21 research outputs found

    Active exoskeleton control systems: State of the art

    Get PDF
    To get a compliant active exoskeleton controller, the force interaction controllers are mostly used in form of either the impedance or admittance controllers. The impedance or admittance controllers can only work if they are followed by either the force or the position controller respectively. These combinations place the impedance or admittance controller as high-level controller while the force or position controller as low-level controller. From the application point of view, the exoskeleton controllers are equipped by task controllers that can be formed in several ways depend on the aims. This paper presents the review of the control systems in the existing active exoskeleton in the last decade. The exoskeleton control system can be categorized according to the model system, the physical parameters, the hierarchy and the usage. These considerations give different control schemes. The main consideration of exoskeleton control design is how to achieve the best control performances. However, stability and safety are other important issues that have to be considered. © 2012 The Authors

    ระบบควบคุมแบบไฮบริดโดยอิงแรงและสัญญาณไฟฟ้ากล้ามเนื้อสำหรับหุ่นยนต์ทำกายภาพบำบัด

    Get PDF
    This paper presents a hybrid control system of rehabilitation robot with force and EMG signals. The proposed control system is implemented on the elbow joint of the 4 DOF universal exoskeleton. Admittance control method is applied to control this rehabilitation robot. However, the transient response of the admittance control cloud lead in a large overshoot when the user moves exoskeleton joint quickly then suddenly stops. Hence, the EMG sensor is used to detect the muscle contraction and then the force input will be set to zero for improving transient response of the hybrid controller. Furthermore, the generalized regression neural network (GRNN) is applied for predicting the static gravity force compensation. The experimental result indicates that the GRNN can predict the static gravity force with accuracy of 97.32%. Moreover, 83.13% of the transient response is improved by the utilization of the EMG signal in the hybrid controller

    A sEMG-driven Musculoskeletal Model to Control Exoskeleton Robot Used in Lower Extremity Rehabilitation

    Get PDF
    A control system framework of lower extremity rehabilitation exoskeleton robot is presented. It is based on the Neuro-Musculo-Skeletal biological model. Its core composition module, the motion intent parser part, mainly comprises of three distinct parts. The first part is signal acquisition of surface electromyography (sEMG) that is the summation of motor unit action potential (MUAP) starting from central nervous system (CNS).sEMG can be used to decode action intent of operator to make the patient actively participate in specific training .As another composition part, a muscle dynamics model that is comprised of activation and contraction dynamic model is developed. It is mainly used to calculate muscle force. The last part is the skeletal dynamic model that is simplified as a linked segment mechanics. Combined with muscle dynamic model, the joint torque exerted by internal muscles can be exported, which can be used to do a exoskeleton controller design. The developed control framework can make exoskeleton offer assistance to operators during rehabilitation by guiding motions on correct training rehabilitation trajectories, or give force support to be able to perform certain motions. Though the presentation is orientated towards the lower extremity exoskeleton, it is generic and can be applied to almost any part of the human body

    Assistive control system using continuous myoelectric signal in robot-aided arm training for patients after stroke

    Get PDF
    Author name used in this publication: Kai-yu Tong2008-2009 > Academic research: refereed > Publication in refereed journalVersion of RecordPublishe

    Model-based myoelectric control of robots for assistance and rehabilitation

    Get PDF
    The first anthropomorphic robots and exoskeletons were developed with the idea of combining man and machine into an intimate symbiotic unit that can perform as one joint system. A human-robot interface consists of processes of two different nature: (1) the physical interaction (pHRI) between the device and its user and (2) the exchange of cognitive information (cHRI) between the human and the robot. To achieve the symbiosis between the two actors, both need to be optimized. The evolution of mechanical design and the introduction of new materials pushed pHRI to new frontiers on ergonomics and assistance performance. However, cHRI still lacks on this direction because is more complicated: it requires communication from the cognitive processes occuring in the human agent to the robot, e.g. intention detection; but also from the robot to the human agent, e.g. feedback modalities such as haptic cues. A possible innovation is the inclusion of the electromyographic signal, the command signal from our brain to the musculoskeletal system for the movement, in the robot control loop. The aim of this thesis was to develop a real-time control framework for an assistive device that can generate the same force produced by the muscles. To do this, I incorporated in the robot control loop a detailed musculoskeletal model that estimates the net torque at the joint level by taking as inputs the electromyography signals and kinematic data. This module is called myoprocessor. Here I present two applications of this control approach: the first was implemented on a soft wearable arm exosuit in order to evaluate the adaptation of the controller on different motion and loads. The second one, was a generation of myoprocessor-driven force field on a planar robot manipulandum in order to study the modularity changes of the musculoskeletal system. Both applications showed that the device controlled by myoprocessor works symbiotically with the user, by reducing the muscular activity and preserving the motor performance. The ability of seamlessly combining musculoskeletal force estimators with assistive devices opens new avenues for assisting human movement both in healthy and impaired individuals

    Application of Artificial Intelligence (AI) in Prosthetic and Orthotic Rehabilitation

    Get PDF
    Technological integration of Artificial Intelligence (AI) and machine learning in the Prosthetic and Orthotic industry and in the field of assistive technology has become boon for the Persons with Disabilities. The concept of neural network has been used by the leading manufacturers of rehabilitation aids for simulating various anatomical and biomechanical functions of the lost parts of the human body. The involvement of human interaction with various agents’ i.e. electronic circuitry, software, robotics, etc. has made a revolutionary impact in the rehabilitation field to develop devices like Bionic leg, mind or thought control prosthesis and exoskeletons. Application of Artificial Intelligence and robotics technology has a huge impact in achieving independent mobility and enhances the quality of life in Persons with Disabilities (PwDs)

    Development of Digital Control Systems for Wearable Mechatronic Devices: Applications in Musculoskeletal Rehabilitation of the Upper Limb

    Get PDF
    The potential for wearable mechatronic systems to assist with musculoskeletal rehabilitation of the upper limb has grown with the technology. One limiting factor to realizing the benefits of these devices as motion therapy tools is within the development of digital control solutions. Despite many device prototypes and research efforts in the surrounding fields, there are a lack of requirements, details, assessments, and comparisons of control system characteristics, components, and architectures in the literature. Pairing this with the complexity of humans, the devices, and their interactions makes it a difficult task for control system developers to determine the best solution for their desired applications. The objective of this thesis is to develop, evaluate, and compare control system solutions that are capable of tracking motion through the control of wearable mechatronic devices. Due to the immaturity of these devices, the design, implementation, and testing processes for the control systems is not well established. In order to improve the efficiency and effectiveness of these processes, control system development and evaluation tools have been proposed. The Wearable Mechatronics-Enabled Control Software framework was developed to enable the implementation and comparison of different control software solutions presented in the literature. This framework reduces the amount of restructuring and modification required to complete these development tasks. An integration testing protocol was developed to isolate different aspects of the control systems during testing. A metric suite is proposed that expands on the existing literature and allows for the measurement of more control characteristics. Together, these tools were used ii ABSTRACT iii to developed, evaluate, and compare control system solutions. Using the developed control systems, a series of experiments were performed that involved tracking elbow motion using wearable mechatronic elbow devices. The accuracy and repeatability of the motion tracking performances, the adaptability of the control models, and the resource utilization of the digital systems were measured during these experiments. Statistical analysis was performed on these metrics to compare between experimental factors. The results of the tracking performances show some of the highest accuracies for elbow motion tracking with these devices. The statistical analysis revealed many factors that significantly impact the tracking performance, such as visual feedback, motion training, constrained motion, motion models, motion inputs, actuation components, and control outputs. Furthermore, the completion of the experiments resulted in three first-time studies, such as the comparison of muscle activation models and the quantification of control system task timing and data storage needs. The successes of these experiments highlight that accurate motion tracking, using biological signals of the user, is possible, but that many more efforts are needed to obtain control solutions that are robust to variations in the motion and characteristics of the user. To guide the future development of these control systems, a national survey was conducted of therapists regarding their patient data collection and analysis methods. From the results of this survey, a series of requirements for software systems, that allow therapists to interact with the control systems of these devices, were collected. Increasing the participation of therapists in the development processes of wearable assistive devices will help to produce better requirements for developers. This will allow the customization of control systems for specific therapies and patient characteristics, which will increase the benefit and adoption rate of these devices within musculoskeletal rehabilitation programs

    Current state of digital signal processing in myoelectric interfaces and related applications

    Get PDF
    This review discusses the critical issues and recommended practices from the perspective of myoelectric interfaces. The major benefits and challenges of myoelectric interfaces are evaluated. The article aims to fill gaps left by previous reviews and identify avenues for future research. Recommendations are given, for example, for electrode placement, sampling rate, segmentation, and classifiers. Four groups of applications where myoelectric interfaces have been adopted are identified: assistive technology, rehabilitation technology, input devices, and silent speech interfaces. The state-of-the-art applications in each of these groups are presented.Peer reviewe
    corecore