66,603 research outputs found

    Comparison of a prototype for indications-based prescribing with 2 commercial prescribing systems

    Get PDF
    Importance: The indication (reason for use) for a medication is rarely included on prescriptions despite repeated recommendations to do so. One barrier has been the way existing electronic prescribing systems have been designed. Objective: To evaluate, in comparison with the prescribing modules of 2 leading electronic health record prescribing systems, the efficiency, error rate, and satisfaction with a new computerized provider order entry prototype for the outpatient setting that allows clinicians to initiate prescribing using the indication. Design, Setting, and Participants: This quality improvement study used usability tests requiring internal medicine physicians, residents, and physician assistants to enter prescriptions electronically, including indication, for 8 clinical scenarios. The tool order assignments were randomized and prescribers were asked to use the prototype for 4 of the scenarios and their usual system for the other 4. Time on task, number of clicks, and order details were captured. User satisfaction was measured using posttask ratings and a validated system usability scale. The study participants practiced in 2 health systems\u27 outpatient practices. Usability tests were conducted between April and October of 2017. Main Outcomes and Measures: Usability (efficiency, error rate, and satisfaction) of indications-based computerized provider order entry prototype vs the electronic prescribing interface of 2 electronic health record vendors. Results: Thirty-two participants (17 attending physicians, 13 residents, and 2 physician assistants) used the prototype to complete 256 usability test scenarios. The mean (SD) time on task was 1.78 (1.17) minutes. For the 20 participants who used vendor 1\u27s system, it took a mean (SD) of 3.37 (1.90) minutes to complete a prescription, and for the 12 participants using vendor 2\u27s system, it took a mean (SD) of 2.93 (1.52) minutes. Across all scenarios, when comparing number of clicks, for those participants using the prototype and vendor 1, there was a statistically significant difference from the mean (SD) number of clicks needed (18.39 [12.62] vs 46.50 [27.29]; difference, 28.11; 95% CI, 21.47-34.75; P \u3c .001). For those using the prototype and vendor 2, there was also a statistically significant difference in number of clicks (20.10 [11.52] vs 38.25 [19.77]; difference, 18.14; 95% CI, 11.59-24.70; P \u3c .001). A blinded review of the order details revealed medication errors (eg, drug-allergy interactions) in 38 of 128 prescribing sessions using a vendor system vs 7 of 128 with the prototype. Conclusions and Relevance: Reengineering prescribing to start with the drug indication allowed indications to be captured in an easy and useful way, which may be associated with saved time and effort, reduced medication errors, and increased clinician satisfaction

    Comparison of a prototype for indications-based prescribing with 2 commercial prescribing systems

    Get PDF
    Importance: The indication (reason for use) for a medication is rarely included on prescriptions despite repeated recommendations to do so. One barrier has been the way existing electronic prescribing systems have been designed. Objective: To evaluate, in comparison with the prescribing modules of 2 leading electronic health record prescribing systems, the efficiency, error rate, and satisfaction with a new computerized provider order entry prototype for the outpatient setting that allows clinicians to initiate prescribing using the indication. Design, Setting, and Participants: This quality improvement study used usability tests requiring internal medicine physicians, residents, and physician assistants to enter prescriptions electronically, including indication, for 8 clinical scenarios. The tool order assignments were randomized and prescribers were asked to use the prototype for 4 of the scenarios and their usual system for the other 4. Time on task, number of clicks, and order details were captured. User satisfaction was measured using posttask ratings and a validated system usability scale. The study participants practiced in 2 health systems\u27 outpatient practices. Usability tests were conducted between April and October of 2017. Main Outcomes and Measures: Usability (efficiency, error rate, and satisfaction) of indications-based computerized provider order entry prototype vs the electronic prescribing interface of 2 electronic health record vendors. Results: Thirty-two participants (17 attending physicians, 13 residents, and 2 physician assistants) used the prototype to complete 256 usability test scenarios. The mean (SD) time on task was 1.78 (1.17) minutes. For the 20 participants who used vendor 1\u27s system, it took a mean (SD) of 3.37 (1.90) minutes to complete a prescription, and for the 12 participants using vendor 2\u27s system, it took a mean (SD) of 2.93 (1.52) minutes. Across all scenarios, when comparing number of clicks, for those participants using the prototype and vendor 1, there was a statistically significant difference from the mean (SD) number of clicks needed (18.39 [12.62] vs 46.50 [27.29]; difference, 28.11; 95% CI, 21.47-34.75; P \u3c .001). For those using the prototype and vendor 2, there was also a statistically significant difference in number of clicks (20.10 [11.52] vs 38.25 [19.77]; difference, 18.14; 95% CI, 11.59-24.70; P \u3c .001). A blinded review of the order details revealed medication errors (eg, drug-allergy interactions) in 38 of 128 prescribing sessions using a vendor system vs 7 of 128 with the prototype. Conclusions and Relevance: Reengineering prescribing to start with the drug indication allowed indications to be captured in an easy and useful way, which may be associated with saved time and effort, reduced medication errors, and increased clinician satisfaction

    Refining Computerized Physician Order Entry Initiatives in an Adult Intensive Care Unit

    Get PDF
    Computerized physician order entry (CPOE) is used in healthcare organizations to improve workflow processes and transcription, as well as to prevent prescribing errors. Previous research has indicated challenges associated with CPOE for end-users that predispose patients to unsafe practices. Unsafe CPOE practices can be detrimental within the intensive care unit (ICU) setting due to the complexity of nursing care. Consequently, end-user satisfaction and understanding of CPOE and electronic health record (EHR) functionality are vital to avoid error omissions. CPOE initiatives should be refined post system implementation to improve clinical workflow, medication processes, and end-user satisfaction. The purpose of this quality improvement project was to refine CPOE system initiatives and develop an e-learning educational module to facilitate end-user understanding of and satisfaction with CPOE. The Iowa model of evidence-based practice, Lean methodology, and Provider Order Entry User Satisfaction and Usage Survey (POESUS) were used to guide the study. An e-learning module was implemented to increase staff understanding of the newly implemented CPOE system, and a plan was provided for ongoing data collection and investigation of end-user satisfaction and medication inadequacies with the CPOE system. A mixed-method design was recommended to key stakeholders to identify the impact of the e-learning course and refined CPOE initiatives on both end-user satisfaction and patient outcomes in the medical-surgical ICU. Findings from the study informed the impact of e-learning educational modules with CPOE system implementation. Those in organizations implementing advanced technology such as CPOE and EHR systems in critical care settings will find this paper of interest

    Improving Access to Improve Quality: Evaluation of an Organizational Innovation

    Get PDF
    Reviews the Group Health Cooperative's 2002 adoption of a patient-centered model giving enrollees choices of and direct access to doctors, with a patient Web site, productivity and quality incentives for doctors, and a cost-efficient primary care system

    Annotated Bibliography: Understanding Ambulatory Care Practices in the Context of Patient Safety and Quality Improvement.

    Get PDF
    The ambulatory care setting is an increasingly important component of the patient safety conversation. Inpatient safety is the primary focus of the vast majority of safety research and interventions, but the ambulatory setting is actually where most medical care is administered. Recent attention has shifted toward examining ambulatory care in order to implement better health care quality and safety practices. This annotated bibliography was created to analyze and augment the current literature on ambulatory care practices with regard to patient safety and quality improvement. By providing a thorough examination of current practices, potential improvement strategies in ambulatory care health care settings can be suggested. A better understanding of the myriad factors that influence delivery of patient care will catalyze future health care system development and implementation in the ambulatory setting

    Role of Computerized Physician Order Entry Usability in the Reduction of Prescribing Errors

    Get PDF
    Some hospitals have implemented computerized physician order entry (CPOE) systems to reduce the medical error rates. However, research in this area has been very limited, especially regarding the impact of CPOE use on the reduction of prescribing errors. Moreover, the past studies have dealt with the overall impact of CPOE on the reduction of broadly termed "medical errors", and they have not specified which medical errors have been reduced by CPOE. Furthermore, the majority of the past research in this field has been either qualitative or has not used robust empirical techniques. This research examined the impacts of usability of CPOE systems on the reduction of doctors' prescribing errors. Methods: One hundred and sixty-six questionnaires were used for quantitative data analyses. Since the data was not normally distributed, partial least square path modelling-as the second generation of multivariate data analyses-was applied to analyze data. Results: It was found that the ease of use of the system and information quality can significantly reduce prescribing errors. Moreover, the user interface consistency and system error prevention have a significant positive impact on the perceived ease of use. More than 50% of the respondents believed that CPOE reduces the likelihood of drug allergy, drug interaction, and drug dosing errors thus improving patient safety. Conclusions: Prescribing errors in terms of drug allergy, drug interaction, and drug dosing errors are reduced if the CPOE is not error-prone and easy to use, if the user interface is consistent, and if it provides quality information to doctors

    Organizing for Higher Performance: Case Studies of Organized Delivery Systems

    Get PDF
    Offers lessons learned from healthcare delivery systems promoting the attributes of an ideal model as defined by the Fund: information continuity, care coordination and transitions, system accountability, teamwork, continuous innovation, and easy access

    Organizing the U.S. Health Care Delivery System for High Performance

    Get PDF
    Analyzes the fragmentation of the healthcare delivery system and makes policy recommendations -- including payment reform, regulatory changes, and infrastructure -- for creating mechanisms to coordinate care across providers and settings

    Acceptance model of electronic medical record

    Get PDF
    This paper discusses acceptance issues of Electronic Medical Record System (EMR), particularly in Malaysia. A detailed overview of EMR and its benefits are firstly discussed. A number of acceptance models are scrutinized. Then factors affecting EMR acceptance are put forward. Finally, before proposing an EMR acceptance model, an instrument formed by adapting and then finding its factors loading is presented
    • …
    corecore