Due to the high complexity of the human ankle joint, one of the problems regarding these active devices is the misalignment occurring between the rehabilitation device and the human joint, which is a cause of parasitic forces, discomfort, and pain. The present master dissertation proposes the development of an adjustable wearable active ankle-foot orthosis that is able to tackle this misalignment issue concerning commercially available lower limb orthotic devices. This work is integrated on the SmartOs – Smart, Stand-alone Active Orthotic System – project that proposes an innovative robotic technology (a wearable mobile lab) oriented to gait rehabilitation. The conceptual design of a standard version of the SmartOs wearable active orthosis was initiated with the analysis of another ankle-foot orthosis – Exo-H2 (Technaid) – from which the necessary design changes were implemented, aiming at the improvement of the established device. In order to achieve a conceptual solution, both the practical knowledge of the Orthos XXI design team and several design methods were used to ensure the accomplishment of the defined requirements. The detailed design process of the standard SmartOs wearable active orthosis prototype is disclosed. With the purpose of validating the design, the critical components were simulated with the resources available in SolidWorks®, and the necessary CAD model’s adaptations were implemented to guarantee a reliable and safe design. The presented design is currently set for further production in Orthos XXI, followed by the mandatory mechanical tests.Portugal é o país da Europa ocidental com maior taxa de mortalidade por acidente vascular cerebral (AVC), sendo que, dos que sofrem acidentes vasculares cerebrais, 40% apresentam uma deficiência que pode manifestar-se por sequelas motoras, nomeadamente o pé pendente. Uma ortótese do tornozelo é recomendada frequentemente para acomodar passivamente esses problemas motores; no entanto, exoesqueletos ativos são também uma solução adequada para pacientes pós-AVC. Devido à alta complexidade da articulação do tornozelo humano, um dos problemas associados a esses dispositivos ativos é o desalinhamento que ocorre entre o dispositivo de reabilitação e a articulação humana, que é uma causa de forças parasitas, desconforto e dor. A presente dissertação de mestrado propõe o desenvolvimento de uma ortótese ativa do tornozelo ajustável e vestível, que seja capaz de resolver esse problema de desalinhamento relativo aos dispositivos ortóticos de membros inferiores disponíveis comercialmente. Este trabalho está integrado no projeto SmartOs - Smart, Stand-alone Active Orthotic System - projeto que propõe uma tecnologia robótica inovadora (wearable mobile lab) direcionada para a reabilitação da marcha. O projeto conceptual de uma versão padrão da ortótese ativa vestível do projeto SmartOs foi iniciado com a análise de outra ortótese do tornozelo – Exo-H2 (Technaid) - a partir da qual foram implementadas as alterações de projeto necessárias, visando o aprimoramento do dispositivo estabelecido. Para se chegar a uma solução conceptual, tanto o conhecimento prático da equipa de projeto da Orthos XXI como os diversos métodos de projeto foram utilizados para garantir o cumprimento dos requisitos definidos. O processo do desenho detalhado da versão padrão da ortótese ativa SmartOs será também divulgado. Com o objetivo de validar o projeto, os componentes críticos foram simulados com os recursos disponíveis no SolidWorks® e as adaptações necessárias do modelo CAD foram implementadas para garantir um projeto fidedigno e seguro. O projeto apresentado está atualmente em preparação para produção na empresa Orthos XXI, depois do qual se seguem os ensaios mecânicos obrigatórios

    Biologically Inspired Legs and Novel Flow Control Valve Toward a New Approach for Accessible Wearable Robotics

    Get PDF
    The Humanoid Walking Robot (HWR) is a research platform for the study of legged and wearable robots actuated with Hydro Muscles. The fluid operated HWR is representative of a class of biologically inspired, and in some aspects highly biomimetic robotic musculoskeletal appendages showing certain advantages in comparison to more conventional artificial limbs and braces for physical therapy/rehabilitation, assistance of daily living, and augmentation. The HWR closely mimics the human body structure and function, including the skeleton, ligaments, tendons, and muscles. The HWR can emulate close to human-like movements even when subjected to simplified control laws. One of the main drawbacks of this approach is the inaccessibility of an appropriate fluid flow management support system, in the form of affordable, lightweight, compact, and good quality valves suitable for robotics applications. To resolve this shortcoming, the Compact Robotic Flow Control Valve (CRFC Valve) is introduced and successfully proof-of-concept tested. The HWR added with the CRFC Valve has potential to be a highly energy efficient, lightweight, controllable, affordable, and customizable solution that can resolve single muscle action

    Motor Electrical Damping for Back-Drivable Prosthetic Knee

    Get PDF
    The paper presents a model and analysis of a backdrivable knee prosthesis. In this context, the investigation into the design, modelling and analysis of a back-drivable semiactive prosthetic knee is presented. A mathematical model has been developed for evaluating the electrical damping characteristics of the DC motor in passive mode. The analysis shows that a single actuator could be suitable to work in active mode to provide mechanical power and in passive mode as a damper dissipating energy
    corecore